ASTM D3847-2001(2007) Standard Practice for Rubber-Directions for Achieving Subnormal Test Temperatures《橡胶的标准实施规程 获取低于标准的试验温度的导则》.pdf
《ASTM D3847-2001(2007) Standard Practice for Rubber-Directions for Achieving Subnormal Test Temperatures《橡胶的标准实施规程 获取低于标准的试验温度的导则》.pdf》由会员分享,可在线阅读,更多相关《ASTM D3847-2001(2007) Standard Practice for Rubber-Directions for Achieving Subnormal Test Temperatures《橡胶的标准实施规程 获取低于标准的试验温度的导则》.pdf(3页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: D 3847 01 (Reapproved 2007)Standard Practice forRubberDirections for Achieving Subnormal TestTemperatures1This standard is issued under the fixed designation D 3847; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the
2、year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon (e) indicates an editorial change since the last revision or reapproval.1. Scope1.1 This practice covers the general requirements forachieving and maintaining temperatures below 21C for ther-ma
3、l conditioning and physical testing of rubber.1.2 This practice describes the acceptable types and con-struction of low-temperature cabinets for conditioning andtesting of rubber, the composition and circulation of heat-transfer media, and the required uniformity and precision oftemperature control.
4、1.3 The values stated in SI units are to be regarded asstandard. No other units of measurement are included in thisstandard.1.4 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appr
5、o-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use.2. Referenced Documents2.1 ASTM Standards:2D 746 Test Method for Brittleness Temperature of Plasticsand Elastomers by ImpactD 832 Practice for Rubber Conditioning For Low Tempera-ture Testing
6、D 945 Test Methods for Rubber Properties in Compressionor Shear (Mechanical Oscillograph)D 1053 Test Methods for Rubber PropertyStiffening atLow Temperatures: Flexible Polymers and Coated FabricsD 1229 Test Method for Rubber PropertyCompressionSet at Low TemperaturesD 1329 Test Method for Evaluating
7、 Rubber PropertyRetraction at Lower Temperatures (TR Test)D 1415 Test Method for Rubber PropertyInternationalHardnessD 2136 Test Method for Coated FabricsLow-Temperature Bend TestD 2137 Test Methods for Rubber PropertyBrittlenessPoint of Flexible Polymers and Coated FabricsD 2240 Test Method for Rub
8、ber PropertyDurometerHardnessD 2632 Test Method for Rubber PropertyResilience byVertical ReboundE 197 Specification for Enclosures and Servicing Units forTests Above and Below Room Temperature33. Significance and Use3.1 Low temperatures are often needed for conditioning ofrubber prior to testing, as
9、 well as during the test. Conditioningis required to attain a specific temperature that is uniformthroughout the specimen or for producing time-dependenteffects. Specimens may be conditioned and tested in the sameor different chambers.3.2 This practice is intended to apply particularly, but notexclu
10、sively, to the following ASTM Standards: Test MethodsD 746, D 945, D 1053, D 1229, D 1329, D 1415, D 2136,D 2137, D 2240, D 2632, Practice D 832, and SpecificationE 197.4. General Equipment Requirements44.1 The low-temperature cabinet may be refrigerated me-chanically, or by dry ice or liquid nitrog
11、en, either directly orindirectly.4.1.1 The heat-transfer medium in the test chamber shouldbe air or air mixed with carbon dioxide or nitrogen, unless aliquid medium is specified. Although liquids cool the speci-mens faster than gases, they are more likely to cause propertychanges in addition to thos
12、e caused by temperature change.Water, ethyl alcohol, and ethylene glycol are usually acceptablefor immersion times that are kept to the minimum for therequired tests.1This practice is under the jurisdiction ofASTM Committee D11 on Rubber andis the direct responsibility of Subcommittee D11.14 on Time
13、 and Temperature-Dependent Physical Properties.Current edition approved May 1, 2007. Published July 2007. Originally approvedin 1979. Last previous edition approved in 2001 as D 3847 01.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceas
14、tm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.3Withdrawn.4For more detailed information, see Specification E 197.1Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United
15、States.4.1.2 The temperature variation within 250 mm of the testspecimen shall be within 61C of the specified testing tem-perature.4.1.3 The heat-transfer medium should be circulated thor-oughly in the test chamber by means of mechanical agitation.Afan or stirrer suitably located in the test chamber
16、 can be usedfor this purpose.4.1.4 Automatic temperature control should be used.4.2 The size of the test chamber is optional.4.3 The door can be located either in the top of the testcabinet or in the side. A side-opening door is convenient, andis necessary where the equipment involved must be operat
17、edfrom the side. However, it has the disadvantage of allowing thecold air to pour out when the door is opened. In general, awindow in the door is desired for observation and the readingof test equipment indicators. This window should have at leastfive sealed layers of glass, suitably spaced, with de
18、hydrated airbetween the layers to prevent condensation or frosting.4.3.1 Return to the test temperature after the introduction ofspecimens or test apparatus should be as rapid as possibleconsistent with minimal overshoot, but should not exceed 15min. Particular care is required for gaseous media.4.3
19、.2 When the measuring device cannot be located logi-cally within the low-temperature chamber, it should have anextension rod of low thermal conductivity that extends throughthe insulated wall and contacts the specimen. An example isgiven in Test Methods D 1053.4.4 Chambers used for conditioning of s
20、pecimens prior tothe test should provide adequate circulation on all sides of thespecimens. Suitable supports include racks, metal clips, andwide-mesh wirescreen frames with at least 25 mm between thescreen and the cabinet floor. For chambers that are in continu-ous use, chamber walls having a maxim
21、um heat transmissionfactor of 35 mW/mK (0.24 Btuin./hft2F) are desirable. Forthe operation of the equipment involved in Test MethodsD 2240 and D 2632, handholes equipped with gloves andinsulated sleeves should be installed in the walls of the testcabinet. The interior walls surrounding the chamber s
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便