ASTM E1033-2009 895 Standard Practice for Electromagnetic (Eddy-Current) Examination of Type F-Continuously Welded (CW) Ferromagnetic Pipe and Tubing Above the Curie Temperature《在居.pdf
《ASTM E1033-2009 895 Standard Practice for Electromagnetic (Eddy-Current) Examination of Type F-Continuously Welded (CW) Ferromagnetic Pipe and Tubing Above the Curie Temperature《在居.pdf》由会员分享,可在线阅读,更多相关《ASTM E1033-2009 895 Standard Practice for Electromagnetic (Eddy-Current) Examination of Type F-Continuously Welded (CW) Ferromagnetic Pipe and Tubing Above the Curie Temperature《在居.pdf(3页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: E 1033 09Standard Practice forElectromagnetic (Eddy-Current) Examination of TypeF-Continuously Welded (CW) Ferromagnetic Pipe andTubing Above the Curie Temperature1This standard is issued under the fixed designation E 1033; the number immediately following the designation indicates the
2、year oforiginal adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope1.1 This practice covers a procedure for in-line, eddy-c
3、urrent examination of continuously welded (CW) ferromag-netic pipe and tubing at temperatures above the Curie tempera-ture (approximately 1400F (760C), where the pipe issubstantially nonmagnetic or austenitic.1.2 This practice is intended for use on tubular productshaving nominal diameters of12 in.
4、(12.7 mm) to 4 in. (101.6mm). These techniques may be used for larger- or smaller-diameter pipe and tubing as specified by the using parties.1.3 This practice is specifically applicable to eddy-currentexamination using encircling coils, or probe coils.1.4 This practice does not establish acceptance
5、criteria.They must be established by the using parties.1.5 The values stated in inch-pound units are to be regardedas the standard. The values given in parentheses are mathemati-cal conversions to SI units that are provided for informationonly and are not considered standard.1.6 This standard does n
6、ot purport to address the safetyproblems associated with its use. It is the responsibility of theuser of this standard to establish appropriate safety and healthpractices and determine the applicability of regulatory limita-tions prior to use.2. Referenced Documents2.1 ASTM Standards:2E 309 Practice
7、 for Eddy-Current Examination of Steel Tu-bular Products Using Magnetic SaturationE 543 Specification for Agencies Performing Nondestruc-tive TestingE 1316 Terminology for Nondestructive Examinations2.2 Other Documents:SNT-TC-1A Recommended Practice for Personnel Qualifi-cation and Certification in
8、Nondestructive Testing3ANSI/ASNT-CP-189 ASNT Standard for Qualification andCertification of Nondestructive Testing Personnel3NAS-410 NAS Certification and Qualification of Nonde-structive Personnel (Quality Assurance Committee)43. Terminology3.1 Standard terminology relating to electromagnetic ex-am
9、ination may be found in Terminology E 1316, Section C,Electromagnetic Testing.4. Summary of Practice4.1 In-line, automatic, eddy-current examination of CWpipe utilizes probes or encircling coils, or both, mounted in thepass line to monitor the quality of pipe during production attemperatures ranging
10、 from 1600 to 2200F (870 to 1204C).4.2 Eddy-current instrumentation provides timely and use-ful information regarding the acceptability of CW pipe forquality control purposes as well as for early warning thatunacceptable pipe is being produced.5. Significance and Use5.1 The purpose of this practice
11、is to outline a procedure forthe in-line eddy-current examination of hot CW pipe for thedetection of major imperfections and repetitive discontinuities.5.2 A major advantage of in-line eddy-current examinationof ferromagnetic CW pipe above the Curie temperature lies inthe enhanced signal-to-noise ra
12、tio and depth of penetrationobtained without the use of magnetic saturation.5.3 The eddy-current method is capable of detecting andlocating weld imperfections commonly referred to as openwelds, cave welds, black spots (weld inclusions), and partialwelds (incomplete penetration). In addition, it will
13、 detectpipe-wall imperfections such as slivers, laps, and ring welds(end welds).5.4 The relative severity of the imperfections may beindicated by eddy-current signal amplitude or phase, or both.1This practice is under the jurisdiction of ASTM Committee E07 on Nonde-structive Testing and is the direc
14、t responsibility of Subcommittee E07.07 onElectromagnetic Method.Current edition approved June 1, 2009. Published July 2009. Originally approvedin 1985. Last previous edition approved in 2004 as E 1033 - 98(2004)1.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM C
15、ustomer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.3Available fromAmerican Society for Nondestructive Testing (ASNT), P.O. Box28518, 1711 Arlingate Ln., Columbus, OH 43228-0518, http:/www.asnt.org.4
16、Available from Aerospace Industries Association of America, Inc. (AIA), 1000Wilson Blvd., Suite 1700,Arlington, VA22209-3928, http:/www.aia-aerospace.org.1Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.An alarm level may be selected
17、that utilizes signal amplitude orphase, or both, for automatic recording or marking, or both.5.5 Because the responses from natural discontinuities mayvary significantly from those from artificial discontinuities,care must be exercised in establishing test sensitivity andacceptance criteria.6. Basis
18、 of Application6.1 The following criteria may be specified in the purchasespecification, contractual agreement, or elsewhere, and mayrequire agreement between the purchaser and the supplier.6.1.1 The diameter, wall-thickness, and temperature of thepipe being examined.6.1.2 The extent of the examinat
19、ion.6.1.3 The time of examination: the point or points in themanufacturing process where the pipe will be examined, andits throughput speed.6.1.4 Test Standardization:6.1.4.1 The size (length, diameter, and wall) and composi-tion of the reference standard if applicable.6.1.4.2 The time between calib
20、ration checks.6.1.5 The disposition of material with indications.6.1.6 The reporting of test results.6.1.7 If specified in the contractual agreement, personnelperforming examinations to this practice shall be qualified inaccordance with a nationally recognized NDT personnel quali-fication practice o
21、r standard such as ANSI/ASNT-CP-189,SNT-TC-1A, MIL-STD-410E, NAS-410, ASNT-ACCP, or asimilar document and certified by the certifying agency, asapplicable. The practice or standard used and its applicablerevision shall be identified in the contractual agreement be-tween the using parties.NOTE 1MIL-S
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTME10332009895STANDARDPRACTICEFORELECTROMAGNETICEDDYCURRENTEXAMINATIONOFTYPEFCONTINUOUSLYWELDEDCWFERROMAGNETICPIPEANDTUBINGABOVETHECURIETEMPERATURE

链接地址:http://www.mydoc123.com/p-527773.html