ASTM D6654-2018 red 5000 Standard Practice for Basic Storage Stability of a Mechanical Pump Dispenser.pdf
《ASTM D6654-2018 red 5000 Standard Practice for Basic Storage Stability of a Mechanical Pump Dispenser.pdf》由会员分享,可在线阅读,更多相关《ASTM D6654-2018 red 5000 Standard Practice for Basic Storage Stability of a Mechanical Pump Dispenser.pdf(4页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: D6654 05 (Reapproved 2010)D6654 18Standard Test Method Practice forBasic Storage Stability of a Mechanical Pump Dispenser1This standard is issued under the fixed designation D6654; the number immediately following the designation indicates the year oforiginal adoption or, in the case of
2、 revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope1.1 This test method practice covers the determination of the basic storage stability of a mechanic
3、al pump dispenser with aproduct.1.2 This test method practice covers an evaluation of the weight lost during storage of mechanical pump dispensers (spray orflow types) with a product.1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the
4、responsibilityof the user of this standard to establish appropriate safety safety, health, and healthenvironmental practices and determine theapplicability of regulatory limitations prior to use.1.4 This international standard was developed in accordance with internationally recognized principles on
5、 standardizationestablished in the Decision on Principles for the Development of International Standards, Guides and Recommendations issuedby the World Trade Organization Technical Barriers to Trade (TBT) Committee.2. Referenced Documents2.1 ASTM Standards:2D2063 Test Methods for Measurement of Torq
6、ue Retention for Packages with Continuous Thread ClosuresD3890 Practice for Number of Strokes to Prime a Mechanical Pump DispenserD4336 Practice for Determination of the Output Per Stroke of a Mechanical Pump DispenserE122 Practice for Calculating Sample Size to Estimate, With Specified Precision, t
7、he Average for a Characteristic of a Lot orProcess3. Significance and Use3.1 Determining the storage of a mechanical pump dispenser for consumer usage. Products of consumer usage are of thepersonal care, household, insecticides, food, automotive, and institutional nature. Pharmaceutical and cosmetic
8、 products includingperfume are not covered under this practice.4. Apparatus4.1 Containers, that will allow the mechanical pump dispenser to be affixed to them (see Note 1) and also be capable ofcontaining product for a period of time at various environmental conditions (see Note 2).NOTE 1If possible
9、, the actual container to be marketed should be used.4.2 Product, a sufficient amount to fill the number of containers in accordance with 4.1, reference 10.2.4.3 Balance, with direct reading to 0.01 g. Top loading or analytical style is recommended.4.4 Environments, where the mechanical pump dispens
10、er and product will be kept during the test period.4.4.1 Ambient Area, maintained at 23 6 3C (73 6 5.4F).4.4.2 Oven (45C), maintained at 45 6 3C (113 6 5.4F).NOTE 2The oven temperature can be changed according to product formulation. If different temperatures are used, this should be noted in the te
11、streport discussed in 11.1.1 This test method practice is under the jurisdiction ofASTM Committee F02 on FlexiblePrimary Barrier Packaging and is the direct responsibility of Subcommittee F02.30on Mechanical Pump Dispensers.Current edition approved Oct. 1, 2010May 1, 2018. Published March 2011June 2
12、018. Originally approved in 2001. Last previous edition approved in 20052010 asD6654 05. 05(2010). DOI: 10.1520/D6654-05R10.10.1520/D6654-18.2 For referencedASTM standards, visit theASTM website, www.astm.org, or contactASTM Customer Service at serviceastm.org. For Annual Book of ASTM Standardsvolum
13、e information, refer to the standards Document Summary page on the ASTM website.This document is not an ASTM standard and is intended only to provide the user of an ASTM standard an indication of what changes have been made to the previous version. Becauseit may not be technically possible to adequa
14、tely depict all changes accurately, ASTM recommends that users consult prior editions as appropriate. In all cases only the current versionof the standard as published by ASTM is to be considered the official document.Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocke
15、n, PA 19428-2959. United States14.4.3 Cycle Chamber, optional, alternating 5 to 50C (41 to 122F) every 24 h.4.5 Oven-Safe Tray, with absorbent paper towels laid in the tray.4.6 Food Coloring or Dye, optional.5. Precautions5.1 Appropriate handling considerations should be given to flammable, toxic, c
16、austic, or other potentially hazardous materialused. When testing at any temperature, safety should be the number one consideration and special attention should be used on theflash points of the products tested.6. Sampling6.1 Based upon the desired precision, sampling shall be performed in accordanc
17、e with Practice E122.6.2 In the absence of any special sampling plan, performance shall be based on not less than the number of representativespecimens exposed to any of the environmental conditions as specified in Section 9.7. Test Specimens7.1 Test specimens shall be clean, dry, and previously unu
18、sed mechanical pump dispensers.8. Conditioning8.1 If possible, condition the test specimens at 23 6 3C (73 6 5.4F) for not less than 4 h. If the test specimens are notconditioned at the recommended temperature and humidity, this should be noted in the test report discussed in section 11.1.8.2 Test p
19、umps should be tested no sooner than 24 h after assembly when possible. If pumps are not conditioned at therecommended time, this should be noted in the test report discussed in 11.1.9. Test Specimen Preparation9.1 Prepare a minimum of twelve unprimed mechanical pump dispensers with product and cont
20、ainers to be used for evaluation.9.1.1 Label all of the assembled units with the product name, any safety hazards for the product, name of the techniciancompleting the test, and the test number or means of identifying the test along with the following :9.1.1.1 Minimum three units labeled, “Upright,
21、Ambient.”9.1.1.2 Minimum three units labeled, “Upright, Oven 45C”9.1.1.3 OptionalMinimum three units labeled, “Upright, Cycle Chamber.”9.1.1.4 Minimum three units labeled, “On-Side, Ambient.”9.1.1.5 Minimum three units labeled, “On-Side, Oven (45C).”9.1.1.6 OptionalMinimum three units labeled “On-Si
22、de, Cycle Chamber.”NOTE 3Since the output of this test is weight loss of product for the total package of container with a mechanical pump dispenser, it may beadvantages for a control package of the test container with a standard closure to be included at each condition so that the effect of the mec
23、hanical pumpdispenser may be determined.10. Procedure10.1 If the data is to be presented as gross weight lost only, then proceed to 10.2. If the data is to be presented as weight lostas a percentage of the weight of the product, weigh each container with its intended pump at the beginning of testing
24、 and recordthat data on the data sheet as “Unfilled Packaging Weight.” (Tare).10.2 Fill each container with the desired amount of product. The level of product in the container should represent the level usedfor commercial use. To better identify leakage, food coloring or dye may be added.10.3 Affix
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便