ASTM D7482-2014 red 9874 Standard Practice for Sampling Storage and Handling of Hydrocarbons for Mercury Analysis《汞分析用碳氢化合物的取样 存储以及处理的标准实施规程》.pdf
《ASTM D7482-2014 red 9874 Standard Practice for Sampling Storage and Handling of Hydrocarbons for Mercury Analysis《汞分析用碳氢化合物的取样 存储以及处理的标准实施规程》.pdf》由会员分享,可在线阅读,更多相关《ASTM D7482-2014 red 9874 Standard Practice for Sampling Storage and Handling of Hydrocarbons for Mercury Analysis《汞分析用碳氢化合物的取样 存储以及处理的标准实施规程》.pdf(5页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: D7482 08D7482 14Standard Practice forSampling, Storage, and Handling of Hydrocarbons forMercury Analysis1This standard is issued under the fixed designation D7482; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the ye
2、ar of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope Scope*1.1 This practice covers the types of and preparation of containers found most suitable for the handling of h
3、ydrocarbon samplesfor the determination of total mercury.1.2 This practice was developed for sampling streams where the mercury speciation is predominantly Hg(0) present as a mixtureof dissolved Hg(0) atoms, adsorbed Hg(0) on particulates (for example, carbonaceous or mineral fines and Fe2O3) and su
4、spendeddroplets of metallic mercury.1.3 The presence of suspended droplets of metallic mercury (often called “colloidal” mercury, since the droplet size can be verysmall) can make obtaining a representative sample very difficult for a variety of reasons (for example, non-isokinetic sampling ofthe li
5、quid can result in over- or under-collection of suspended droplets and collection of mercury that has accumulated in denselarger drops and pools on the bottom of piping and in sample taps). Pay strict attention to the detailed procedure (Section 7) toensure representative samples are collected.1.4 W
6、hen representative test portions are collected and analyzed in accordance with acceptable procedures, the total mercuryis representative of concentrations in the sample.1.5 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.1.6 W
7、arningMercury has been designated by EPA and many state agencies as a hazardous material that can cause centralnervous system, kidney, and liver damage. Mercury, or its vapor, may be hazardous to health and corrosive to materials. Cautionshould be taken when handling mercury and mercury-containing p
8、roducts. See the applicable product Material Safety Data Sheet(MSDS) for details and EPAs website (http:/www.epa.gov/mercury/faq.htm) for additional information. Users should be awarethat selling mercury or mercury-containing products, or both, in your state may be prohibited by state law.1.7 This s
9、tandard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibilityof the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatorylimitations prior to use.2. Referenced Documents2.1
10、ASTM Standards:2D4175 Terminology Relating to Petroleum, Petroleum Products, and Lubricants2.2 EPA Standard:3EPA Method 1669 Sampling Ambient Water for Trace Metals at EPA Water Quality Criteria Levels; July 1996; USEnvironmental Protection Agency3. Terminology3.1 DefinitionsFor definitions of terms
11、 used in this standard, refer to Terminology D4175.3.2 Abbreviations:3.2.1 VOAVolatile Organic Analysis1 This practice is under the jurisdiction of ASTM Committee D02 on Petroleum Products Products, Liquid Fuels, and Lubricants and is the direct responsibility ofSubcommittee D02.03 on Elemental Anal
12、ysis.Current edition approved Oct. 15, 2008Oct. 1, 2014. Published November 2008October 2014. Originally approved in 2008. Last previous edition approved in 2008 asD7482 08. DOI: 10.1520/D7482-08.10.1520/D7482-14.2 For referencedASTM standards, visit theASTM website, www.astm.org, or contactASTM Cus
13、tomer Service at serviceastm.org. For Annual Book of ASTM Standardsvolume information, refer to the standards Document Summary page on the ASTM website.3 Available from United States Environmental Protection Agency (EPA), Ariel Rios Bldg., 1200 Pennsylvania Ave., NW, Washington, DC 20460 (www.epa.go
14、v).This document is not an ASTM standard and is intended only to provide the user of an ASTM standard an indication of what changes have been made to the previous version. Becauseit may not be technically possible to adequately depict all changes accurately, ASTM recommends that users consult prior
15、editions as appropriate. In all cases only the current versionof the standard as published by ASTM is to be considered the official document.*A Summary of Changes section appears at the end of this standardCopyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-
16、2959. United States14. Summary of Practice4.1 This practice describes the sampling, storage, transport, and handling of hydrocarbon samples used for determining mercury,and the precautions that need to be taken to prevent sample contamination and loss of analyte.5. Significance and Use5.1 This pract
17、ice is intended for use in sampling liquid hydrocarbons including crude oils, condensates, refinery processintermediates, and refined products. Generally these samples are expected to contain mercury from the parts per billion (10-9 mass)to parts per million (10-6 mass) range.5.2 This practice is no
18、t intended for use when sampling aqueous systems where the concentrations of mercury are often in theparts per trillion (10-12 mass) range. These samples are often better addressed by using the rigorously clean techniques from theEPA Method 1669 “clean hands, dirty hands” sampling procedures.5.3 Thi
19、s practice is not intended for use for liquefied samples, for which special containers may be required for pressurizedsamples.5.4 This practice is only suitable for stabilized samples which remain 100 % liquid at ambient conditions. For samples that ondepressurization lose some of the light hydrocar
20、bon ends it is important to note that elemental mercury may be lost duringsampling. Sampling modules which inject unstabilized liquid hydrocarbons close to process conditions directly to the mercuryanalyzer can be used to overcome this issue.5.5 In some refined streams and in tank samples free water
21、 may be present. Process streams that are water saturated maycondense water as the sample cools from process temperature to ambient temperature. Ionic mercury species are water soluble andthese water droplets may contain mercury or adsorb mercury over time.5.6 The presence of mercury during crude oi
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMD74822014RED9874STANDARDPRACTICEFORSAMPLINGSTORAGEANDHANDLINGOFHYDROCARBONSFORMERCURYANALYSIS 分析

链接地址:http://www.mydoc123.com/p-525614.html