ASTM D6176-1997(2003) Standard Practice for Measuring Surface Atmospheric Temperature with Electrical Resistance Temperature Sensors《用电阻温度感应器测量表面大气温度的标准规程》.pdf
《ASTM D6176-1997(2003) Standard Practice for Measuring Surface Atmospheric Temperature with Electrical Resistance Temperature Sensors《用电阻温度感应器测量表面大气温度的标准规程》.pdf》由会员分享,可在线阅读,更多相关《ASTM D6176-1997(2003) Standard Practice for Measuring Surface Atmospheric Temperature with Electrical Resistance Temperature Sensors《用电阻温度感应器测量表面大气温度的标准规程》.pdf(5页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: D 6176 97 (Reapproved 2003)Standard Practice forMeasuring Surface Atmospheric Temperature with ElectricalResistance Temperature Sensors1This standard is issued under the fixed designation D 6176; the number immediately following the designation indicates the year oforiginal adoption or,
2、 in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon (e) indicates an editorial change since the last revision or reapproval.1. Scope1.1 This practice provides procedures to measure represen-tative near-surface atmos
3、pheric (outdoor air) temperature formeteorological purposes using commonly available electricalthermometers housed in radiation shields mounted on station-ary or portable masts or towers.1.2 This practice is applicable for measurements over thetemperature range normally encountered in the ambient at
4、mo-sphere, 50 to +50C.1.3 Air temperature measurement systems include a radia-tion shield, resistance thermometer, signal cables, and associ-ated electronics.1.4 Measurements can be made at a single level for variousmeteorological purposes, at two or more levels for verticaltemperature differences,
5、and using special equipment (at one ormore levels) for fluctuations of temperature with time appliedto flux or variance measurements.1.5 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to estab
6、lish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use.2. Referenced Documents2.1 ASTM Standards:2D 1356 Terminology Relating to Sampling and Analysis ofAtmospheresE 344 Terminology Relating to Thermometry and Hydrom-etryE 644 Test Metho
7、ds for Testing Industrial Resistance Ther-mometersE 1137 Specification for Industrial Platinum ResistanceThermometers3. Terminology3.1 For definitions of terms used in this practice, refer toTerminology D 1356 and E 344. Some definitions are repeatedin this section for the readers convenience.3.1.1
8、connecting wiresthe wires which run from theelement through the cable end closure and external to thesheath.3.1.2 interchangeabilitythe extent to which the thermom-eter matches a resistance-temperature relationship.3.1.3 inversionthe increase in potential temperature withan increase in height (see 3
9、.1.4 and 3.2.7).3.1.4 lapse ratethe change in temperature with an in-crease in height (see 3.1.3 and 3.2.7).3.1.5 resistance thermometera temperature-measuringdevice comprised of a resistance thermometer element, internalconnecting wires, a protective shell with or without means formounting, a conne
10、ction head or connecting wire with otherfittings, or both (see also 3.2.3).3.1.6 resistance thermometer elementthe temperature-sensitive portion of the thermometer composed of resistancewire, film or semiconductor material, its supporting structure,and the means for attaching connecting wires.3.1.7
11、thermistora semiconductor whose primary functionis to exhibit a monotonic change (generally a decrease) inelectrical resistance with an increase in sensor temperature.3.2 Definitions of Terms Specific to This Standard:3.2.1 ambientthe portion of the atmosphere where the airtemperature is unaffected
12、by local structural, terrain, or heatsource or sink influences.3.2.2 sensorused interchangeably with resistance ther-mometer (see 3.1.5) in this practice.3.2.3 shielda ventilated housing designed to minimize theeffects of solar and terrestrial radiation on a temperature sensorwhile maximizing convec
13、tive heat transfer between the sensorand the passing air, and to protect the sensor from contact withliquid moisture; also known as radiation shield.3.2.4 temperature differentialthe difference between twoor more simultaneous temperature measurements, typicallyseparated vertically at a single locati
14、on; see 3.1.3 and 3.1.4.1This practice is under the jurisdiction of ASTM Committee D22 on Samplingand Analysis of Atmospheres and is the direct responsibility of SubcommitteeD22.11 on Meteorology.Current edition approved October 1, 2003. Published November 2003. Originallyapproved in 1997. Last prev
15、ious edition approved in 1997 as D 6176M - 97.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.1Copyright ASTM
16、 International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.3.2.5 temperature variancea statistical measure, the de-viation of individual temperature measurements from the meanof those measurements obtained over a user-defined samplingperiod.3.2.5.1 Discussion
17、Temperature variance describes tem-perature variability at a fixed point in the atmosphere. Thecovariance of temperature and vertical velocity defines thesensible heat flux.3.2.6 transfer functionthe functional relationship betweentemperature sensor electrical resistance and the correspondingsensor
18、temperature.3.2.7 vertical temperature gradientthe change of tem-perature with height (DT/DZordT/dZ), frequently expressed inC/m; also known as lapse rate for temperature decrease, orinversion for a temperature increase (see 3.1.3 and 3.1.4).3.3 Symbols:agl = above ground levelDT = difference betwee
19、n two temperatures, also dTDZ = difference between two heights above ground level,also dZT = temperature, degrees in appropriate scale, typicallyCelsius, CZ = height above ground level, typically metrest = time constant, the time for a sensor to change toapproximately 63.2 % (1l/e) of the value of t
20、hetemperature change.4. Significance and Use4.1 ApplicationsAmbient atmospheric temperature mea-surements can be made using resistance thermometers formany purposes. The application determines the most appropri-ate type of resistance thermometer and data recording methodto be used. Examples of three
21、 typical meteorological applica-tions for temperature measurements follow.4.1.1 Single-level, near-surface measurements for weatherobservations (1)3, thermodynamic computations for industrialapplications, or environmental studies (2).4.1.2 Temperature differential or vertical gradient measure-ments
22、to characterize atmospheric stability for atmosphericdispersion analyses studies (2).4.1.3 Temperature fluctuations for heat flux or temperature,or variance computations, or both. Measurements of heat fluxand temperature variance require high precision measurementswith a fast response to changes in
23、the ambient atmosphere.4.2 PurposeThis practice is designed to assist the user inselecting an appropriate temperature measurement system forthe intended atmospheric application, and properly installingand operating the system. The manufacturers recommenda-tions and the U.S. Environmental Protection
24、Agency handbookon quality assurance in meteorological measurements (3)should be consulted for calibration and performance auditprocedures.5. Summary of Practice5.1 Ambient air temperature measurements using resistancethermometers are typically made using either thermistors orplatinum wire or film se
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMD617619972003STANDARDPRACTICEFORMEASURINGSURFACEATMOSPHERICTEMPERATUREWITHELECTRICALRESISTANCETEMPERATURESENSORS

链接地址:http://www.mydoc123.com/p-521774.html