ASTM D4892-1989(2009) Standard Test Method for Density of Solid Pitch (Helium Pycnometer Method)《固体硬沥青密度的标准试验方法(氦比重瓶比重测定法)》.pdf
《ASTM D4892-1989(2009) Standard Test Method for Density of Solid Pitch (Helium Pycnometer Method)《固体硬沥青密度的标准试验方法(氦比重瓶比重测定法)》.pdf》由会员分享,可在线阅读,更多相关《ASTM D4892-1989(2009) Standard Test Method for Density of Solid Pitch (Helium Pycnometer Method)《固体硬沥青密度的标准试验方法(氦比重瓶比重测定法)》.pdf(3页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: D 4892 89 (Reapproved 2009)An American National StandardStandard Test Method forDensity of Solid Pitch (Helium Pycnometer Method)1This standard is issued under the fixed designation D 4892; the number immediately following the designation indicates the year oforiginal adoption or, in th
2、e case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.This standard has been approved for use by agencies of the Department of Defense.1. Scope1.1 This
3、test method covers the determination of pitchdensity by helium pycnometer. It is applicable at a range ofroom temperatures of 15 to 35C.1.2 The values stated in SI units are to be regarded asstandard. No other units of measurement are included in thisstandard.1.3 This standard does not purport to ad
4、dress all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use.2. Referenced Documents2.1 ASTM Standards:2D71 Test Met
5、hod for Relative Density of Solid Pitch andAsphalt (Displacement Method)D 2320 Test Method for Density (Relative Density) of SolidPitch (Pycnometer Method)D 2962 Test Method for Calculating Volume-TemperatureCorrection For Coal-Tar PitchesD 4296 Practice for Sampling PitchE11 Specification for Woven
6、 Wire Test Sieve Cloth andTest Sieves3. Terminology3.1 Definition of Term Specific to this Standard:3.1.1 density, as determined by this test methodthe massper unit volume and shall be reported as follows:density, 25C, g/cm3grams per cubic centimeter! (1)4. Summary of Test Method4.1 The sample is pu
7、lverized and screened to a givenfraction, then the volume of a weighed portion of the fractionis determined using a helium pycnometer.5. Significance and Use5.1 This test method is useful in characterizing pitches asone element in establishing uniformity of shipments andsources of supply. With this
8、method, the density is determinedto two decimal places, which is sufficient for most applications.If a more precise measurement is required (three decimalplaces), use Test Methods D 2320 or D71.6. Apparatus6.1 Helium Pycnometer.36.2 Balance, capable of weighing a 150-g specimen towithin 1 mg.6.3 Sie
9、ves, U.S. Standard 2.36-mm (No. 8), 600-m (No.30), conforming to Specification E11.6.4 Thermometer, for measuring room temperature.7. Bulk Sampling7.1 Samples from shipments shall be taken in accordancewith Practice D 4296 and shall be free of foreign substances.8. Dehydration8.1 All bulk samples su
10、spected of having free moistureshould be air-dried or oven-dried at 50C in a convection orforced-air oven before analyzing.9. Preparation of Test Specimen9.1 Crush a 50 to 200-g representative portion of the drypitch until all of it passes the 2.36 mm (No. 8 sieve). Avoid1This test method is under t
11、he jurisdiction of ASTM Committee D02 onPetroleum Products and Lubricants and is the direct responsibility of SubcommitteeD02.05 on Properties of Fuels, Petroleum Coke and Carbon Material.Current edition approved April 15, 2009. Published July 2009. Originallyapproved in 1989. Last previous edition
12、approved in 2004 as D 489289(2004).2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.3Helium pycnometers availa
13、ble from the following suppliers have been foundsatisfactory for this purpose: (a) Beckman 2500 Harbor Blvd., Fullerton, CA, (b)Micromeritics, 5680 Goshen Springs Rd., Norcross, GA, and (c) Quantachrome, 5Aerial Way, Syosset, NY. If you are aware of alternative suppliers, please providethis informat
14、ion to ASTM International Headquarters. Your comments will receivecareful consideration at a meeting of the responsible technical committee1, whichyou may attend.1Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.grinding the pitch. Rem
15、ove the fines by screening through the600 m (No. 30 sieve) and use the pitch retained on this sieveas the test specimen.10. Calibration of Helium Pycnometer10.1 Calibrate daily or before using, following instrumentmanufacturers instructions.11. Procedure11.1 Place 10 to 150 g (80 to 90 % of the maxi
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMD489219892009STANDARDTESTMETHODFORDENSITYOFSOLIDPITCHHELIUMPYCNOMETERMETHOD 固体 硬沥青 密度 标准 试验 方法 比重瓶

链接地址:http://www.mydoc123.com/p-518334.html