1、Designation: D7724 11 (Reapproved 2016)D7724 18Standard Test Method forCarbon BlackNon-Dispersible Matter by MechanicalFlushing (NDM)1This standard is issued under the fixed designation D7724; the number immediately following the designation indicates the year oforiginal adoption or, in the case of
2、revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope1.1 This test method covers the determination of non-dispersible matter after mechanical water flush
3、ing of regular untreatedcarbon blacks. It may not be applicable to oil-treated carbon blacks because the oil would prevent proper wetting of the black bywater.1.2 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.1.3 This standa
4、rd does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibilityof the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatorylimitations prior to use.1.3 This standard does not purpo
5、rt to address all of the safety concerns, if any, associated with its use. It is the responsibilityof the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability ofregulatory limitations prior to use.1.4 This international standard w
6、as developed in accordance with internationally recognized principles on standardizationestablished in the Decision on Principles for the Development of International Standards, Guides and Recommendations issuedby the World Trade Organization Technical Barriers to Trade (TBT) Committee.2. Referenced
7、 Documents2.1 ASTM Standards:2D1799 Practice for Carbon BlackSampling Packaged ShipmentsD1900 Practice for Carbon BlackSampling Bulk ShipmentsD4483 Practice for Evaluating Precision for Test Method Standards in the Rubber and Carbon Black Manufacturing IndustriesE11 Specification for Woven Wire Test
8、 Sieve Cloth and Test Sieves3. Summary of Test Method3.1 A sample of carbon black is mechanically flushed with water through a wire-mesh screen of a specified size until all thatremains is a non-dispersible matter of carbon black. The non-dispersible matter is dried, weighed, and the amount of resid
9、ue isexpressed as mg/kg (ppm) of the original sample.4. Significance and Use4.1 The quantity of non-dispersible matter of carbon black is important in some molded or extruded products as it may relateto the surface appearance of those products. The maximum amount of non dispersible matter and the mi
10、nimum size of the particlesto be analyzed in each application is normally determined and agreed to between the user and the producer.1 This test method is under the jurisdiction of ASTM Committee D24 on Carbon Black and is the direct responsibility of Subcommittee D24.31 on Non-Carbon BlackComponent
11、s of Carbon Black.Current edition approved June 1, 2016June 1, 2018. Published July 2016July 2018. Originally approved in 2011. Last previous edition approved in 20112016 asD7724 11.D7724 11 (2016). DOI: 10.1520/D7724-11R16.10.1520/D7724-18.2 For referencedASTM standards, visit theASTM website, www.
12、astm.org, or contactASTM Customer Service at serviceastm.org. For Annual Book of ASTM Standardsvolume information, refer to the standards Document Summary page on the ASTM website.This document is not an ASTM standard and is intended only to provide the user of an ASTM standard an indication of what
13、 changes have been made to the previous version. Becauseit may not be technically possible to adequately depict all changes accurately, ASTM recommends that users consult prior editions as appropriate. In all cases only the current versionof the standard as published by ASTM is to be considered the
14、official document.Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States15. Apparatus5.1 Sieve Apparatus, as shown in Fig. 1.35.2 Balance, with a sensitivity of 0.01 g.5.3 Analytical Balance, with a sensitivity of 0.1 mg.5.4 Oven, gravity-co
15、nvection type, capable of temperature regulation within 61C at 125C and temperature uniformity within65C.5.5 Sieves, diameter 100 mm, of either phosphor bronze or stainless steel.3 The sieve shall be in accordance with SpecificationE11. The sieve size to be used shall be agreed upon between the purc
16、haser and the carbon black manufacture.5.6 Weighing Dishes.6. Precautions6.1 Install the apparatus as described in the manufacturers instructions and keep it clean at all times to prevent contamination.6.2 Examine the sieves each time they are used to make sure that no cracks or holes have developed
17、.7. Sampling7.1 Samples shall be taken in accordance with Practice D1799 or Practice D1900.8. Procedure8.1 Prior to each test series adjust the water pressure to 400 6 20 kPa in accordance with the manufacturers instructions. Makesure that only the spraying nozzle is operating when pressure is adjus
18、ted.NOTE 1The pressure will drop when the cleaning nozzles are operating in addition to the spraying nozzle.8.2 Attach the sieve to the apparatus in accordance with the manufacturers instructions and push the “flush” button for at least5 s. The water is flushed through the nozzles as long as the “fl
19、ush” button is pushed.8.3 After releasing the “flush” button disassemble the sieve and examine the sieve for particles. If no particles are observedreattach the sieve.8.4 Weigh 500 6 5 g of the sample into a container and transfer the sample quantitatively into the cylinder of the test apparatus.Not
20、e the correct weight for the calculation of the non dispersible matter.3 The sole source of supply of the apparatus known to the committee at this time is Krahnen IQS, GmbH, Paffrather Str. 1315, D-51069 Koeln, Germany. If you are awareof alternative suppliers, please provide this information toASTM
21、 International Headquarters.Your comments will receive careful consideration at a meeting of the responsibletechnical committee,1 which you may attend.FIG. 1 Schematic Diagram of NDA Test EquipmentD7724 1828.5 Press the “start” button and close the lid slowly while the spraying nozzle is rotating wi
22、thout any water flushing. Theflushing process will start automatically.8.6 Based on a predefined program the sample will be flushed through the sieve by the water spray nozzles. For details referto Fig. 1.8.7 Avacuum is applied periodically to keep the non dispersible particles immobilized on the si
23、eve in order to wash dispersibleproduct from the non dispersible matter. The vacuum application is also part of the automated process.8.8 The end of the test is indicated by a vacuum application without any water flowing. After that the measurement stops.8.9 Disassemble the sieve and dry in an oven
24、at a temperature of 125C for 1 h.8.10 Quantitatively transfer the non dispersible matter to a tared weighing dish and weigh to the nearest 0.1 mg using theanalytical balance.9. Calculation9.1 Calculate the non-dispersible matter to the nearest mg/kg (ppm) as follows:R 5W/S! 3106 (1)where:R = Non-dis
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMD77242018RED5625STANDARDTESTMETHODFORCARBONBLACKX2014NONDISPERSIBLEMATTERBYMECHANICALFLUSHINGNDMPDF

链接地址:http://www.mydoc123.com/p-526191.html