ASTM D7884-2013 5625 Standard Test Method for Determination of 4-Carboxybenzaldehyde and p-Toluic Acid in Purified Terephthalic Acid by Reverse Phase High Performance Liquid Chroma.pdf
《ASTM D7884-2013 5625 Standard Test Method for Determination of 4-Carboxybenzaldehyde and p-Toluic Acid in Purified Terephthalic Acid by Reverse Phase High Performance Liquid Chroma.pdf》由会员分享,可在线阅读,更多相关《ASTM D7884-2013 5625 Standard Test Method for Determination of 4-Carboxybenzaldehyde and p-Toluic Acid in Purified Terephthalic Acid by Reverse Phase High Performance Liquid Chroma.pdf(5页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: D7884 13Standard Test Method forDetermination of 4-Carboxybenzaldehyde and p-Toluic Acidin Purified Terephthalic Acid by Reverse Phase HighPerformance Liquid Chromatography1This standard is issued under the fixed designation D7884; the number immediately following the designation indica
2、tes the year oforiginal adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope1.1 This test method covers the determination of
3、 the4-Carboxybenzaldehyde (4-CBA) and p-Toluic acid (p-TOL)in purified terephthalic acid (PTA) by reverse phase highperformance liquid chromatography (HPLC). This method isapplicable for 4-CBAfrom 2 to 500 mg/kg and for p-TOL from10 to 500 mg/kg, respectively.1.2 In determining the conformance of th
4、e test results usingthis method to applicable specification, results shall be roundedoff in accordance with the rounding-off method of PracticeE29.1.3 The values stated in SI units are to be regarded asstandard. No other units of measurement are included in thisstandard.1.4 This standard does not pu
5、rport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use.2. Referenced Documents2.1 ASTM Standards:2D
6、1193 Specification for Reagent WaterD4790 Terminology of Aromatic Hydrocarbons and RelatedChemicalsD6809 Guide for Quality Control and Quality AssuranceProcedures for Aromatic Hydrocarbons and Related Ma-terialsE29 Practice for Using Significant Digits in Test Data toDetermine Conformance with Speci
7、ficationsE177 Practice for Use of the Terms Precision and Bias inASTM Test MethodsE682 Practice for Liquid Chromatography Terms and Rela-tionshipsE691 Practice for Conducting an Interlaboratory Study toDetermine the Precision of a Test Method2.2 ISO Document:3EN ISO 8213 Chemical products for indust
8、rial useSampling techniquesSolid chemical products in theform of particles varying from powders to coarse lumps2.3 Other Document:4OSHA Regulations, 29 CFR paragraphs 1910.1000 and1910.12003. Summary of Test Method3.1 Reverse Phase HPLC MethodPTAsample is dissolvedin ammonium hydroxide solution, and
9、 a fixed volume of thissolution is injected into a high performance liquid chromato-graph equipped with a UV detector. A C18 chemically bondedcolumn is used to separate the impurities 4-CBA and p-TOLfrom PTA. The external standard calibration is used forquantification.4. Significance and Use4.1 The
10、presence of 4-CBA and p-TOL in PTA used for theproduction of polyester is undesirable because they can slowdown the polymerization process and 4-CBA imparts color-ation to the polymer due to thermal instability.4.2 Determining the amount of 4-CBA and p-TOL remain-ing from the manufacture of PTA is o
11、ften required. This testmethod is suitable for setting specifications and for use as aninternal quality control tool where these products are producedor are used.5. Apparatus5.1 High Performance Liquid Chromatograph (HPLC)any HPLC capable of pumping the mobile phase at flow rates1This test method is
12、 under the jurisdiction of ASTM Committee D16 onAromatic Hydrocarbons and Related Chemicals and is the direct responsibility ofSubcommittee D16.02 on Oxygenated Aromatics.Current edition approved Aug. 1, 2013. Published October 2013. DOI: 10.1520/D7884-13.2For referenced ASTM standards, visit the AS
