ASTM D6994-2015 3963 Standard Test Method for Determination of Metal Cyanide Complexes in Wastewater Surface Water Groundwater and Drinking Water Using Anion Exchange Chromatograph.pdf
《ASTM D6994-2015 3963 Standard Test Method for Determination of Metal Cyanide Complexes in Wastewater Surface Water Groundwater and Drinking Water Using Anion Exchange Chromatograph.pdf》由会员分享,可在线阅读,更多相关《ASTM D6994-2015 3963 Standard Test Method for Determination of Metal Cyanide Complexes in Wastewater Surface Water Groundwater and Drinking Water Using Anion Exchange Chromatograph.pdf(27页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: D6994 15Standard Test Method forDetermination of Metal Cyanide Complexes in Wastewater,Surface Water, Groundwater and Drinking Water UsingAnion Exchange Chromatography with UV Detection1This standard is issued under the fixed designation D6994; the number immediately following the desig
2、nation indicates the year oforiginal adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope*1.1 This test method covers the de
3、termination of the metalcyanide complexes of iron, cobalt, silver, gold, copper andnickel in waters including groundwaters, surface waters, drink-ing waters and wastewaters by anion exchange chromatogra-phy and UV detection. The use of alkaline sample preservationconditions (see 10.3) ensures that a
4、ll metal cyanide complexesare solubilized and recovered in the analysis (1-3).21.2 Metal cyanide complex concentrations between 0.20 to200 mg/L may be determined by direct injection of the sample.This range will differ depending on the specific metal cyanidecomplex analyte, with some exhibiting grea
5、ter or lesser detec-tion sensitivity than others. Approximate concentration rangesare provided in 12.2. Concentrations greater than the specificanalyte range may be determined after appropriate dilution.This test method is not applicable for matrices with high ionicstrength (conductivity greater tha
6、n 500 meq/L as Cl) and TDS(greater than 30 000 mg/L), such as ocean water.1.3 Metal cyanide complex concentrations less than 0.200mg/L may be determined by on-line sample preconcentrationcoupled with anion exchange chromatography as described in11.3. This range will differ depending on the specific
7、metalcyanide complex analyte, with some exhibiting greater orlesser detection sensitivity than others. Approximate concen-tration ranges are provided in 12.2. The preconcentrationmethod is not applicable for silver and copper cyanide com-plexes in matrices with high TDS (greater than 1000 mg/L).1.4
8、The test method may also be applied to the determina-tion of additional metal cyanide complexes, such as those ofplatinum and palladium. However, it is the responsibility of theuser of this standard to establish the validity of the test methodfor the determination of cyanide complexes of metals othe
9、rthan those in 1.1.1.5 The presence of metal complexes within a sample maybe converted to Metal CN complexes and as such, are alteredwith the use of this method. This method is not applicable tosamples that contain anionic complexes of metals that areweaker than cyanide complexes of those metals.1.6
10、 The values stated in SI units are to be regarded asstandard. The values given in parentheses are mathematicalconversions to inch-pound units that are provided for informa-tion only and are not considered standard.1.7 This standard does not purport to address all of thesafety concerns, if any, assoc
11、iated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use. For specific hazardstatements, refer to Section 9.2. Referenced Documents2.1 ASTM Standards:3D1129 T
12、erminology Relating to WaterD1193 Specification for Reagent WaterD2777 Practice for Determination of Precision and Bias ofApplicable Test Methods of Committee D19 on WaterD3370 Practices for Sampling Water from Closed ConduitsD3856 Guide for Management Systems in LaboratoriesEngaged in Analysis of W
13、aterD5810 Guide for Spiking into Aqueous SamplesD5847 Practice for Writing Quality Control Specificationsfor Standard Test Methods for Water AnalysisD6696 Guide for Understanding Cyanide Species3. Terminology3.1 Definitions:3.1.1 For a definition of terms used in this standard, refer toTerminology D
14、1129.3.2 Definitions of Terms Specific to This Standard:1This test method is under the jurisdiction of ASTM Committee D19 on Waterand is the direct responsibility of Subcommittee D19.05 on Inorganic Constituentsin Water.Current edition approved Oct. 1, 2015. Published October 2015. Originallyapprove
15、d in 2004. Last previous edition approved in 2010 as D6994 10. DOI:10.1520/D6994-15.2The boldface numbers in parentheses refer to the list of references at the end ofthis standard.3For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org
16、. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.*A Summary of Changes section appears at the end of this standardCopyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States13.
17、2.1 anion exchange chromatography, na type of liquidchromatography in which anionic analytes are separated bydifferential retention on an anion exchange resin and detectedby an appropriate detection mechanism.3.2.2 eluent, nthe liquid mobile phase used in anionexchange chromatography to transport th
18、e sample through thechromatography system.3.2.3 analytical column, nthe chromatography columnthat contains the stationary phase for separation by ion ex-change.3.2.3.1 DiscussionThe column is packed with anion ex-change resin that separates the analytes of interest based ontheir retention characteri
19、stics prior to detection.3.2.4 guard column, na short chromatography column thatis placed before the analytical column to protect the latter fromparticulates and impurities that may cause fouling.3.2.5 anion trap column, na high-capacity, low-pressureanion exchange column used to remove reagent impu
20、ritiesfrom the eluent stream.3.2.5.1 DiscussionThe anion trap column is placed be-tween the eluent reservoir and the gradient pump.3.2.6 gradient elution, na type of elution in which theeluent composition is steadily altered throughout the analysisin order to provide for an adequate separation of th
21、e analytes ofinterest prior to detection.3.2.7 gradient pump, na liquid chromatography pump thatis capable of performing gradient elutions.3.2.8 total cyanide, nthe sum total of all of the inorganicchemical forms of cyanide.3.2.8.1 DiscussionTotal cyanide thus includes both freecyanide and anionic m
22、etal cyanide complexes.3.2.9 metal cyanide complex, na negatively charged ioniccomplex consisting of one or more cyanide ions bound to asingle transition metal cation.3.2.9.1 DiscussionAlso referred to as metal-complexedcyanides, these complexes have the general formula:MCN!b#x2(1)where:M = transiti
23、on metal cation,b = number of cyanide groups, andx = ionic charge of the transition metal complex.3.2.9.2 DiscussionMetal cyanide complexes are relativelystable and require moderate to highly acidic conditions in orderto dissociate and form free cyanide. Based on their stability,metal cyanide comple
24、xes are divided into two categories:“weak metal cyanide complexes” and “strong metal cyanidecomplexes.” Examples of strong metal cyanide complexesinclude the iron cyanide complexes prevalent in many cyanidecontaining industrial wastewaters. The iron cyanide complexesare considered to be among the mo
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMD699420153963STANDARDTESTMETHODFORDETERMINATIONOFMETALCYANIDECOMPLEXESINWASTEWATERSURFACEWATERGROUNDWATERANDDRINKINGWATERUSINGANIONEXCHANGECHROMATOGRAPHPDF

链接地址:http://www.mydoc123.com/p-524198.html