ASTM D5002-2013 Standard Test Method for Density and Relative Density of Crude Oils by Digital Density Analyzer《采用数字密度分析仪的原油密度和相对密度的标准试验方法》.pdf
《ASTM D5002-2013 Standard Test Method for Density and Relative Density of Crude Oils by Digital Density Analyzer《采用数字密度分析仪的原油密度和相对密度的标准试验方法》.pdf》由会员分享,可在线阅读,更多相关《ASTM D5002-2013 Standard Test Method for Density and Relative Density of Crude Oils by Digital Density Analyzer《采用数字密度分析仪的原油密度和相对密度的标准试验方法》.pdf(6页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: D5002 99 (Reapproved 2010)D5002 13Standard Test Method forDensity and Relative Density of Crude Oils by DigitalDensity Analyzer1This standard is issued under the fixed designation D5002; the number immediately following the designation indicates the year oforiginal adoption or, in the c
2、ase of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope Scope*1.1 This test method covers the determination of the density or relative density of cr
3、ude oils that can be handled in a normalfashion as liquids at test temperatures between 15 and 35C. This test method applies to crude oils with high vapor pressuresprovided appropriate precautions are taken to prevent vapor loss during transfer of the sample to the density analyzer.1.2 This test met
4、hod was evaluated in round robin testing using crude oils in the 0.75 to 0.95 g/mL range. Lighter crude oil canrequire special handling to prevent vapor losses. Heavier crudes can require measurements at higher temperatures to eliminate airbubbles in the sample.1.3 The values stated in SI units are
5、to be regarded as standard. No other units of measurement are included in this standard.The accepted units of measurement of density are grams per millilitre and kilograms per cubic metre.1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is
6、 the responsibilityof the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatorylimitations prior to use. Specific warning statements are given in 7.4, 7.5, and 7.6.2. Referenced Documents2.1 ASTM Standards:2D941 Test Method for Densi
7、ty and Relative Density (Specific Gravity) of Liquids by Lipkin Bicapillary Pycnometer (Withdrawn1993)3D1193 Specification for Reagent WaterD1217 Test Method for Density and Relative Density (Specific Gravity) of Liquids by Bingham PycnometerD1250 Guide for Use of the Petroleum Measurement TablesD40
8、52 Test Method for Density, Relative Density, and API Gravity of Liquids by Digital Density MeterD4057 Practice for Manual Sampling of Petroleum and Petroleum ProductsD4177 Practice for Automatic Sampling of Petroleum and Petroleum ProductsD4377 Test Method for Water in Crude Oils by Potentiometric
9、Karl Fischer Titration3. Terminology3.1 Definitions:3.1.1 densitymass per unit volume at a specified temperature.3.1.2 relative densitythe ratio of the density of a material at a stated temperature to the density of water at a stated temperature.4. Summary of Test Method4.1 Approximately 0.7 mL 1 mL
10、 to 2 mL of crude oil sample is introduced into an oscillating sample tube and the change inoscillating frequency caused by the change in the mass of the tube is used in conjunction with calibration data to determine thedensity of the sample.1 This test method is under the jurisdiction of ASTM Commi
11、ttee D02 on Petroleum Products Products, Liquid Fuels, and Lubricants and is the direct responsibility ofSubcommittee D02.04.0D on Physical and Chemical Methods.Current edition approved Sept. 15, 2010Oct. 1, 2013. Published November 2010October 2013. Originally approved in 1989. Last previous editio
12、n approved in 20052010as D500299(2005).D5002 99 (2010). DOI: 10.1520/D5002-99R10.10.1520/D5002-13.2 For referencedASTM standards, visit theASTM website, www.astm.org, or contactASTM Customer Service at serviceastm.org. For Annual Book of ASTM Standardsvolume information, refer to the standards Docum
13、ent Summary page on the ASTM website.3 The last approved version of this historical standard is referenced on www.astm.org.This document is not an ASTM standard and is intended only to provide the user of an ASTM standard an indication of what changes have been made to the previous version. Becausei
14、t may not be technically possible to adequately depict all changes accurately, ASTM recommends that users consult prior editions as appropriate. In all cases only the current versionof the standard as published by ASTM is to be considered the official document.*A Summary of Changes section appears a
15、t the end of this standardCopyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States15. Significance and Use5.1 Density is a fundamental physical property that can be used in conjunction with other properties to characterize the qualityof crude
16、oils.5.2 The density or relative density of crude oils is used for the conversion of measured volumes to volumes at the standardtemperatures of 15C or 60F and for the conversion of crude mass measurements into volume units.5.3 The application of the density result obtained from this test method, for
17、 fiscal or custody transfer accounting calculations,can require measurements of the water and sediment contents obtained on similar specimens of the crude oil parcel.6. Apparatus6.1 Digital Density AnalyzerA digital analyzer consisting of a U-shaped, oscillating sample tube and a system for electron
18、icexcitation, frequency counting, and display. The analyzer must accommodate the accurate measurement of the sample temperatureduring measurement or must control the sample temperature as described in 6.2 and 6.5.The instrument shall be capable of meetingthe precision requirements described in Test
19、Method D4052.6.2 Circulating Constant-Temperature Bath, capable of maintaining the temperature of the circulating liquid constant to60.05C in the desired range. Temperature control can be maintained as part of the density analyzer instrument package.6.3 Syringes, at least 2 mL in volume with a tip o
20、r an adapter tip that will fit the inlet of the density analyzer.6.4 Flow-Through or Pressure Adapter, for use as an alternative means of introducing the sample into the density meter.6.5 Thermometer, calibrated and graduated to 0.1C, and a thermometer holder that can be attached to the instrument f
21、or settingand observing the test temperature. In calibrating the thermometer, the ice point and bore corrections should be estimated to thenearest 0.05C. Precise setting and control of the test temperature in the sample tube is extremely important. An error of 0.1Ccan result in a change in density o
22、f one in the fourth significant figure.7. Reagents and Materials7.1 Purity of ReagentsReagent grade chemicals shall be used in all tests. Unless otherwise indicated it is intended that allreagents shall conform to the specifications of the Committee on Analytical Reagents of the American Chemical So
23、ciety, wheresuch specifications are available.4 Other grades may be used, provided it is first ascertained that the reagent is of sufficiently highpurity to permit its use without lessening the accuracy of the determination.7.2 Purity of WaterUnless otherwise indicated, references to water shall be
24、understood to mean reagent water as defined byType II of Specification D1193.7.3 Water, redistilled, freshly boiled and cooled reagent water for use as a primary calibration standard. (WarningHandlingwater at boiling or near boiling temperature can present a safety hazard. Wear appropriate personal
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMD50022013STANDARDTESTMETHODFORDENSITYANDRELATIVEDENSITYOFCRUDEOILSBYDIGITALDENSITYANALYZER 采用 数字

链接地址:http://www.mydoc123.com/p-518622.html