ASTM D5116-2017 Standard Guide for Small-Scale Environmental Chamber Determinations of Organic Emissions from Indoor Materials Products《小型环境室法测定室内材料 制品中挥发性有机物排放的标准指南》.pdf
《ASTM D5116-2017 Standard Guide for Small-Scale Environmental Chamber Determinations of Organic Emissions from Indoor Materials Products《小型环境室法测定室内材料 制品中挥发性有机物排放的标准指南》.pdf》由会员分享,可在线阅读,更多相关《ASTM D5116-2017 Standard Guide for Small-Scale Environmental Chamber Determinations of Organic Emissions from Indoor Materials Products《小型环境室法测定室内材料 制品中挥发性有机物排放的标准指南》.pdf(17页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: D5116 17Standard Guide forSmall-Scale Environmental Chamber Determinations ofOrganic Emissions from Indoor Materials/Products1This standard is issued under the fixed designation D5116; the number immediately following the designation indicates the year oforiginal adoption or, in the cas
2、e of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope1.1 This guide provides direction on the measurement of theemissions of volatile organic compou
3、nds (VOCs) from indoormaterials and products using small-scale environmental testchambers.1.2 This guide pertains to chambers that fully enclose amaterial specimen to be tested and does not address otheremission chamber designs such as emission cells (see insteadPractice D7143).1.3 As an ASTM standa
4、rd, this guide describes options, butdoes not recommend specific courses of action. This guide isnot a standard test method and must not be construed as such.1.4 The use of small environmental test chambers to char-acterize the emissions of VOCs from indoor materials andproducts is still evolving. M
5、odifications and variations inequipment, testing procedures, and data analysis are made asthe work in the area progresses. For several indoor materials,more detailedASTM standards for emissions testing have nowbeen developed. Where more detailed ASTM standard prac-tices or methods exist, they supers
6、ede this guide and should beused in its place. Until the interested parties agree uponstandard testing protocols, differences in approach will occur.This guide will continue to provide assistance by describingequipment and techniques suitable for determining organicemissions from indoor materials. S
7、pecific examples are pro-vided to illustrate existing approaches; these examples are notintended to inhibit alternative approaches or techniques thatwill produce equivalent or superior results.1.5 Small chambers have obvious limitations. Normally,only samples of larger materials (for example, carpet
8、) aretested. Small chambers are not applicable for testing completeassemblages (for example, furniture). Small chambers are alsoinappropriate for testing combustion devices (for example,kerosene heaters) or activities (for example, use of aerosolspray products). For some products, small chamber test
9、ing mayprovide only a portion of the emission profile of interest. Forexample, the rate of emissions from the application of highsolvent materials (for example, paints and waxes) by means ofbrushing, spraying, rolling, etc. are generally higher than therate during the drying process. Small chamber t
10、esting cannotbe used to evaluate the application phase of the coatingprocess. Large (or full-scale) chambers may be more appropri-ate for many of these applications. For guidance on full-scalechamber testing of emissions from indoor materials refer toPractice D6670.1.6 This guide does not provide sp
11、ecific directions for theselection of sampling media or for the analysis of VOCs. Thisinformation is provided in Practice D6196.1.7 This guide does not provide specific directions fordetermining emissions of formaldehyde from composite woodproducts, since chamber testing methods for such emissions a
12、rewell developed and widely used. For more information refer toTest Methods E1333 and D6007. It is possible, however, thatthe guide can be used to support alternative testing methods.1.8 This guide is not applicable to the determination ofemissions of semi-volatile organic compounds (SVOCs) frommate
13、rials/products largely due to adsorption of these com-pounds on materials commonly used for construction ofchambers suitable for VOC emissions testing. Alternate proce-dures are required for SVOCs. For example, it may be possibleto screen materials for emissions of SVOCs using micro-scalechambers op
14、erated at temperatures above normal indoor con-ditions (see Practice D7706).1.9 This guide is applicable to the determination of emis-sions from products and materials that may be used indoors.The effects of the emissions (for example, toxicity) are notaddressed and are beyond the scope of the guide
15、. Guide D6485provides an example of the assessment of acute and irritanteffects of VOC emissions for a given material. Specification of“target” organic species of concern is similarly beyond thescope of this guide. As guideline levels for specific indoorcontaminants develop, so too will emission tes
16、t protocols toprovide relevant information. Emissions databases and mate-rial labeling schemes will also be expected to adjust to reflectthe current state of knowledge.1This guide is under the jurisdiction of ASTM Committee D22 on Air Qualityand is the direct responsibility of Subcommittee D22.05 on
17、 Indoor Air.Current edition approved Nov. 1, 2017. Published November 2017. Originallyapproved in 1990. Last previous edition approved in 2010 as D5116 10. DOI:10.1520/D5116-17.Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United StatesThis inter
18、national standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for theDevelopment of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Com
19、mittee.11.10 Specifics related to the acquisition, handling,conditioning, preparation, and testing of individual test speci-mens may vary depending on particular study objectives.Guidelines for these aspects of emissions testing are providedhere, specific direction is not mandated. The purpose of th
20、isguide is to increase the awareness of the user to availabletechniques for evaluating organic emissions from indoormaterials/products by means of small chamber testing, toidentify the essential aspects of emissions testing that must becontrolled and documented, and therefore to provideinformation,
21、which may lead to further evaluation and stan-dardization.1.11 Within the context of the limitations discussed in thissection, the purpose of this guide is to describe the methodsand procedures for determining organic emission rates fromindoor materials/products using small environmental testchamber
22、s. The techniques described are useful for both routineproduct testing by manufacturers and testing laboratories andfor more rigorous evaluation by indoor air quality (IAQ)researchers. Appendix X1 provides references to standards thatare widely employed to measure emissions of VOCs frommaterials and
23、 products used in the interiors of buildings. Someof these standards directly reference this guide.1.12 The values stated in SI units are to be regarded asstandard. No other units of measurement are included in thisstandard.1.13 This standard does not purport to address all of thesafety concerns, if
24、 any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety, health, and environmental practices and deter-mine the applicability of regulatory limitations prior to use.1.14 This international standard was developed in accor-dance with interna
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMD51162017STANDARDGUIDEFORSMALLSCALEENVIRONMENTALCHAMBERDETERMINATIONSOFORGANICEMISSIONSFROMINDOORMATERIALSPRODUCTS

链接地址:http://www.mydoc123.com/p-518905.html