ASTM D3418-2008 Standard Test Method for Transition Temperatures and Enthalpies of Fusion and Crystallization of Polymers by Differential Scanning Calorimetry《用差示扫描量热法测定聚合物转变温度的标准试.pdf
《ASTM D3418-2008 Standard Test Method for Transition Temperatures and Enthalpies of Fusion and Crystallization of Polymers by Differential Scanning Calorimetry《用差示扫描量热法测定聚合物转变温度的标准试.pdf》由会员分享,可在线阅读,更多相关《ASTM D3418-2008 Standard Test Method for Transition Temperatures and Enthalpies of Fusion and Crystallization of Polymers by Differential Scanning Calorimetry《用差示扫描量热法测定聚合物转变温度的标准试.pdf(7页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: D 3418 08Standard Test Method forTransition Temperatures and Enthalpies of Fusion andCrystallization of Polymers by Differential ScanningCalorimetry1This standard is issued under the fixed designation D 3418; the number immediately following the designation indicates the year oforiginal
2、 adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.This standard has been approved for use by agencies of the Department of Defens
3、e.1. Scope*1.1 This test method covers determination of transitiontemperatures and enthalpies of fusion and crystallization ofpolymers by differential scanning calorimetry.NOTE 1True heats of fusion are to be determined in conjunction withstructure investigation, and frequently, specialized crystall
4、ization tech-niques are needed.1.2 This test method is applicable to polymers in granularform or to any fabricated shape from which it is possible to cutappropriate specimens.1.3 The normal operating temperature range is from thecryogenic region to 600C. Certain equipment allows thetemperature range
5、 to be extended.1.4 The values stated in SI units are the standard.NOTE 2This test method does not apply to all types of polymers aswritten (see 6.8).1.5 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this
6、standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use.NOTE 3This standard is similar but not equivalent to ISO 11357-1, -2,-3. The ISO procedures provide additional information not supplied bythis test method.2. Referen
7、ced Documents2.1 ASTM Standards:2E 473 Terminology Relating to Thermal Analysis and Rhe-ologyE 691 Practice for Conducting an Interlaboratory Study toDetermine the Precision of a Test MethodE 967 Test Method for Temperature Calibration of Differ-ential Scanning Calorimeters and Differential ThermalA
8、nalyzersE 968 Practice for Heat Flow Calibration of DifferentialScanning CalorimetersE 1142 Terminology Relating to Thermophysical PropertiesE 1953 Practice for Description of Thermal Analysis andRheology Apparatus2.2 ISO Standards:3ISO 11357-1 PlasticsDifferential Scanning Calorimetry(DSC)Part 1: G
9、eneral PrinciplesISO 11357-2 PlasticsDifferential Scanning Calorimetry(DSC)Part 2: Determination of Glass Transition Tem-peratureISO 11357-3 PlasticsDifferential Scanning Calorimetry(DSC)Part 3: Determination of Temperature and En-thalpy of Melting and Crystallization3. Terminology3.1 Specialized te
10、rms used in this test method are defined inTerminologies E 473 and E 1142.4. Summary of Test Method4.1 This test method consists of heating or cooling the testmaterial at a controlled rate under a specified purge gas at acontrolled flow rate and continuously monitoring with asuitable sensing device
11、the difference in heat input between areference material and a test material due to energy changes inthe material. A transition is marked by absorption or release ofenergy by the specimen resulting in a corresponding endother-mic or exothermic peak or baseline shift in the heating orcooling curve. A
12、reas under the crystallization exotherm orfusion endotherm of the test materials are compared against the1This test method is under the jurisdiction of ASTM Committee D20 on Plasticsand is the direct responsibility of Subcommittee D20.30 on Thermal Properties(Section D20.30.07).Current edition appro
13、ved Nov. 1, 2008. Published December 2008. Originallyapproved in 1975. Last previous edition approved in 2003 as D 3418 - 03.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information,
14、refer to the standards Document Summary page onthe ASTM website.3Available from American National Standards Institute (ANSI), 25 W. 43rd St.,4th Floor, New York, NY 10036, http:/www.ansi.org.1*A Summary of Changes section appears at the end of this standard.Copyright ASTM International, 100 Barr Har
15、bor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.respective areas obtained by the treatment of a well-characterized standard.5. Significance and Use5.1 Thermal analysis provides a rapid method for measuringtransitions due to morphological or chemical changes, in apolymer as it
16、 is heated/cooled through a specified temperaturerange. Change in specific heat capacity, heat flow and tempera-ture values are determined for these transitions. Differentialscanning calorimetry is used to assist in identifying specificpolymers, polymer alloys, and certain polymer additives,which ex
17、hibit thermal transitions. Chemical reactions thatcause or affect certain transitions have been measured with theaid of this technique; such reactions include oxidation, curingof thermosetting resins, and thermal decomposition.5.2 This test method is useful for specification acceptance,process contr
18、ol, and research.6. Interferences6.1 Differences in heating or cooling rate as well as the finalheating and cooling temperature have an effect on the mea-sured results, especially on the enthalpy of fusion or crystalli-zation. Therefore, departure from conditions specified for agiven polymer is not
19、permitted.6.2 The presence of impurities is known to affect thetransition temperature, particularly if an impurity tends to formsolid solutions, or to be miscible in the melt phase.6.3 Uncertain radiation losses at temperatures higher than400C have been known to affect the accuracy of results attime
20、s.6.4 Since particle size has an effect upon detected transitiontemperatures, the specimens to be compared shall be approxi-mately the same particle size (1-5).46.5 In cases that specimens react with air during thetemperature cycle, provision shall be made for running the testunder an inert gas blan
21、ket to avoid any incorrect measurement.Since some materials degrade near the melting region, caremust be used to distinguish between degradation and transition.6.6 Since milligram quantities of a specimen are used, it isessential to ensure that specimens are homogeneous andrepresentative.6.7 It is p
22、ossible that toxic or corrosive effluents are releasedwhen heating the material, and be harmful to the personnel orto the apparatus.6.8 Not all polymers lend themselves to the exact terms ofthis test method. For some polymers such as polyarylamides,crystallization is only possible from solution. For
23、 other poly-mers such as crystallizable polystyrene, annealing is onlypossible above their glass transition temperatures. When thistest method is used for polymers of this type, carefullyannealed samples must be tested without conditioning.7. Apparatus7.1 Differential Scanning Calorimeter (DSC)The e
24、ssen-tial instrumentation required to provide the minimum differen-tial scanning calorimetric capability for this test methodincludes:7.1.1 DSC Test ChamberThis chamber is composed of thefollowing:7.1.1.1 Furnace(s), to provide uniform controlled heating(cooling) of a specimen and reference to a con
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMD34182008STANDARDTESTMETHODFORTRANSITIONTEMPERATURESANDENTHALPIESOFFUSIONANDCRYSTALLIZATIONOFPOLYMERSBYDIFFERENTIALSCANNINGCALORIMETRY

链接地址:http://www.mydoc123.com/p-514742.html