ASTM D7375 - 08 Standard Test Method for Trace Quantities of Water in Aromatic Hydrocarbons and Their Mixtures by Coulometric Karl Fischer Titration (Withdrawn 2017).pdf
《ASTM D7375 - 08 Standard Test Method for Trace Quantities of Water in Aromatic Hydrocarbons and Their Mixtures by Coulometric Karl Fischer Titration (Withdrawn 2017).pdf》由会员分享,可在线阅读,更多相关《ASTM D7375 - 08 Standard Test Method for Trace Quantities of Water in Aromatic Hydrocarbons and Their Mixtures by Coulometric Karl Fischer Titration (Withdrawn 2017).pdf(5页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: D7375 08Standard Test Method forTrace Quantities of Water in Aromatic Hydrocarbons andTheir Mixtures by Coulometric Karl Fischer Titration1This standard is issued under the fixed designation D7375; the number immediately following the designation indicates the year oforiginal adoption o
2、r, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope1.1 This test method describes the use of the CoulometricKarl Fischer (KF) titrati
3、on for the determination of water inaromatic hydrocarbons and their mixtures, derivatives andrelated chemicals.1.2 This test method is applicable to samples with waterconcentrations from 10 to 400 mg/kg.1.3 In determining the conformance of the test results usingthis method to applicable specificati
4、ons, results shall berounded off in accordance with the rounding-off method ofPractice E29.1.4 Values stated in SI units are to be regarded as thestandard. The preferred units are milligrams per kilogram(mg/kg).1.5 This standard does not purport to address all of thesafety concerns, if any, associat
5、ed with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use. For a specifichazard statement see Section 8.2. Referenced Documents2.1 ASTM Standards:2D1193 Specifica
6、tion for Reagent WaterD3437 Practice for Sampling and Handling Liquid CyclicProductsD6809 Guide for Quality Control and Quality AssuranceProcedures for Aromatic Hydrocarbons and Related Ma-terialsE29 Practice for Using Significant Digits in Test Data toDetermine Conformance with SpecificationsE203 T
7、est Method for Water Using Volumetric Karl FischerTitration2.2 Other Standard:OSHARegulations, 29 CFR paragraphs 1910 and 1910.120033. Summary of Test Method3.1 In the Karl Fischer reaction, water will react with iodinein the presence of sulfur dioxide, alcohol and an organic baseaccording to the fo
8、llowing equation:H2O1I21SO21CH3OH13RNRNH!SO4CH312RNH!I (1)where:RN = organic base.3.2 In the coulometric titration test method, the sample isinjected into an electrolytic cell where the iodine required forthe reaction with water is produced by an anodic oxidation ofiodide. With this technique, no st
9、andardization of reagents isrequired.4. Significance and Use4.1 High water concentrations can have a detrimental effecton many uses of aromatic hydrocarbons, their mixtures andrelated compounds.4.2 Water can inhibit desired reactions when aromatichydrocarbons, their mixtures and related compounds ar
10、e usedin formulations and chemical processes.4.3 Water can cause corrosion problems and detrimentaleffects during the manufacture and processing of aromatichydrocarbons, their mixtures and related compounds.5. Interferences5.1 Certain compounds or classes of compounds interferewith the accurate dete
11、rmination of water by the Karl Fischertest method. They include aldehydes, ketones, free halogens,ferric salts and strong oxidizing and reducing agents.5.2 Free halogens can oxidize the iodate in the KF reagentsto form iodine: this causes erroneously low water values.1This test method is under the j
12、urisdiction of ASTM Committee D16 onAromatic Hydrocarbons and Related Chemicals and is the direct responsibility ofSubcommittee D16.04 on Instrumental Analysis.Current edition approved Jan. 1, 2008. Published February 2008. DOI: 10.1520/D7375-08.2For referenced ASTM standards, visit the ASTM website
13、, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.3Available from U.S. Government Printing Office Superintendent of Documents,732 N. Capitol St., NW, Mail Stop: SDE,
14、 Washington, DC 20401, http:/www.access.gpo.gov.Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United StatesNOTICE: This standard has either been superseded and replaced by a new version or withdrawn.Contact ASTM International (www.astm.org) for t
15、he latest information15.3 A more detailed discussion of KF interferences can befound in Test Method E203 and other sources.46. Apparatus6.1 Coulometric TitratorConsisting of a single or dualbath electrolytic cell, dual platinum electrode, magnetic stirrerand control unit.6.1.1 Dual Bath Electrolytic
16、 CellThe dual bath coulom-etic titration cell consists of a sealed vessel containing both ananode and cathode compartment (a Fritted Cathode Cell). Theanodic compartment usually contains a solution consisting ofsulfur dioxide, iodide and an amine in an alcoholic basedsolvent. The cathodic compartmen
17、t contains similar reagentsoptimized for the cathodic reduction. When a sample contain-ing water is injected into the anode compartment, the electro-lytic cell generates its own supply of iodine from the iodidepresent. The iodine reacts stoichiometrically with the water andthe completion of the reac
18、tion is detected with a dual platinum-sensing electrode. The coulombs of electricity required togenerate the necessary amount of iodine is then translated bythe microprocessor in the control unit into the amount of waterthat was present in the sample.6.1.2 Single Bath Electrolytic Cell The single ba
19、th elec-trolytic cell consist of a sealed vessel with an anode andcathode electrode (a Frittless Cathode Cell), a dual platinumsensing electrode and is filled with a single bath reagent. Whena sample containing water is injected into the vessel, theelectrolytic cell generates its own supply of iodin
20、e from theiodide present. The iodine reacts stoichiometrically with thewater and the completion of the reaction is detected with a dualplatinum-sensing electrode. The coulombs of electricity re-quired to generate the necessary amount of iodine is thentranslated by the microprocessor in the control u
21、nit into theamount of water that was present in the sample.6.2 Sampling Syringes5 and 10-mL gastight syringes.6.3 Standard Gastight Syringe10-L size.6.4 Silicone Rubber Blocks Silicone Rubber Septa, orequivalent.6.5 Drying OvenAir circulating capable of maintaining adrying temperature of 110C.6.6 De
22、siccator with desiccant.6.7 Analytical BalanceCapable of weighing to the nearest0.0001 g accurately.7. Reagents and Materials7.1 Purity of ReagentsReagent grade chemicals shall beused in all tests. Unless otherwise indicated, it is intended thatall reagents shall conform to the specifications of the
23、AmericanChemical Society where such specifications are available.5Other grades may be used, providing it is first ascertained thatthe reagent is of sufficiently high purity to permit its usewithout lessening the accuracy of the determination.7.2 Purity of WaterUnless otherwise indicated referencesto
24、 water shall be understood to mean reagent water conformingto Type II of Specification D1193.7.3 Anode ReagentFor dual bath titration use reagentrecommended by manufacturer of titrator.7.4 Cathode ReagentFor dual bath titration use reagentrecommended by manufacturer of titrator.7.5 Single Bath Reage
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTM D7375 08 Standard Test Method for Trace Quantities of Water in Aromatic Hydrocarbons and Their Mixtures by Coulometric Karl Fischer Titration Withdrawn 2017

链接地址:http://www.mydoc123.com/p-286990.html