ASTM D4541-2017 Standard Test Method for Pull-Off Strength of Coatings Using Portable Adhesion Testers《利用便携式粘性试验机测定涂层拉脱强度的标准试验方法》.pdf
《ASTM D4541-2017 Standard Test Method for Pull-Off Strength of Coatings Using Portable Adhesion Testers《利用便携式粘性试验机测定涂层拉脱强度的标准试验方法》.pdf》由会员分享,可在线阅读,更多相关《ASTM D4541-2017 Standard Test Method for Pull-Off Strength of Coatings Using Portable Adhesion Testers《利用便携式粘性试验机测定涂层拉脱强度的标准试验方法》.pdf(18页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: D4541 17Standard Test Method forPull-Off Strength of Coatings Using Portable AdhesionTesters1This standard is issued under the fixed designation D4541; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the year of last r
2、evision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope*1.1 This test method covers a procedure for evaluating thepull-off strength (commonly referred to as adhesion) of acoating syst
3、em from metal substrates. Pull-off strength ofcoatings from concrete is described in Test Method D7234.This test offers two test protocols. Protocol 1 (test to fracture)determines the greatest perpendicular force (in tension) that asurface area can bear before a plug of material is detached.Protocol
4、 2 (pass/fail) determines if the coated surface remainsintact at a defined load criteria. Fracture will occur along theweakest plane within the system comprised of the test fixture,glue, coating system, and substrate, and will be exposed by thefracture surface. This test method maximizes tensile str
5、ess ascompared to the shear stress applied by other methods, such asscratch or knife adhesion, and results may not be comparable.NOTE 1The procedure in this standard was developed for metalsubstrates, but may be appropriate for other rigid substrates such as plasticand wood. Factors such as loading
6、rate and flexibility of the substrate mustbe addressed by the user/specifier.NOTE 2The procedure in this standard was developed for use on flatsurfaces. Depending on the radius of the surface, the results could havegreater variability with lower values and averages.1.2 Pull-off strength measurements
7、 depend upon material,instrumentation and test parameters. Results obtained by eachtest method may give different results. Results should only beassessed for each test method and not be compared with otherinstruments. There are five instrument types, identified as TestMethods B-F. It is imperative t
8、o identify the test method usedwhen reporting results.NOTE 3Method A, which appeared in previous versions of thisstandard, has been eliminated as its main use is for testing on concretesubstrates (see Test Method D7234).1.3 This test method describes a class of apparatus known asportable pull-off ad
9、hesion testers.2They are capable of apply-ing a concentric load and counter load to a single surface sothat coatings can be tested even though only one side isaccessible. Measurements are limited by the strength of adhe-sive bonds between the loading fixture and the specimensurface or the cohesive s
10、trengths of the glue, coating layers,and substrate.1.4 This test can be destructive and spot repairs may benecessary.1.5 The values stated in either SI units or inch-pound unitsare to be regarded separately as standard. The values stated ineach system may not be exact equivalents; therefore, eachsys
11、tem shall be used independently of the other. Combiningvalues from the two systems may result in non-conformancewith the standard.1.6 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establis
12、h appro-priate safety, health and environmental practices and deter-mine the applicability of regulatory limitations prior to use.1.7 This international standard was developed in accor-dance with internationally recognized principles on standard-ization established in the Decision on Principles for
13、theDevelopment of International Standards, Guides and Recom-mendations issued by the World Trade Organization TechnicalBarriers to Trade (TBT) Committee.2. Referenced Documents2.1 ASTM Standards:3D2651 Guide for Preparation of Metal Surfaces forAdhesiveBondingD3933 Guide for Preparation of Aluminum
14、Surfaces forStructural Adhesives Bonding (Phosphoric Acid Anodiz-ing)D7234 Test Method for Pull-Off Adhesion Strength of Coat-ings on Concrete Using Portable Pull-Off Adhesion Tes-tersE691 Practice for Conducting an Interlaboratory Study toDetermine the Precision of a Test Method1This test method is
15、 under the jurisdiction of ASTM Committee D01 on Paintand Related Coatings, Materials, and Applications and is the direct responsibility ofSubcommittee D01.46 on Industrial Protective Coatings.Current edition approved Aug. 1, 2017. Published September 2017. Originallyapproved in 1993. Last previous
16、edition approved in 2009 as D4541 091. DOI:10.1520/D4541-17.2The term adhesion tester may be somewhat of a misnomer, but its adoption bytwo manufacturers and at least two patents indicates continued usage.3For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer S
17、ervice at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.*A Summary of Changes section appears at the end of this standardCopyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 194
18、28-2959. United StatesThis international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for theDevelopment of International Standards, Guides and Recommendations issued by the World Trade Organization Techn
19、ical Barriers to Trade (TBT) Committee.13. Summary of Test Method3.1 The general pull-off test is performed by securing aloading fixture (dolly, stud) normal (perpendicular) to thesurface of the coating with a glue. After the glue is cured, atesting apparatus is attached to the loading fixture and a
20、lignedto apply tension normal to the test surface. The force applied tothe loading fixture is then gradually and uniformly increasedand monitored until either the loading fixture is detached, or aspecified load value is reached and the test terminated. The twocommon uses of this test are test to fra
21、cture (Protocol 1), andpass/fail testing (Protocol 2). Test to fracture is used todetermine a maximum load that can be achieved when a plugof material is detached with the selected testing parameters.Pass/fail is used to verify the results of a testing procedure canmeet a minimum load criterion. Whe
22、n the loading fixture isdetached, the exposed surface represents the plane of limitingstrength within the system. The nature of the plane of fractureis qualified in accordance with the percent of adhesive andcohesive failures, and the actual interfaces and layers involved.The reported load is comput
23、ed based on the maximum indi-cated load, the instrument calibration data, and the originalsurface area stressed. Results obtained using different testdevices will vary because the results depend on instrumenta-tion parameters. Variations in results are also expected whentests are performed under dif
24、ferent test procedures or environ-mental conditions (see 4.2).4. Significance and Use4.1 The pull-off strength of a coating is a performanceproperty that may be referenced in specifications. This testmethod serves as a means for uniformly preparing and testingcoated surfaces, and evaluating and repo
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMD45412017STANDARDTESTMETHODFORPULLOFFSTRENGTHOFCOATINGSUSINGPORTABLEADHESIONTESTERS 利用 便携式 粘性 试验

链接地址:http://www.mydoc123.com/p-517332.html