ASTM D3342-1990(2006) Standard Test Method for Dispersion Stability of New (Unused) Rolling Oil Dispersions in Water《新(未经使用的)辊压油在水中分散稳定性的标准试验方法》.pdf
《ASTM D3342-1990(2006) Standard Test Method for Dispersion Stability of New (Unused) Rolling Oil Dispersions in Water《新(未经使用的)辊压油在水中分散稳定性的标准试验方法》.pdf》由会员分享,可在线阅读,更多相关《ASTM D3342-1990(2006) Standard Test Method for Dispersion Stability of New (Unused) Rolling Oil Dispersions in Water《新(未经使用的)辊压油在水中分散稳定性的标准试验方法》.pdf(4页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: D 3342 90 (Reapproved 2006)An American National StandardStandard Test Method forDispersion Stability of New (Unused) Rolling OilDispersions in Water1This standard is issued under the fixed designation D 3342; the number immediately following the designation indicates the year oforiginal
2、 adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon (e) indicates an editorial change since the last revision or reapproval.1. Scope1.1 This test method covers determination of the dispersionstability o
3、f dispersions of rolling oils in water. It is applicableto oils whose water dispersions are stable under moderateagitation, but which show at least some separation uponstanding quiescent for12 h, by rising of the oil particles.1.2 The values stated in SI units are to be regarded asstandard. No other
4、 units of measurement are included in thisstandard.1.3 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of
5、regulatory limitations prior to use. For specific hazardstatements, see 6.2, A2.1, and A2.5.2. Referenced Documents2.1 ASTM Standards:2D 1126 Test Method for Hardness in WaterD 1293 Test Methods for pH of Water3. Summary of Test Method3.1 The rolling oil is dispersed in a standard test water, in ast
6、andard container, under standard conditions of time, agita-tion, and concentration. When the agitation is stopped, theresulting decrease in oil concentration at a specified point nearthe bottom of the container is measured at certain time intervalsand plotted.4. Significance and Use4.1 Each steel ro
7、lling mill and operation is particular as tothe degree of stability of dispersion required to effect maxi-mum efficiency of lubrication and cooling. This test method isdesigned to differentiate between coolants for this use. Asimilar situation is encountered with aluminum rolling mills,but significa
8、nt differences in designated settling times berequired outside the parameter of times used herein. Precisiondata have only been obtained relative to metastable dispersionsfor steel mill rolling oils.5. Apparatus5.1 Mixing Beaker,3,45800 mL capacity, made of stainlesssteel, modified as shown in Annex
9、 A2.5.2 Combination Agitator and Temperature Control De-vice.4,55.3 Babcock Centrifuge Bottles4,6The 165-mm cream testbottle, with 5 mL-neck permitting oil concentration readingsfrom 0 to 10 % is preferred. These bottles should be marked forfilling to the 50-mL level which will normally be found clo
10、seto the junction of body and neck. Sulfonation bottles may alsobe used.5.4 Centrifuge, capable of whirling the Babcock bottles atsufficient speed to give a clean separation of oil and waterunder the test conditions. A centrifuge giving a relativecentrifugal force (rcf) of 5009 at the bottle tips ha
11、s been foundto give good separations in 10 min.5.5 To calculate the rpm required to achieve the stated rcf,use the following formula:rpm 5 1335=rcf/d (1)where:rcf = relative centrifugal force,d = diameter of swing measured between tips of oppo-site tubes when in rotating position, mm, andrpm = revol
12、utions per minute.1This test method is under the jurisdiction of ASTM Committee D02 onPetroleum Products and Lubricants and is the direct responsibility of SubcommitteeD02.L0 on Industrial Lubricants.Current edition approved July 1, 2006. Published August 2006. Originallyapproved in 1990. Last previ
13、ous edition approved in 2000 as D 334290 (2000)e1.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.3The sole s
14、ource of supply of the apparatus (beaker #2-584F) known to thecommittee at this time is Fisher Scientific.4If you are aware of alternative suppliers, please provide this information toASTM International Headquarters. Your comments will receive careful consider-ation at a meeting of the responsible t
15、echnical committee,1which you may attend.5The sole source of supply of the apparatus (the Porta-temp) known to thecommittee at this time is Precision Scientific Co.6The sole source of supply of the apparatus (cream test bottle No. 12-705 orsulfonation bottle No. 6-904) known to the committee at this
16、 time is FisherScientific.1Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.5.6 Stop Watch, or similar timing device.6. Reagents6.1 Buffered Synthetic Hard Water, prepared in accordancewith Annex A2.6.2 Sulfuric Acid, 30 vol % in water
17、. Lower acid concen-trations may be used if clean separations are obtained.(WarningSulfuric acid is poison, corrosive, and a strongoxidizer.)7. Procedure7.1 The flow rate of the combination agitator and tempera-ture control device should be between 3500 and 4500 mL/min.The flow rate should be measur
18、ed with a piece of 6.35-mminside diameter bore plastic tubing temporarily attached to thepump outlet and removed after this measurement. During thetest, do not use attachments such as tubing, stopcocks, pinchclamps, etc. on the pump outlet.7.2 Add 4275 mL of test water to the beaker, install theagit
19、ator-temperature control device, and adjust it for 60Ctemperature. When the water reaches this temperature, add225 mL of the rolling oil to be tested. (The oil sample shouldbe sufficiently agitated to assure complete mixing of oilcomponents. With most materials, sufficient heat to melt all ofthe com
20、ponents will also be required, however, at no timeshould the temperature exceed 60C.) Continue controlledtemperature agitation for 30 min.7.3 While agitation continues, fill one Babcock bottle for anemulsion concentration control test, as follows: Open the pinchclamp on the beaker sample tap for 2 t
21、o 3 s. Discard about20 mL of emulsion to flush the tap, and attempt to come ascleanly as possible to the end. Close the pinch clamp, place thehose tip in a Babcock bottle, and fill it at a rapid flow rate to the50-mL mark.7.4 Stop agitation and re-start the stop watch at zero time.Fill Babcock bottl
22、es as described above at 30 s and 1, 2, 4, 8,16, and 32 min elapsed time. It is permissable to stop samplingsooner or later (such as at 16 or 64 min) if such data aredesired, but earlier sample times may not be omitted even forvery stable emulsions, because the sampling process slightlyaffects furth
23、er settling rates. For each sample, purge the sampletap several seconds ahead of time so that filling the Babcockbottle starts at the correct time.7.5 Fill each Babcock bottle to the upper graduation linewith 30 vol% sulfuric acid. Swirl while filling. Spin in thecentrifuge for 10 min, or until a cl
24、ean separation is obtained. Itmay be necessary to use a different mineral acid or to heat thefilled Babcock bottles to facilitate a clean separation. (Ifhowever, none of these methods results in a clean separation,the test method cannot be considered applicable for thatparticular oil.) Read the diff
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMD334219902006STANDARDTESTMETHODFORDISPERSIONSTABILITYOFNEWUNUSEDROLLINGOILDISPERSIONSINWATER 未经 使用

链接地址:http://www.mydoc123.com/p-514605.html