ASTM D6382 D6382M-1999(2017) 2705 Standard Practice for Dynamic Mechanical Analysis and Thermogravimetry of Roofing and Waterproofing Membrane Material《屋顶和防水膜材料的热重力和动态机械分析的标准实施规程》.pdf
《ASTM D6382 D6382M-1999(2017) 2705 Standard Practice for Dynamic Mechanical Analysis and Thermogravimetry of Roofing and Waterproofing Membrane Material《屋顶和防水膜材料的热重力和动态机械分析的标准实施规程》.pdf》由会员分享,可在线阅读,更多相关《ASTM D6382 D6382M-1999(2017) 2705 Standard Practice for Dynamic Mechanical Analysis and Thermogravimetry of Roofing and Waterproofing Membrane Material《屋顶和防水膜材料的热重力和动态机械分析的标准实施规程》.pdf(3页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: D6382/D6382M 99 (Reapproved 2017)Standard Practice forDynamic Mechanical Analysis and Thermogravimetry ofRoofing and Waterproofing Membrane Material1This standard is issued under the fixed designation D6382/D6382M; the number immediately following the designation indicates theyear of or
2、iginal adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of lastreapproval. A superscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope1.1 This practice covers test procedures and conditions thatare a
3、pplicable when Test Methods D5023, D5024, D5026,D5279, and D5418 are used for conducting dynamic mechani-cal analysis of roofing and waterproofing membrane material inthree-point bending, compression, tension, torsion, and dualcantilever modes, respectively. The specific method is selectedby the ana
4、lyst and depends on the membrane material and theoperating principles of the individual instrument used for theanalysis.1.2 This practice covers test procedures and conditions thatare applicable when Test Method E1131 is used for conductingthermogravimetry of roofing and waterproofing membranemateri
5、al.1.3 Membrane materials include bituminous built-uproofing, polymer-modified bitumen sheets, vulcanized rubbers,non-vulcanized polymeric sheets, and thermoplastics. Themembrane materials can be either nonreinforced or reinforced.1.4 This practice is applicable to new membrane materialsreceived fro
6、m the supplier, those exposed artificially in thelaboratory or outdoors on an exposure rack, and those sampledfrom field installations.1.5 This practice contains notes which are explanatory andare not part of the mandatory requirements of this practice.1.6 The values stated in either SI units or inc
7、h-pound unitsare to be regarded separately as standard. The values stated ineach system may not be exact equivalents; therefore, eachsystem shall be used independently of the other. Combiningvalues from the two systems may result in non-conformancewith the standard.1.7 This standard does not purport
8、 to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use.1.8 This international standard was developed in
9、accor-dance with internationally recognized principles on standard-ization established in the Decision on Principles for theDevelopment of International Standards, Guides and Recom-mendations issued by the World Trade Organization TechnicalBarriers to Trade (TBT) Committee.2. Referenced Documents2.1
10、 ASTM Standards:2D1079 Terminology Relating to Roofing and WaterproofingD4092 Terminology for Plastics: Dynamic MechanicalPropertiesD5023 Test Method for Plastics: Dynamic Mechanical Prop-erties: In Flexure (Three-Point Bending)D5024 Test Method for Plastics: Dynamic Mechanical Prop-erties: In Compr
11、essionD5026 Test Method for Plastics: Dynamic Mechanical Prop-erties: In TensionD5279 Test Method for Plastics: Dynamic Mechanical Prop-erties: In TorsionD5418 Test Method for Plastics: Dynamic Mechanical Prop-erties: In Flexure (Dual Cantilever Beam)E473 Terminology Relating to Thermal Analysis and
12、 Rhe-ologyE1131 Test Method for Compositional Analysis by Thermo-gravimetryE1142 Terminology Relating to Thermophysical Properties3. Terminology3.1 DefinitionsFor definitions of terms used in thispractice, refer to Terminologies E473, D1079, D4092, andE1142.4. Summary of Practice4.1 In conducting a
13、dynamic mechanical analysis, the roof-ing or waterproofing membrane specimen is placed in a test1This practice is under the jurisdiction ofASTM Committee D08 on Roofing andWaterproofing and is the direct responsibility of Subcommittee D08.20 on RoofingMembrane Systems.Current edition approved May 1,
14、 2017. Published May 2017. Originallyapproved in 1999. Last previous edition approved in 2011 as D6382/D6382M 99(2011)1. DOI: 10.1520/D6382_D6382M-99R17.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMSt
15、andards volume information, refer to the standards Document Summary page onthe ASTM website.Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United StatesThis international standard was developed in accordance with internationally recognized princip
16、les on standardization established in the Decision on Principles for theDevelopment of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.1chamber and subjected to a controlled, increasing temperatureprogram. The tem
17、perature range can be from well-below (forexample, 80C) to somewhat (for example, 50C) aboveroom temperature. The glass transition temperature, storagemodulus, loss modulus, and damping factor of the specimenare measured.4.2 In conducting a thermogravimetry analysis, the roofingor waterproofing memb
18、rane specimen is placed in a testchamber and subjected to a controlled, increasing temperatureprogram. The temperature range can be from about roomtemperature (for example, 20 to 40C) to well-above roomtemperature (for example, 900C), and the atmosphere of thechamber is controlled through the use of
19、 inert gas such asnitrogen or reactive gas such as air. The percent mass loss ofthe specimen is determined as a function of temperature.5. Significance and Use5.1 Dynamic mechanical analysis provides a measure of therheological properties of roofing and waterproofing membranematerials.5.2 Thermograv
20、imetry is used to characterize the thermalstability of roofing and waterproofing membrane materialsunder the specific temperature program and gaseous atmo-sphere conditions selected for the analysis.5.3 Both dynamic mechanical analysis and thermogravim-etry are used to evaluate the effect of either
21、laboratory-simulated or in-service exposure on roofing and waterproofingmembrane materials.5.4 Both dynamic mechanical analysis and thermogravim-etry can be applied to asphalt shingles. However, their appli-cation to asphalt shingles is beyond the scope of this practice,which is limited to low-slope
22、 membrane materials at this time.5.5 This practice can be useful in the development ofperformance criteria for roofing and waterproofing membranematerials.DYNAMIC MECHANICAL ANALYSIS6. Test Procedure6.1 Select the specific test method (that is, Test MethodD5023, D5024, D5026, D5279,orD5418) dependin
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMD6382D6382M199920172705STANDARDPRACTICEFORDYNAMICMECHANICALANALYSISANDTHERMOGRAVIMETRYOFROOFINGANDWATERPROOFINGMEMBRANEMATERIAL

链接地址:http://www.mydoc123.com/p-522352.html