1、Designation: D7385 13Standard Guide forEstimating Carbon Saturation by Temperature Rise uponImmersion1This standard is issued under the fixed designation D7385; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the year of last revis
2、ion. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope1.1 This guide covers the measurement of the temperaturerise resulting from the heat of immersion when a known massof a specified or
3、ganic liquid is added to a sample of activatedcarbon. If the carbon has been in use as an adsorbent and maytherefore be partially or fully exhausted, its degree of satura-tion may be estimated by comparing its temperature rise withthat of an unused sample of the same activated carbon.1.2 The values
4、stated in SI units are to be regarded asstandard. No other units of measurement are included in thisstandard.1.3 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety
5、 and health practices and determine the applica-bility of regulatory limitations prior to use.2. Referenced Documents2.1 ASTM Standards:2D2652 Terminology Relating to Activated CarbonD2854 Test Method for Apparent Density of ActivatedCarbonD2867 Test Methods for Moisture in Activated CarbonE300 Prac
6、tice for Sampling Industrial Chemicals3. Terminology3.1 Terms related to this guide are defined in TerminologyD2652.4. Summary of Guide4.1 A measured volume of activated carbon is added to aknown volume of a selected organic liquid in a containerprovided with means to measure the liquid temperature.
7、 Theapparatus is sealed after the addition of the carbon and themaximum rise in temperature is recorded. The degree ofsaturation of a used carbon is estimated by comparing itstemperature rise with that of the original unused activatedcarbon of equivalent moisture content, measured under thesame cond
8、itions. If no such reference sample is available, acommercial unused activated carbon of the same physical typefrom a reputable manufacturer may be substituted; suchsubstitution should be noted in the report.5. Significance and Use5.1 It is often useful to estimate the degree of saturation,and hence
9、 the expected remaining service life, of activatedcarbon that has been in use for some time. This guide isapplicable when such information must be obtained fairlyrapidly under field conditions without access to optimal ana-lytical instruments.36. Apparatus and Materials6.1 ApparatusThe apparatus sho
10、uld consist of a containersuch as a small bottle or flask to accommodate the carbon, theorganic liquid, and a thermometer or thermocouple with arange to allow for a temperature rise of up to about 30 C,graduated in intervals of 0.5 C, with facility to interpolate to60.1 C. A liquid-in-glass thermome
11、ter should not usemercury, because of the greater risk of breakage under fieldconditions. The container should be provided with a rubberstopper or other suitable closure to seal the contents after thecarbon has been added to the organic liquid. Appropriatecontainers include an Erlenmeyer or Florence
12、 flask of about125 to 250 mL capacity or a similar-sized narrow-neckedbottle.6.2 MaterialsMany organic liquids that are insoluble inwater but readily soluble in other adsorbates that may alreadybe on the carbon are potentially useful. Those that have beentried include mineral oil, hexane, cyclohexan
13、e, and kerosene.Mineral oil is essentially harmless and not readily flammable,so its use does not require warnings for personnel untrained inhandling laboratory chemicals, but it has the disadvantage of1This guide is under the jurisdiction of ASTM Committee D28 on ActivatedCarbonand is the direct re
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMD738520135000STANDARDGUIDEFORESTIMATINGCARBONSATURATIONBYTEMPERATURERISEUPONIMMERSION 采用 浸入 温升法 评估

链接地址:http://www.mydoc123.com/p-525329.html