ASTM D7871-2013 9375 Standard Test Method for Analysis of Cyclohexane by Gas Chromatography (Effective Carbon Number)《采用气相色谱法分析环己烷的标准试验方法(有效碳数)》.pdf
《ASTM D7871-2013 9375 Standard Test Method for Analysis of Cyclohexane by Gas Chromatography (Effective Carbon Number)《采用气相色谱法分析环己烷的标准试验方法(有效碳数)》.pdf》由会员分享,可在线阅读,更多相关《ASTM D7871-2013 9375 Standard Test Method for Analysis of Cyclohexane by Gas Chromatography (Effective Carbon Number)《采用气相色谱法分析环己烷的标准试验方法(有效碳数)》.pdf(6页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: D7871 13Standard Test Method forAnalysis of Cyclohexane by Gas Chromatography (EffectiveCarbon Number)1This standard is issued under the fixed designation D7871; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the year
2、 of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope1.1 This test method covers the determination of the purityof cyclohexane by gas chromatography.1.2 This test method h
3、as been found applicable to themeasurement of impurities such as those found in Table 1,which are impurities that may be found in cyclohexane. Theimpurities can be analyzed over a range of 1 to 400 mg/kg bythis method, but may be applicable to a wider range.1.3 The limit of detection is 1 mg/kg.1.4
4、In determining the conformance of the test results usingthis test method to applicable specifications, results shall berounded off in accordance with the rounding-off method ofPractice E29.1.5 The values stated in SI units are to be regarded asstandard. No other units of measurement are included in
5、thisstandard.1.6 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use. F
6、or specific hazardsstatements, see Section 8.2. Referenced Documents2.1 ASTM Standards:2D3437 Practice for Sampling and Handling Liquid CyclicProductsD4790 Terminology of Aromatic Hydrocarbons and RelatedChemicalsD6809 Guide for Quality Control and Quality AssuranceProcedures for Aromatic Hydrocarbo
7、ns and Related Ma-terialsE29 Practice for Using Significant Digits in Test Data toDetermine Conformance with SpecificationsE355 Practice for Gas Chromatography Terms and Relation-shipsE691 Practice for Conducting an Interlaboratory Study toDetermine the Precision of a Test MethodE1510 Practice for I
8、nstalling Fused Silica Open TubularCapillary Columns in Gas Chromatographs2.2 Other Standards:3OSHA Regualtions, 29 CFR paragraphs 1910.1000 and1910.12003. Terminology3.1 See Terminology D4790 for definitions of terms used inthis test method.4. Summary of Test Method4.1 The specimen to be analyzed i
9、s injected into a gaschromatograph equipped with a flame ionization detector (FID)and a capillary column. The peak area of each component ismeasured and adjusted using effective carbon number (ECN)4response factors. The concentration of each component iscalculated based on its relative percentages o
10、f total adjustedpeak area and normalized to 100.0000 %.5. Significance and Use5.1 This test method is suitable for setting specifications onthe materials referenced in Table 1 and for use as an internalquality control tool where cyclohexane is produced or is usedin a manufacturing process. It may al
11、so be used in developmentor research work involving cyclohexane.5.2 This test method is useful in determining the purity ofcyclohexane with normal impurities present. If extremely highboiling or unusual impurities are present in the cyclohexane,this test method would not necessarily detect them and
12、thepurity calculation would be erroneous.1This test method is under the jurisdiction of ASTM Committee D16 onAromatic Hydrocarbons and Related Chemicals and is the direct responsibility ofSubcommittee D16.01 on Benzene, Toluene, Xylenes, Cyclohexane and TheirDerivatives.Current edition approved June
13、 1, 2013. Published July 2013. DOI: 10.1520/D7871-13.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.3Availab
14、le from U.S. Government Printing Office Superintendent of Documents,732 N. Capitol St., NW, Mail Stop: SDE, Washington, DC 20401, http:/www.access.gpo.gov.4Scanlon, J. T. and Willis, D. E., “Calculation of Flame Ionization DetectorRelative Response Factors Using the Effective Carbon Concept,” Journa
15、l ofChromatographic Science, Vol. 23, August 1985, ppl. 333-339.Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States16. Apparatus6.1 Gas ChromatographAny instrument having a flameionization detector that can be operated at the conditions g
16、ivenin Table 2. The system should have sufficient sensitivity toobtain a minimum peak height response for 1 mg/kg benzeneof twice the height of the signal background noise.6.2 ColumnsThe choice of column is based on resolutionrequirements. Any column may be used that is capable ofresolving all signi
17、ficant impurities from cyclohexane. Thecolumn described in Table 2 has been used successfully.6.3 RecorderElectronic integration is required.6.4 InjectorThe specimen must be precisely and repeat-ably injected into the gas chromatograph.An automatic sampleinjection device is highly recommended. Manua
18、l injection maybe employed if the precision stated in Tables 48 can bereliably and consistently satisfied.7. Reagents and Materials7.1 Purity of ReagentsReagent grade chemicals shall beused in all tests. Unless otherwise indicated, it is intended thatall reagents shall conform to the specifications
19、of the Commit-tee on Analytical Reagents of the American Chemical Society,where such specifications are available.5Other grades may beused, provided it is first ascertained that the reagent is ofsufficiently high purity to permit its use without lessening theaccuracy of the determination.8. Hazards8
20、.1 Consult current OSHA regulations, suppliers MaterialSafety Data Sheets, and local regulations for all materials listedin this test method.9. Sampling and Handling9.1 Sample the material in accordance with Practice D3437.10. Preparation of Apparatus10.1 Follow manufacturers instructions for mounti
21、ng andconditioning the column into the chromatograph and adjustingthe instrument to the conditions described in Table 2 allowingsufficient time for the equipment to reach equilibrium. SeePractices E1510 and E355 for additional information on gaschromatography practices and terminology.11. Calibratio
22、n and Standardization11.1 Prior to implementation of the ECN method, a labora-tory should demonstrate that acceptable precision and bias canbe obtained using a synthetic mixture of known composition(calibration check sample). (Fig. 1)12. Procedure12.1 Bring the sample to room temperature.12.2 Check
23、the chromatography performance to make surethat the column is properly resolving peaks.5Reagent Chemicals, American Chemical Society Specifications, AmericanChemical Society, Washington, DC. For suggestions on the testing of reagents notlisted by the American Chemical Society, see Analar Standards f
24、or LaboratoryChemicals, BDH Ltd., Poole, Dorset, U.K., and the United States Pharmacopeiaand National Formulary, U.S. Pharmacopeial Convention, Inc. (USPC), Rockville,MD.TABLE 1 Impurities Known or Suggested to be Present inCommercial CyclohexaneC4(1) n-butane(2) isobuteneC5(3) n-pentane(4) isopenta
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMD787120139375STANDARDTESTMETHODFORANALYSISOFCYCLOHEXANEBYGASCHROMATOGRAPHYEFFECTIVECARBONNUMBER 采用

链接地址:http://www.mydoc123.com/p-526456.html