ASTM D3578-2005(2015) Standard Specification for Rubber Examination Gloves《检查用橡胶手套的标准规格》.pdf
《ASTM D3578-2005(2015) Standard Specification for Rubber Examination Gloves《检查用橡胶手套的标准规格》.pdf》由会员分享,可在线阅读,更多相关《ASTM D3578-2005(2015) Standard Specification for Rubber Examination Gloves《检查用橡胶手套的标准规格》.pdf(5页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: D3578 05 (Reapproved 2015)Standard Specification forRubber Examination Gloves1This standard is issued under the fixed designation D3578; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the year of last revision. A numb
2、er in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.This standard has been approved for use by agencies of the U.S. Department of Defense.1. Scope1.1 This specification covers certain requirements for na
3、tu-ral rubber gloves used in conducting medical examinations anddiagnostic and therapeutic procedures. It also covers naturalrubber gloves used in handling contaminated medical material.1.2 This specification provides for natural rubber gloves thatfit either hand, paired gloves, and gloves by size.
4、It alsoprovides for packaged sterile natural rubber gloves and pack-aged or bulk nonsterile natural rubber gloves.2. Referenced Documents2.1 ASTM Standards:2D412 Test Methods for Vulcanized Rubber and Thermoplas-tic ElastomersTensionD573 Test Method for RubberDeterioration in an AirOvenD3767 Practic
5、e for RubberMeasurement of DimensionsD5151 Test Method for Detection of Holes in MedicalGlovesD5712 Test Method for Analysis of Aqueous ExtractableProtein in Latex, Natural Rubber, and Elastomeric Prod-ucts Using the Modified Lowry MethodD6124 Test Method for Residual Powder on Medical GlovesD6499 T
6、est Method for The Immunological Measurement ofAntigenic Protein in Natural Rubber and its Products2.2 Other Documents:ISO 2859 Sampling Procedures and Tables for Inspection byAttributes3U. S. Pharmacopeia43. Classification3.1 Type IGloves with a minimum tensile strength of 18MPa and a maximum stres
7、s at 500 % elongation of 5.5 MPa.3.2 Type IIGloves with a minimum tensile strength of 14MPa and a maximum stress at 500 % elongation of 2.8 MPa.4. Materials and Manufacture4.1 Any natural rubber compound that permits the glove tomeet the requirements of this specification.4.2 A lubricant that meets
8、the current requirements of theU.S. Pharmacopeia for Absorbable Dusting Powder may beapplied to the glove. Other lubricants may be used if theirsafety and efficacy have been previously established.4.3 The inside and outside surface of the natural rubberexamination gloves shall be free of talc.5. Sig
9、nificance and Use5.1 The specification is intended as a reference to theperformance and safety of natural rubber examination gloves.The safe and proper use of natural rubber examination glovesis beyond the scope of this specification.6. Sampling6.1 For referee purposes, gloves shall be sampled andin
10、spected in accordance with ISO 2859. The inspection levelsand acceptable quality levels (AQL) shall conform to thosespecified in Table 1, or as agreed between the purchaser and theseller, if the latter is more comprehensive.7. Performance Requirements7.1 Gloves, sampled in accordance with Section 6,
11、 shallmeet the following referee performance requirements:7.1.1 Comply with requirements for sterility when tested inaccordance with 8.2.7.1.2 Be free from holes when tested in accordance with 8.3.7.1.3 Have consistent physical dimensions in accordancewith 8.4.7.1.4 Have acceptable physical property
12、 characteristics inaccordance with 8.5.7.1.5 Have a powder residue limit of 2.0 mg in accordancewith 8.6.1This specification is under the jurisdiction ofASTM Committee D11 on Rubberand is the direct responsibility of Subcommittee D11.40 on Consumer RubberProducts.Current edition approved Nov. 1, 201
13、5. Published December 2015. Originallyapproved in 1977. Last previous edition approved in 2010 as D3578 05(2010).DOI: 10.1520/D3578-05R15.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume
14、information, refer to the standards Document Summary page onthe ASTM website.3Available from American National Standards Institute (ANSI), 25 W. 43rd St.,4th Floor, New York, NY 10036.4U.S. Pharmacopeia, latest edition, Mack Publishing Co., Easton, PA, 19175.Copyright ASTM International, 100 Barr Ha
15、rbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States17.1.6 Have a recommended aqueous soluble protein contentlimit of 200 g/dm2in accordance with 8.7 and Annex A1 orhave a recommended antigenic protein content limit of 10g/dm2in accordance with 8.9 and Annex A2.7.1.7 Have a recom
16、mended maximum powder limit of 10mg/dm2in accordance with 8.8.8. Referee Test Methods8.1 The following tests shall be conducted to ensure therequirements of Section 8, as prescribed in Table 1:8.2 Sterility TestTesting for sterility shall be conducted inaccordance with the latest edition of The U.S.
17、 Pharmacopeia.8.3 Freedom From HolesTesting for freedom from holesshall be conducted in accordance with Test Method D5151.8.4 Physical Dimensions Test (Practice D3767):8.4.1 The gloves shall comply with the dimension require-ments prescribed in Table 2.8.4.2 The length shall be expressed in millimet
18、res as mea-sured from the tip of the middle finger to the outside edge ofthe cuff as indicated in Fig. 1.8.4.3 The width of the palm shall be expressed in millime-tres as measured at a level between the base of the index fingerand the base of the thumb. Values of width per size other thanlisted shal
19、l meet the stated tolerance specified in Table 2.8.4.4 The minimum thickness shall be expressed in milli-metres as specified in Table 2 when using a dial micrometerdescribed in Test Methods D412 and in the locations indicatedon Fig. 1. For referee tests, cutting the glove is necessary toobtain singl
20、e-thickness measurements.8.5 Physical Requirements Test:8.5.1 Before and after accelerated aging, the gloves shallconform to the physical requirements specified in Table 3.Tests shall be conducted as specified in Test Methods D412.Die C is recommended.8.5.2 Accelerated aging tests shall be conducted
21、 in accor-dance with Test Method D573. Test the gloves by either one ofthe following methods:8.5.2.1 After being subjected to a temperature of 70 6 2Cfor 166 6 2 h, the tensile strength and ultimate elongation shallnot be less than the values specified in Table 3. This methodshall be the condition f
22、or referee tests.8.5.2.2 After being subjected to a temperature of 100 6 2Cfor 22 6 0.3 h, the tensile strength and ultimate elongationshall not be less than the values specified in Table 3.8.6 Powder Free Gloves:8.6.1 Determine the powder residue using Test MethodD6124.8.7 Aqueous Extractable Prote
23、in Content:8.7.1 Determine the aqueous extractable protein (g/mL)using Test Method D5712 for each glove sample tested.8.7.2 Determine the total micrograms of aqueous extract-able protein in each glove sample by multiplying the resultfrom 8.7.1 by the total volume of extractant used for thatspecific
24、glove sample. If the glove sample is less than a wholeglove, then adjust the protein results to reflect the amount ofprotein in the whole glove.8.7.3 Determine the square decimeters for the glove size.Multiply the minimum length and nominal width found inTable 2 and convert to dm2using (dm2/mm2) (mm
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMD357820052015STANDARDSPECIFICATIONFORRUBBEREXAMINATIONGLOVES 检查 橡胶 手套 标准 规格 PDF

链接地址:http://www.mydoc123.com/p-515042.html