ASTM D5116-2010 Standard Guide for Small-Scale Environmental Chamber Determinations of Organic Emissions From Indoor Materials Products《室内材料 产品有机物排放的小规模环境试验室的标准指南》.pdf
《ASTM D5116-2010 Standard Guide for Small-Scale Environmental Chamber Determinations of Organic Emissions From Indoor Materials Products《室内材料 产品有机物排放的小规模环境试验室的标准指南》.pdf》由会员分享,可在线阅读,更多相关《ASTM D5116-2010 Standard Guide for Small-Scale Environmental Chamber Determinations of Organic Emissions From Indoor Materials Products《室内材料 产品有机物排放的小规模环境试验室的标准指南》.pdf(16页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: D5116 10Standard Guide forSmall-Scale Environmental Chamber Determinations ofOrganic Emissions from Indoor Materials/Products1This standard is issued under the fixed designation D5116; the number immediately following the designation indicates the year oforiginal adoption or, in the cas
2、e of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope1.1 This guide provides guidance on determination of emis-sions of organic compounds from indoo
3、r materials and prod-ucts using small-scale environmental test chambers.1.2 This guide pertains to chambers that fully enclose amaterial specimen to be tested and does not address otheremission chamber designs such as emission cells (see insteadPractice D7143).1.3 As an ASTM standard, this guide des
4、cribes options, butdoes not recommend specific courses of action. This guide isnot a standard test method and must not be construed as such.1.4 The use of small environmental test chambers to char-acterize the organic emissions of indoor materials and productsis still evolving. Modifications and var
5、iations in equipment,testing procedures, and data analysis are made as the work inthe area progresses. For several indoor materials, more detailedASTM standards for emissions testing have now been devel-oped. Where more detailed ASTM standard practices ormethods exist, they supersede this guide and
6、should be used inits place. Until the interested parties agree upon standardtesting protocols, differences in approach will occur.This guidewill continue to provide assistance by describing equipmentand techniques suitable for determining organic emissionsfrom indoor materials. Specific examples are
7、 provided toillustrate existing approaches; these examples are not intendedto inhibit alternative approaches or techniques that will pro-duce equivalent or superior results.1.5 Small chambers have obvious limitations. Normally,only samples of larger materials (for example, carpet) aretested. Small c
8、hambers are not applicable for testing completeassemblages (for example, furniture). Small chambers are alsoinappropriate for testing combustion devices (for example,kerosene heaters) or activities (for example, use of aerosolspray products). For some products, small chamber testing mayprovide only
9、a portion of the emission profile of interest. Forexample, the rate of emissions from the application of highsolvent materials (for example, paints and waxes) via brushing,spraying, rolling, etc. are generally higher than the rate duringthe drying process. Small chamber testing can not be used toeva
10、luate the application phase of the coating process. Large (orfull-scale) chambers may be more appropriate for many ofthese applications. For guidance on full-scale chamber testingof emissions from indoor materials refer to Practice D6670.1.6 This guider does not provide specific guidance for thesele
11、ction of sampling media or for the analysis of volatileorganics. This information is provided in Practice D6196.1.7 The guide does not provide specific guidance for deter-mining emissions of formaldehyde from pressed wood prod-ucts, since large chamber testing methods for such emissionsare well deve
12、loped and widely used. For more informationrefer to Test Method E1333. It is possible, however, that theguide could be used to support alternative testing methods.1.8 This guide is applicable to the determination of emis-sions from products and materials that may be used indoors.The effects of the e
13、missions (for example, toxicity) are notaddressed and are beyond the scope of the guide. Guide D6485provides an example of the assessment of acute and irritanteffects of VOC emissions for a given material. Specification of“target” organic species of concern is similarly beyond thescope of this guide
14、. As guideline levels for specific indoorcontaminants develop, so too will emission test protocols toprovide relevant information. Emissions databases and mate-rial labeling schemes will also be expected to adjust to reflectthe current state of knowledge.1.9 Specifics related to the acquisition, han
15、dling, condition-ing, preparation, and testing of individual test specimens mayvary depending on particular study objectives. Guidelines forthese aspects of emissions testing are provided here, specificdirection is not mandated. The purpose of this guide is toincrease the awareness of the user to av
16、ailable techniques forevaluating organic emissions from indoor materials/productsvia small chamber testing, to identify the essential aspects ofemissions testing that must be controlled and documented, andtherefore to provide information, which may lead to furtherevaluation and standardization.1.10
17、Within the context of the limitations discussed in thissection, the purpose of this guide is to describe the methodsand procedures for determining organic emission rates fromindoor materials/products using small environmental test1This guide is under the jurisdiction of ASTM Committee D22 on Air Qua
18、lityand is the direct responsibility of Subcommittee D22.05 on Indoor Air.Current edition approved April 1, 2010. Published April 2010. Originallyapproved in 1990. Last previous edition approved in 2006 as D5116 - 06. DOI:10.1520/D5116-10.1Copyright ASTM International, 100 Barr Harbor Drive, PO Box
19、C700, West Conshohocken, PA 19428-2959, United States.chambers. The techniques described are useful for both routineproduct testing by manufacturers and testing laboratories andfor more rigorous evaluation by indoor air quality (IAQ)researchers. Appendix X1 provides additional references forreaders
20、wishing to supplement the information contained inthis guide.1.11 The values stated in SI units are to be regarded asstandard.1.12 This standard does not purport to address the safetyconcerns, if any, associated with its use. It is the responsibilityof the user of this standard to establish appropri
21、ate safety andhealth practices and determine the applicability of regulatorylimitations prior to use.2. Referenced Documents2.1 ASTM Standards:2D1193 Specification for Reagent WaterD1356 Terminology Relating to Sampling and Analysis ofAtmospheresD1914 Practice for Conversion Units and Factors Relati
22、ngto Sampling and Analysis of AtmospheresD3195 Practice for Rotameter CalibrationD3609 Practice for Calibration Techniques Using Perme-ation TubesD3686 Practice for Sampling Atmospheres to Collect Or-ganic Compound Vapors (Activated Charcoal Tube Ad-sorption Method)D3687 Practice for Analysis of Org
23、anic Compound VaporsCollected by the Activated Charcoal Tube AdsorptionMethodD6177 Practice for Determining Emission Profiles of Vola-tile Organic Chemicals Emitted from Bedding SetsD6196 Practice for Selection of Sorbents, Sampling, andThermal Desorption Analysis Procedures for Volatile Or-ganic Co
24、mpounds in AirD6330 Practice for Determination of Volatile Organic Com-pounds (Excluding Formaldehyde) Emissions from Wood-Based Panels Using Small Environmental Chambers Un-der Defined Test ConditionsD6485 Guide for Risk Characterization ofAcute and IrritantEffects of Short-Term Exposure to Volatil
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMD51162010STANDARDGUIDEFORSMALLSCALEENVIRONMENTALCHAMBERDETERMINATIONSOFORGANICEMISSIONSFROMINDOORMATERIALSPRODUCTS

链接地址:http://www.mydoc123.com/p-518904.html