《ASTM E1033-2013 red 9340 Standard Practice for Electromagnetic (Eddy Current) Examination of Type F-Continuously Welded (CW) Ferromagnetic Pipe and Tubing Above the Curie Temperatu.pdf》由会员分享,可在线阅读,更多相关《ASTM E1033-2013 red 9340 Standard Practice for Electromagnetic (Eddy Current) Examination of Type F-Continuously Welded (CW) Ferromagnetic Pipe and Tubing Above the Curie Temperatu.pdf(4页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: E1033 09E1033 13Standard Practice forElectromagnetic (Eddy-Current) (Eddy Current) Examinationof TypeF-Continuously Welded (CW) Ferromagnetic Pipe andTubing Above the Curie Temperature1This standard is issued under the fixed designation E1033; the number immediately following the design
2、ation indicates the year oforiginal adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope Scope*1.1 This practice covers a pr
3、ocedure for in-line, eddy-current eddy current examination of continuously welded (CW)ferromagnetic pipe and tubing at temperatures above the Curie temperature (approximately 1400F (760C), where the pipe issubstantially nonmagnetic or austenitic.1.2 This practice is intended for use on tubular produ
4、cts having nominal diameters of 12 in. (12.7 mm) to 4 in. (101.6 mm).These techniques may be used for larger- or smaller-diameter pipe and tubing as specified by the using parties.1.3 This practice is specifically applicable to eddy-current examination eddy current testing using encircling coils, or
5、 probecoils.1.4 This practice does not establish acceptance criteria. They must be established by the using parties.1.5 UnitsThe values stated in inch-pound units are to be regarded as the standard. The values given in parentheses aremathematical conversions to SI units that are provided for informa
6、tion only and are not considered standard.1.6 This standard does not purport to address the safety problems associated with its use. It is the responsibility of the user ofthis standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations pri
7、orto use.2. Referenced Documents2.1 ASTM Standards:2E309 Practice for Eddy-Current Examination of Steel Tubular Products Using Magnetic SaturationE543 Specification for Agencies Performing Nondestructive TestingE1316 Terminology for Nondestructive Examinations2.2 Other Documents:SNT-TC-1A Recommende
8、d Practice for Personnel Qualification and Certification in Nondestructive Testing3ANSI/ASNT-CP-189 ASNT Standard for Qualification and Certification of Nondestructive Testing Personnel3NAS-410 NAS Certification and Qualification of Nondestructive Personnel (Quality Assurance Committee)43. Terminolo
9、gy3.1 Standard terminology relating to electromagnetic examinationtesting may be found in Terminology E1316, Section C,Electromagnetic Testing.4. Summary of Practice4.1 In-line, automatic, eddy-current eddy current examination of CW pipe utilizes probes or encircling coils, or both, mountedin the pa
10、ss line to monitor the quality of pipe during production at temperatures ranging from 1600 to 2200F (870 to 1204C).1 This practice is under the jurisdiction of ASTM Committee E07 on Nondestructive Testing and is the direct responsibility of Subcommittee E07.07 on ElectromagneticMethod.Current editio
11、n approved June 1, 2009Dec. 1, 2013. Published July 2009December 2013. Originally approved in 1985. Last previous edition approved in 20042009 asE1033 - 98E1033 - 09.(2004)1 . DOI: 10.1520/E1033-09.10.1520/E1033-13.2 For referencedASTM standards, visit theASTM website, www.astm.org, or contactASTM C
12、ustomer Service at serviceastm.org. For Annual Book of ASTM Standardsvolume information, refer to the standards Document Summary page on the ASTM website.3 Available from American Society for Nondestructive Testing (ASNT), P.O. Box 28518, 1711 Arlingate Ln., Columbus, OH 43228-0518, http:/www.asnt.o
13、rg.4 Available from Aerospace Industries Association of America, Inc. (AIA), 1000 Wilson Blvd., Suite 1700, Arlington, VA 22209-3928, http:/www.aia-aerospace.org.This document is not an ASTM standard and is intended only to provide the user of an ASTM standard an indication of what changes have been
14、 made to the previous version. Becauseit may not be technically possible to adequately depict all changes accurately, ASTM recommends that users consult prior editions as appropriate. In all cases only the current versionof the standard as published by ASTM is to be considered the official document.
15、*A Summary of Changes section appears at the end of this standardCopyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States14.2 Eddy-current Eddy current instrumentation provides timely and useful information regarding the acceptability of CW pi
16、pefor quality control purposes as well as for early warning that unacceptable pipe is being produced.5. Significance and Use5.1 The purpose of this practice is to outline a procedure for the in-line eddy-current eddy current examination of hot CW pipefor the detection of major imperfections and repe
17、titive discontinuities.5.2 Amajor advantage of in-line eddy-current eddy current examination of ferromagnetic CW pipe above the Curie temperaturelies in the enhanced signal-to-noise ratio and depth of penetration obtained without the use of magnetic saturation.5.3 The eddy-current eddy current metho
18、d is capable of detecting and locating weld imperfections commonly referred to as openwelds, cave welds, black spots (weld inclusions), and partial welds (incomplete penetration). In addition, it will detect pipe-wallimperfections such as slivers, laps, and ring welds (end welds).5.4 The relative se
19、verity of the imperfections may be indicated by eddy-current eddy current signal amplitude or phase, or both.An alarm level may be selected that utilizes signal amplitude or phase, or both, for automatic recording or marking, or both.5.5 Because the responses from natural discontinuities may vary si
20、gnificantly from those from artificial discontinuities, caremust be exercised in establishing test sensitivity and acceptance criteria.6. Basis of Application6.1 The following criteria may be specified in the purchase specification, contractual agreement, or elsewhere, and may requireagreement betwe
21、en the purchaser and the supplier.6.1.1 The diameter, wall-thickness, and temperature of the pipe being examined.6.1.2 The extent of the examination.6.1.3 The time of examination: the point or points in the manufacturing process where the pipe will be examined, and itsthroughput speed.6.1.4 Test Sta
22、ndardization:6.1.4.1 The size (length, diameter, and wall) and composition of the reference standard if applicable.6.1.4.2 The time between calibrationstandardization checks.6.1.5 The disposition of material with indications.6.1.6 The reporting of testexamination results.6.1.7 If specified in the co
23、ntractual agreement, personnel performing examinations to this practice shall be qualified inaccordance with a nationally recognized NDT personnel qualification practice or standard such as ANSI/ASNT-CP-189,SNT-TC-1A, MIL-STD-410E, NAS-410,ASNT-ACCP, or a similar document and certified by the certif
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTME10332013RED9340STANDARDPRACTICEFORELECTROMAGNETICEDDYCURRENTEXAMINATIONOFTYPEFCONTINUOUSLYWELDEDCWFERROMAGNETICPIPEANDTUBINGABOVETHECURIETEMPERATUPDF

链接地址:http://www.mydoc123.com/p-527774.html