13、TM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.3Available from American National Standards Institute (ANSI), 25 W. 43rd St.,4th Floor, New York, NY 1003
14、6, http:/www.ansi.org.4Available from U.S. Government Printing Office Superintendent of Documents,732 N. Capitol St., NW, Mail Stop: SDE, Washington, DC 20401, http:/www.access.gpo.gov.Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States1b
15、etween 0.1 and 2.0 mL/min, with a pressure between 0 and 40MPa and a pulsation of less than 1 % full scale deflection underthe test conditions described in Table 1. The S/N (signal tonoise) ratio should be 3:1 or greater for 2 mg/kg 4-CBAand 10mg/kg p-TOL.5.2 Sample Injection Systemcapable of inject
16、ing 1 to 25L, using either partial or full loop mode, with a repeatabilityof 61%.5.3 DetectorVariable Wavelength Ultraviolet PhotometricDetector (VWD), Multi-wavelength Detector, or PhotometricDiode Array Detector (PDA)capable of operating at 240 and254 nm.5.4 Column Ovenany suitable HPLC column ove
17、n (blockheating or air circulating) capable of maintaining a constanttemperature of 61C within the range of 20 to 70C.5.5 Chromatography Data System.5.6 HPLC Columns:5.6.1 A stainless steel HPLC column packed with an octa-decylsilane (C18) chemically bonded silica stationary phase issuitable. See Ta
18、ble 1 for recommended operating conditions.5.6.2 A C18 column with different dimensions (innerdiameter, length, particle size, etc.) that provides adequateresolution to quantitate 4-CBAand p-TOLin a PTAsample canalso be used.5.7 Analytical Balancereadable to 60.0001 g.5.8 Sample FilterA disposable s
19、yringe filter made ofcellulose acetate, with a pore size between 0.22 and 0.45 m,and is chemically inert to aqueous solutions, is recommendedfor the removal of particulate matter from the sample solution.6. Reagents and Materials6.1 Purity of ReagentsUnless otherwise indicated, it isintended that al
20、l reagents shall conform to the reagent gradespecification for analytical reagents of the American ChemicalSociety, where such specifications are available.5Other gradesmay be used, provided it is first ascertained that the reagent isof sufficiently high purity to permit its use without lesseningthe
21、 performance or accuracy of the determination. Reagentchemicals shall be used for all tests.NOTE 1Calibration and detection limits of this test method can bebiased by the purity of the reagents.6.2 Ammonium Hydroxide25 to 28 %.6.3 Phosphoric AcidHPLC grade.6.4 AcetonitrileHPLC grade. (WarningAcetoni
22、trile isflammable and hazardous in case of skin or eye contact,ingestion, or inhalation.)6.5 WaterHPLC grade.6.6 Ammonium Hydroxide Solutionammonium hydroxidemixed with water as 1:1 (V:V).6.7 PTA Standard for CalibrationA certified PTA calibra-tion standard with known amounts of 4-CBA and p-TOL isre
23、quired. If it is not commercially available, please refer toAnnex A1 for determining the concentrations of 4-CBA andp-TOL in a PTA sample. The calibrated PTA sample can beserved as a PTA calibration standard.6.8 Mobile Phase:6.8.1 0.06 % H3PO4Solution:Acetonitrile = 82:18Pipette 0.6 mL H3PO4into a 1
24、000 mL volumetric flask with900 mL of water and make up to the mark with water to give0.06 % H3PO4solution. Mix 820 mL of H3PO4solution and180 mL of acetonitrile. Methanol could be used as an alterna-tive to acetonitrile in the mobile phase.NOTE 2It is recommended to degas and filter the mobile phas
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMD788420135625STANDARDTESTMETHODFORDETERMINATIONOF4CARBOXYBENZALDEHYDEANDPTOLUICACIDINPURIFIEDTEREPHTHALICACIDBYREVERSEPHASEHIGHPERFORMANCELIQUIDCHROMAPDF

链接地址:http://www.mydoc123.com/p-526476.html