ASTM D3977-1997(2013) Standard Test Methods for Determining Sediment Concentration in Water Samples《水样中沉积物浓度的标准试验方法》.pdf
《ASTM D3977-1997(2013) Standard Test Methods for Determining Sediment Concentration in Water Samples《水样中沉积物浓度的标准试验方法》.pdf》由会员分享,可在线阅读,更多相关《ASTM D3977-1997(2013) Standard Test Methods for Determining Sediment Concentration in Water Samples《水样中沉积物浓度的标准试验方法》.pdf(7页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: D3977 97 (Reapproved 2013)Standard Test Methods forDetermining Sediment Concentration in Water Samples1This standard is issued under the fixed designation D3977; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the year
2、 of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope1.1 These test methods cover the determination of sedimentconcentrations in water and wastewater samples collected fro
3、mlakes, reservoirs, ponds, streams, and other water bodies. Inlakes and other quiescent-water bodies, concentrations ofsediment in samples are nearly equal to concentrations atsampling points; in most instances, sample concentrations arenot strongly influenced by collection techniques. In rivers and
4、other flowing-water bodies, concentrations of sediment insamples depend upon the manner in which the samples arecollected. Concentrations in isokinetically-collected samplescan be multiplied by water discharges to obtain sedimentdischarges in the vicinity of the sampling points.1.2 The procedures gi
5、ven in these test methods are used bytheAgricultural Research Service, Geological Survey, NationalResources Conservation Service, Bureau of Reclamation, andother agencies responsible for studying water bodies. Thesetest methods are adapted from a laboratory-procedure manual2and a quality-assurance p
6、lan.31.3 These test methods include:SectionsTest Method AEvaporation 8 to 13Test Method BFiltration 14 to 19Test Method CWet-sieving-filtration 20 to 251.4 Test MethodAcan be used only on sediments that settlewithin the allotted storage time of the samples which usuallyranges from a few days to a fe
7、w weeks. A correction factormust be applied if dissolved-solids concentration exceedsabout 10 % of the sediment concentration.1.5 Test Method B can be used only on samples containingsand concentrations less than about 10 000 ppm and clayconcentrations less than about 200 ppm. The sediment need notbe
8、 settleable because filters are used to separate water from thesediment. Correction factors for dissolved solids are notrequired.1.6 Test Method C can be used if two concentration valuesare required: one for sand-size particles and one for thecombination of silt and clay-size particles. The silt-cla
9、y frac-tion need not be settleable.1.7 These test methods must not be confused with turbiditymeasurements discussed in Test Method D1889. Turbidity isthe optical property of a sample that causes light rays to bescattered and absorbed; it is not an accurate measure of themass or concentration of sedi
10、ment in the sample.1.8 These test methods contain some procedures similar tothose in Test Methods D1888 which pertains to measuringparticulate and dissolved matter in water.1.9 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibili
11、ty of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use.2. Referenced Documents2.1 ASTM Standards:4D1129 Terminology Relating to WaterD1193 Specification for Reagent WaterD1888 Methods OfTest for Pa
12、rticulate and Dissolved Matterin Water (Withdrawn 1989)5D1889 Test Method for Turbidity of Water (Withdrawn2007)5D2777 Practice for Determination of Precision and Bias ofApplicable Test Methods of Committee D19 on WaterD4410 Terminology for Fluvial SedimentD4411 Guide for Sampling Fluvial Sediment i
13、n MotionE11 Specification for Woven Wire Test Sieve Cloth and TestSieves1These test methods are under the jurisdiction of ASTM Committee D19 onWater and are the direct responsibility of Subcommittee D19.07 on Sediments,Geomorphology, and Open-Channel Flow.Current edition approved Jan. 1, 2013. Publi
14、shed January 2013. Originallyapproved in 1980. Last previous edition approved in 2007 as D3977 97 (2007).DOI: 10.1520/D3977-97R13.2Guy, H. P., “Laboratory Theory and Methods for Sediment Analysis,” Tech-niques of Water Resources Investigations , U.S. Geological Survey, Book 5, ChapterC1, 1941.3Matth
15、es,W. J., Jr., Sholar, C., J., and George, J. R.,“ Quality-Assurance Plan forthe Analysis of Fluvial Sediment,” U.S. Geological Survey Open File Report 90,1990.4For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of
16、 ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.5The last approved version of this historical standard is referenced onwww.astm.org.Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States13.
17、Terminology3.1 DefinitionsFor definitions of water-related terms usedin these test methods refer to Terminologies D1129 and D4410.3.2 Definitions of Terms Specific to This Standard:3.2.1 dissolved solidssoluble constituents in water. Thequantity is determined by evaporating a water sample to visible
18、dryness at a temperature slightly below boiling. The tempera-ture is then raised to 105C and held for about 2 h. This isfollowed by cooling in a desiccator and weighing the residue.3.2.2 fluvial sedimentparticles that are (a) derived fromrocks or biological materials and (b) transported by flowingwa
19、ter.3.2.3 sediment concentration(a) the ratio of the mass ofdry sediment in a water-sediment mixture to the mass of themixture or (b) the ratio of the mass of dry sediment in awater-sediment mixture to the volume of the mixture. Asindicated by Table 1, the two ratios differ except at concentra-tions
20、 less than 8000 mg/L.3.2.4 supernateclear, overlying liquid in a sedimentsample.3.2.5 suspended sedimentsediment supported by turbulentcurrents in flowing water or by Brownian movement.3.2.6 tareweights of empty containers used in analysisprocedure.4. Significance and Use4.1 Suspended-sediment sampl
21、es contain particles with awide variety of physical characteristics. By presenting alternateapproaches, these test methods allow latitude in selectinganalysis methods that work best with the particular samplesunder study.4.2 Sediment-concentration data are used for many pur-poses that include: (1) c
22、omputing suspended-sediment dis-charges of streams or sediment yields of watersheds, (2)scheduling treatments of industrial and domestic watersupplies, and (3) estimating discharges of pesticides, plantnutrients, and heavy metals transported on surfaces or insidesediment particles.5. Reagents and Ma
23、terials5.1 Purity of WaterUnless otherwise indicated, referencesto water shall be understood to mean reagent water as definedby Type III of Specification D1193.5.1.1 Requirements can usually be met by passing tap waterthrough a mixed cation-anion exchange resin or by distillation.6. Sampling6.1 Flow
24、s and concentrations in river cross sections areusually unsteady; consequently, in a strict sense, samplesrepresent conditions only at the time and location of samplecollection.6.2 A sample may consist of a single container of awater-sediment mixtures collected at (1) a specific point in ariver cros
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMD397719972013STANDARDTESTMETHODSFORDETERMININGSEDIMENTCONCENTRATIONINWATERSAMPLES 水样 沉积物 浓度 标准 试验

链接地址:http://www.mydoc123.com/p-515952.html