ASTM D7725-2017 red 0000 Standard Test Method for the Continuous Measurement of Turbidity Above 1 Turbidity Unit (TU)《连续测量1浊度单位以上浊度的标准试验方法(TU)》.pdf
《ASTM D7725-2017 red 0000 Standard Test Method for the Continuous Measurement of Turbidity Above 1 Turbidity Unit (TU)《连续测量1浊度单位以上浊度的标准试验方法(TU)》.pdf》由会员分享,可在线阅读,更多相关《ASTM D7725-2017 red 0000 Standard Test Method for the Continuous Measurement of Turbidity Above 1 Turbidity Unit (TU)《连续测量1浊度单位以上浊度的标准试验方法(TU)》.pdf(31页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: D7725 12D7725 17Standard Test Method for theContinuous Measurement of Turbidity Above 1 TurbidityUnit (TU)1This standard is issued under the fixed designation D7725; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the
2、year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope1.1 This test method covers the onlineon-line and inlinein-line determination of high-level turbidity in water tha
3、t is greater than1.0 turbidity units (TU) in municipal, industrial and environmental usage.1.2 In principle, there are three basic applications for on-line measurement set ups. This first is the slipstream (bypass) sampletechnique. For the slipstream sample technique a portion of sample is transport
4、ed out of the process and through the measurementapparatus. It is then either transported back to the process or to waste. The second is the in-line measurement where the sensoris brought directly into the process (see Fig. 8). The third basic method is for in-situ monitoring of sample waters. This
5、principleis based on the insertion of a sensor into the sample itself as the sample is being processed. The in-situ use in this test method isintended for the monitoring of water during any step within a processing train, including immediately before or after the processitself.1.3 This test method i
6、s applicable to the measurement of turbidities greater than 1.0 turbidity unit (TU). TU. The absolute rangeis dictated by the technology that is employed.1.4 The upper end of the measurement range is left undefined because different technologies described in this test method cancover very different
7、ranges of turbidity.1.5 Many of the turbidity units and instrument designs covered in this test method are numerically equivalent in calibrationwhen a common calibration standard is applied across those designs listed in Table 1. Measurement of a common calibrationstandard of a defined value will al
8、so produce equivalent results across these technologies. This test method prescribes theassignment of a determined turbidity values to the technology used to determine those values. Numerical equivalence to turbiditystandards is observed between different technologies but is not expected across a co
9、mmon sample. Improved traceability beyondthe scope of this test method may be practiced and would include the listing of the make and model number of the instrument usedto determine the turbidity values.1.5.1 In this test method, calibration standards are often defined in NTU values, but the other a
10、ssigned turbidity units, such asthose in Table 1 are equivalent. For example, a 1 NTU formazin standard is also a 1 FNU, a 1 FAU, a 1 BU, and so forth.1.6 This standard test method does not purport to cover all available technologies for high-level turbidity measurement.1.7 This test method was test
11、ed on different waters, and with standards that will serve as surrogates to samples. It is theusersusers responsibility to ensure the validity of this test method for waters of untested matrices.1.8 Those samples with the highest particle densities typically prove to be the most difficult to measure
12、. In these cases, theprocess monitoring method can be considered with adequate measurement protocols installed.1.9 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.1.10 This standard does not purport to address all of the safet
13、y concerns, if any, associated with its use. It is the responsibilityof the user of this standard to establish appropriate safety safety, health, and healthenvironmental practices and determine theapplicability of regulatory limitations prior to use. Refer to the MSDSs for all chemicals used in this
14、 procedure.1.11 This international standard was developed in accordance with internationally recognized principles on standardizationestablished in the Decision on Principles for the Development of International Standards, Guides and Recommendations issuedby the World Trade Organization Technical Ba
15、rriers to Trade (TBT) Committee.1 This test method is under the jurisdiction of ASTM Committee D19 on Water and is the direct responsibility of Subcommittee D19.03 on Sampling Water andWater-Formed Deposits, Analysis of Water for Power Generation and Process Use, On-Line Water Analysis, and Surveill
16、ance of Water.Current edition approved Jan. 1, 2012Dec. 15, 2017. Published June 2012February 2018. Originally approved in 2012. Last previous edition approved in 2012 as D7725 12. DOI: 10.1520/D7725-12.10.1520/D7725-17.This document is not an ASTM standard and is intended only to provide the user o
17、f an ASTM standard an indication of what changes have been made to the previous version. Becauseit may not be technically possible to adequately depict all changes accurately, ASTM recommends that users consult prior editions as appropriate. In all cases only the current versionof the standard as pu
18、blished by ASTM is to be considered the official document.Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States1TABLE 1 Technologies for Measuring Turbidity Greater Than 1 TU that can be used for In-Line or On-Line ApplicationsDesign and Re
19、portingUnit Prominent Application Key Design Features Typical Instrument Range Suggested ApplicationNephelometric non- ratio(NTU)White light turbidimetersComply with EPA 180.1 for lowlevel turbidity monitoring.Detector centered at 90 degreesrelative to the incident lightbeam. Uses a white light spec
20、tralsource.0.012 to 40 NTU Regulatory reporting ofcleanwaterRatio White Light turbidimeters(NTRU)Complies with ISWTRregulations and Standard Method2130B. Can be used for bothlow and high level measurement.Used a white light spectralsource. Primary detectorcentered at 90. Other detectorslocated at ot
21、her angles. Aninstrument algorithm uses acombination of detector readingsto generate the turbidity reading.0.012 - 10,000 NTRU Regulatory Reporting ofcleanwaterFormazin Nephelometric,near-IR turbidimeters, non-ratiometric (FNU)Complies with ISO 7027. Thewavelengthis less susceptible tocolor interfer
22、ences. Applicablefor samples with color and goodfor low level monitoring.Detector centered at 90 degreesrelative to the incident lightbeam. Uses a near-IR (780-900nm) monochromatic light source.0.012 - 1,000 FNU 0 - 40 FNU ISO 7027Regulatory reportingFormazin Nephelometricnear-IRturbidimeters, ratio
23、metric(FNRU)Complies with ISO 7027.Applicable for samples with highlevels of color and for monitoringto high turbidity levels.Uses a near-IR monochromaticlight source (780-900 nm).Primary detector centered at 90.Other detectors located at otherangles. An instrument algorithmuses a combination of det
24、ectorreadings to generate the turbidityreading.0.012 - 1,000 FNU 0- 40 FNRU ISO 7027Regulatory reportingSurface Scatter Turbidimeters(SSU)Turbidity is determined throughlight scatter from a definedvolume beneath the surface of asample. Applicable for reportingfor USEPA compliancemonitoring.Detector
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMD77252017RED0000STANDARDTESTMETHODFORTHECONTINUOUSMEASUREMENTOFTURBIDITYABOVE1TURBIDITYUNITTU 连续

链接地址:http://www.mydoc123.com/p-526193.html