ASTM D7279-2014 9626 Standard Test Method for Kinematic Viscosity of Transparent and Opaque Liquids by Automated Houillon Viscometer《使用自动Houillon粘度计测定透明和不透明液体运动粘度的标准试验方法》.pdf
《ASTM D7279-2014 9626 Standard Test Method for Kinematic Viscosity of Transparent and Opaque Liquids by Automated Houillon Viscometer《使用自动Houillon粘度计测定透明和不透明液体运动粘度的标准试验方法》.pdf》由会员分享,可在线阅读,更多相关《ASTM D7279-2014 9626 Standard Test Method for Kinematic Viscosity of Transparent and Opaque Liquids by Automated Houillon Viscometer《使用自动Houillon粘度计测定透明和不透明液体运动粘度的标准试验方法》.pdf(7页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: D7279 14Standard Test Method forKinematic Viscosity of Transparent and Opaque Liquids byAutomated Houillon Viscometer1This standard is issued under the fixed designation D7279; the number immediately following the designation indicates the year oforiginal adoption or, in the case of rev
2、ision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope*1.1 This test method covers the measurement of the kine-matic viscosity of transparent and opaque liqu
3、ids; such as baseoils, formulated oils, diesel oil, biodiesel, biodiesel blends, andused lubricating oils using a Houillon viscometer in automatedmode.1.2 The range of kinematic viscosity capable of beingmeasured by this test method is from 2 mm2/s to 1500 mm2/s(see Fig. 1). The range is dependent o
4、n the tube constantutilized. The temperature range that the apparatus is capable ofachieving is between 20 C and 150 C, inclusive. However,the precision has only been determined for the viscosity range;2mm2/s to 478 mm2/s at 40 C for base oils, formulated oils,diesel oil, biodiesel, and biodiesel bl
5、ends; 3 mm2/s to106 mm2/s at 100 C for base oils and formulated oils;25 mm2/s to 150 mm2/s at 40 C and 5 mm2/s to 16 mm2/s at100 C for used lubricating oils. As indicated for the materialslisted in the precision section.1.3 The values stated in SI units are to be regarded asstandard. No other units
6、of measurement are included in thisstandard.1.4 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulat
7、ory limitations prior to use. For specificwarning statements, see Section 6.2. Referenced Documents2.1 ASTM Standards:2D445 Test Method for Kinematic Viscosity of Transparentand Opaque Liquids (and Calculation of Dynamic Viscos-ity)D2162 Practice for Basic Calibration of Master Viscometersand Viscos
8、ity Oil StandardsD4057 Practice for Manual Sampling of Petroleum andPetroleum ProductsD4177 Practice for Automatic Sampling of Petroleum andPetroleum ProductsD6299 Practice for Applying Statistical Quality Assuranceand Control Charting Techniques to Evaluate AnalyticalMeasurement System PerformanceD
9、6708 Practice for Statistical Assessment and Improvementof Expected Agreement Between Two Test Methods thatPurport to Measure the Same Property of a MaterialD6792 Practice for Quality System in Petroleum Productsand Lubricants Testing LaboratoriesD7042 Test Method for Dynamic Viscosity and Density o
10、fLiquids by Stabinger Viscometer (and the Calculation ofKinematic Viscosity)2.2 ISO Standards:ISO 5725 Accuracy (Trueness and Precision) of Measure-ment Methods and Results3ISO/EC 17025 General Requirements for the Competence ofTesting and Calibration Laboratories32.3 NIST Standard:NIST Technical No
11、te 1297 Guideline for Evaluating andExpressing the Uncertainty of NIST Measurement Re-sults43. Summary of Test Method3.1 The kinematic viscosity is determined by measuring thetime taken for a sample to fill a calibrated volume at a giventemperature. The specimen is introduced into the apparatus andt
12、hen flows into the viscometer tube which is equipped with twodetection cells. The specimen reaches the test temperature ofthe viscometer bath and when the leading edge of the specimenpasses in front of the first detection cell, the automatedinstrument starts the timing sequence. When the leading edg
13、e1This test method is under the jurisdiction of ASTM Committee D02 onPetroleum Products, Liquid Fuels, and Lubricants and is the direct responsibility ofSubcommittee D02.07 on Flow Properties.Current edition approved May 1, 2014. Published July 2014. Originally approvedin 2006. Last previous edition
14、 approved in 2008 as D7279 08. DOI: 10.1520/D7279-14.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.3Availab
15、le from American National Standards Institute (ANSI), 25 W. 43rd St.,4th Floor, New York, NY 10036, http:/www.ansi.org.4Available from National Institute of Standards and Technology (NIST), 100Bureau Dr., Stop 1070, Gaithersburg, MD 20899-1070, http:/www.nist.gov.*A Summary of Changes section appear
16、s at the end of this standardCopyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States1of the specimen passes in front of the second detection cell, theinstrument stops timing the flow. The time interval thusmeasured allows the calculation of t
17、he kinematic viscosityusing a viscometer tube constant determined earlier by calibra-tion with certified viscosity reference standards.3.2 The kinematic viscosity is calculated using the formula: 5 C 3t (1)where: = the kinematic viscosity in mm2/s,C = the viscometer tube constant in mm2/s, andt = th
18、e flow time in s measured during the test.4. Significance and Use4.1 Many petroleum products and some non-petroleumproducts are used as lubricants in the equipment, and thecorrect operation of the equipment depends upon the appropri-ate viscosity of the lubricant being used. Additionally, theviscosi
19、ty of many petroleum fuels is important for the estima-tion of optimum storage, handling, and operational conditions.Thus, the accurate determination of viscosity is essential tomany product specifications.4.2 The viscosity of used oils is a commonly determinedparameter in the oil industry to assess
20、 the effect of engine wearon the lube oils used, as well as the degradation of the engineparts during operation.4.3 The Houillon viscometer tube method offers automateddetermination of kinematic viscosity. Typically a sample vol-ume of less than 1 mL is required for the analysis.5. Apparatus5.1 Auto
21、mated ViscometerThe system shall consist of thefollowing components:5.1.1 Viscometer Bath:5.1.1.1 Bath, to ensure optimal thermal equilibration of thesystem, the bath is filled with mineral or silicone oil andequipped with a stirring device.5.1.2 Temperature Regulation System, to control the bathtem
22、perature to within 0.02 C.5.1.3 Houillon Viscometer Tubes, made of glass with acalibrated volume which varies depending on the tube size (seeFig. 2). This technique allows the viscosity to be measuredover a wide range of values (see Fig. 1).5.1.4 Cleaning/Vacuum System, consisting of one or moresolv
23、ent reservoirs to transport the solvent(s) to the viscometertubes, dry the viscometer tubes after the flushing cycle, toremove the sample, and for drainage of waste products.5.1.5 Automated Viscometer Control SystemSuitable elec-tronic processor capable of operating the apparatus, controllingthe ope
24、ration of the timers, regulating the bath temperature,cleaning the viscometer tubes, and recording and reporting theresults.5.1.6 PC-compatible Computer System, may be used fordata acquisition, as per manufacturers instructions.5.1.7 Temperature Measuring DevicesUse either cali-brated liquid-in-glas
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMD727920149626STANDARDTESTMETHODFORKINEMATICVISCOSITYOFTRANSPARENTANDOPAQUELIQUIDSBYAUTOMATEDHOUILLONVISCOMETER

链接地址:http://www.mydoc123.com/p-525031.html