《ASTM D8210-2018 5625 Standard Test Method for Automatic Determination of Low-Temperature Viscosity of Automatic Transmission Fluids Hydraulic Fluids and Lubricants Using a Rotation.pdf》由会员分享,可在线阅读,更多相关《ASTM D8210-2018 5625 Standard Test Method for Automatic Determination of Low-Temperature Viscosity of Automatic Transmission Fluids Hydraulic Fluids and Lubricants Using a Rotation.pdf(11页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: D8210 18Standard Test Method forAutomatic Determination of Low-Temperature Viscosity ofAutomatic Transmission Fluids, Hydraulic Fluids, andLubricants Using a Rotational Viscometer1This standard is issued under the fixed designation D8210; the number immediately following the designation
2、 indicates the year oforiginal adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope1.1 This test method automates the determ
3、ination of lowtemperature, low-shear-rate viscosity of driveline and hydrau-lic fluids, such as automatic transmission fluids, gear oils,hydraulic fluids, and other lubricants. It utilizes a thermoelec-trically temperature-controlled sample chamber along with aprogrammable rotational viscometer. Thi
4、s test method covers aviscosity range of 300 mPas to 900 000 mPas measured attemperatures from 40 C to 10 C.1.2 The precision data were determined at 40 C and26 C for a viscosity range of 6380 mPas to 255 840 mPas.1.3 The values stated in SI units are to be regarded asstandard. No other units of mea
5、surement are included in thisstandard except those noted below.1.3.1 ExceptionThe test method uses the SI unit,milliPascal-second (mPas), as the unit of viscosity. (1 cP =1 mPas).1.4 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is therespon
6、sibility of the user of this standard to establish appro-priate safety, health, and environmental practices and deter-mine the applicability of regulatory limitations prior to use.1.5 This international standard was developed in accor-dance with internationally recognized principles on standard-izat
7、ion established in the Decision on Principles for theDevelopment of International Standards, Guides and Recom-mendations issued by the World Trade Organization TechnicalBarriers to Trade (TBT) Committee.2. Referenced Documents2.1 ASTM Standards:2D341 Practice for Viscosity-Temperature Charts for Liq
8、uidPetroleum ProductsD2983 Test Method for Low-Temperature Viscosity of Au-tomatic Transmission Fluids, Hydraulic Fluids, and Lubri-cants using a Rotational ViscometerD5293 Test Method for Apparent Viscosity of Engine Oilsand Base Stocks Between 10 C and 35 C UsingCold-Cranking SimulatorD6708 Practi
9、ce for Statistical Assessment and Improvementof Expected Agreement Between Two Test Methods thatPurport to Measure the Same Property of a MaterialD7962 Practice for Determination of Minimum ImmersionDepth and Assessment of Temperature Sensor Measure-ment DriftE644 Test Methods for Testing Industrial
10、 Resistance Ther-mometersE2877 Guide for Digital Contact Thermometers2.2 ISO Standard:3ISO 17025 General requirements for the competence oftesting and calibration laboratories3. Terminology3.1 Definitions:3.1.1 digital contact thermometer (DCT), nan electronicdevice consisting of a digital display a
11、nd associated tempera-ture sensing probe.3.1.1.1 DiscussionThis device consists of a temperaturesensor connected to a measuring instrument; this instrumentmeasures the temperature-dependent quantity of the sensor,computes the temperature from the measured quantity, andprovides a digital output. This
12、 digital output goes to a digitaldisplay and/or recording device that may be internal or externalto the device. These devices are referred to as “digitalthermometers.”3.1.1.2 DiscussionPET is an acronym for portable elec-tronic thermometer, a subset of digital contact thermometers(DCT).1This test me
13、thod is under the jurisdiction of ASTM Committee D02 onPetroleum Products, Liquid Fuels, and Lubricants and is the direct responsibility ofSubcommittee D02.07 on Flow Properties.Current edition approved July 1, 2018. Published September 2018. DOI:10.1520/D8210-18.2For referenced ASTM standards, visi
14、t the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.3Available from American National Standards Institute (ANSI), 25 W. 43rd St.,4th Floor, New York,
15、 NY 10036, http:/www.ansi.org.Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United StatesThis international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principl
16、es for theDevelopment of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.13.2 Definitions of Terms Specific to This Standard:3.2.1 reference viscosity, nthe viscosity of Newtonianreference fluid whose values were
17、determined by the use of amaster viscometer at one or more temperatures.3.2.2 test chamber retaining ring, ncone-shaped collarthat secures the sample tube in the test chamber.3.2.3 viscometer retaining ring, nthe collar that holds theviscometer in position on the viscometer tray.3.2.4 viscometer tra
18、y, nthe support platform on which theviscometer is mounted.4. Summary of Test Method4.1 A 20 mL sample of the test fluid is heated to 50 C andheld there for 30 min before cooling it to room temperature.This is followed by cooling in a prescribed manner that mimicsa sample cooling in an air bath to t
19、he test temperature, whichfollows Newtons Cooling Law. This thermal conditioning isconsistent with that described in the Annex of Test MethodD2983. The equation with the constants used are noted inAnnex A1. The sample is cooled to test temperature in 1.7 h,then held there for 14 h before the viscosi
20、ty is measured witha specific insulated spindle at specific series of shear rates(rotational speeds). When the viscosity measurements arecomplete, the sample chamber is returned to room temperature.4.2 This test method includes an abbreviated thermal con-ditioning program, Option B, which is based o
21、n the referencein the 1987 and earlier versions of Test Method D2983. Thisabbreviated program reduces to 4 h the time the sample is heldat test temperature before beginning viscosity measurement.Since the time at test temperature is less for this option, themeasured viscosity may be lower than the n
22、ormal length test,Option A, noted in 4.1.4.3 From the beginning of a test until viscosity measure-ments are complete, the digital viscometer records elapsedtime, and sample temperature then during viscosity measure-ment it records, spindle speed, torque, and viscosity at 10 sintervals for 180 s at e
23、ach speed. At the end of test, a summaryof the viscosity data is displayed by the viscometer. For eachspindle speed, the summary contains an average viscosity forthe first 160 s and an average of 160 s to 180 s, which is the testresult. The test data can be printed or saved to a CSV(comma-separated
24、values) file, which provides a record to boththe thermal conditioning and viscosity measurements.4.4 In recognition of the fact that some samples comedirectly from the process line at temperatures near the preheattemperature of 50 C, Appendix X1 lists the program criterianeeded for either the full-l
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMD821020185625STANDARDTESTMETHODFORAUTOMATICDETERMINATIONOFLOWTEMPERATUREVISCOSITYOFAUTOMATICTRANSMISSIONFLUIDSHYDRAULICFLUIDSANDLUBRICANTSUSINGAROTATIONPDF

链接地址:http://www.mydoc123.com/p-526818.html