ASTM D3161-2008 Standard Test Method for Wind-Resistance of Asphalt Shingles (Fan-Induced Method).pdf
《ASTM D3161-2008 Standard Test Method for Wind-Resistance of Asphalt Shingles (Fan-Induced Method).pdf》由会员分享,可在线阅读,更多相关《ASTM D3161-2008 Standard Test Method for Wind-Resistance of Asphalt Shingles (Fan-Induced Method).pdf(3页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: D 3161 08Standard Test Method forWind-Resistance of Asphalt Shingles (Fan-Induced Method)1This standard is issued under the fixed designation D 3161; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the year of last rev
2、ision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon (e) indicates an editorial change since the last revision or reapproval.This standard has been approved for use by agencies of the Department of Defense.1. Scope1.1 This test method covers the procedure for te
3、sting thewind resistance of asphalt shingles when applied to a test deckon low slopes in accordance with the manufacturers instruc-tions at the most susceptible slope for wind damage of 2:12(17 %) permitted by those instructions. It is used to benchmarkthe blow-off resistance of sealed and interlock
4、ed shingles at agiven wind velocity, but may be used to test unsealed or sealedshingles at other wind velocities as is applicable.1.2 The values stated in SI units are to be regarded as thestandard. The values given in parentheses are for informationonly.1.3 This standard does not purport to address
5、 all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use.2. Referenced Documents2.1 ASTM Standards:2D 1079 Terminolog
6、y Relating to Roofing and Waterproof-ing3. Terminology3.1 DefinitionsFor definitions of terms used in this testmethod, refer to Terminology D 1079.4. Type and Classes of Shingles4.1 Shingles are of two types:4.1.1 Type IShingles with a factory-applied adhesive(self-sealing shingles).4.1.2 Type IIShi
7、ngles of the lock type, with mechanicallyinterlocking tabs or ears.4.2 Shingles are of three classes:4.2.1 Class APass at a test velocity of 97 km/h (60 mph).4.2.2 Class DPass at a test velocity of 145 km/h (90mph).4.2.3 Class FPass at a test velocity of 177 km/h (110mph).5. Significance and Use5.1
8、Most asphalt shingles that have demonstrated windresistance by this test have also performed well in use. Naturalwind conditions differ with respect to intensity, duration, andturbulence; these conditions are beyond the means of this testto simulate. The results of this test do not directly correlat
9、e towind speeds experienced in service, and no accommodation ismade in this test method for building height, building exposurecategory, or building importance factor.5.2 Many factors influence the sealing characteristics ofshingles in the field; for example, temperature, time, roof slope,contaminati
10、on by dirt and debris, and fasteners that aremisaligned or under-driven and interfere with sealing. It isbeyond the scope of this test method to address all of theseinfluences. When testing shingles with sealant, this test methodis designed to determine the wind resistance when representa-tive sampl
11、es of shingles are sealed under defined conditionsbefore testing.6. Apparatus6.1 Test Machine, capable of delivering a horizontal streamof air through a rectangular opening 914 mm (36 in.) wide and305 mm (12 in.) high at a velocity not less than 97 km/h (60mph). At a velocity of not less than 177 km
12、/h (110 mph), it ispermissible to add a duct section to the equipment to lower theheight of the rectangular opening to 152 mm (6 in.). The testvelocity shall not vary more than 65 mph as measured at aminimum of three evenly spaced locations across the orifice.1This test method is under the jurisdict
13、ion of ASTM Committee D08 on Roofingand Waterproofing and is the direct responsibility of Subcommittee D08.02 onPrepared Roofings, Shingles and Siding Materials.Current edition approved Jan. 15, 2008. Published March 2008. Originallyapproved in 1972. Last previous edition approved in 2006 as D 3161
14、06.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.1Copyright ASTM International, 100 Barr Harbor Drive, PO B
15、ox C700, West Conshohocken, PA 19428-2959, United States.The machine shall be equipped with an adjustable stand toreceive a test panel and be adapted to setting the test panel atany desired slope, at any horizontal distance from the loweredge of the duct opening, and at various angles incident to th
16、ewind direction.6.2 Timer, capable of reading to the nearest minute.6.3 Mechanical Circulation Conditioning Cell or Room, forself-sealing shingles, having forced circulation of air capableof receiving a 1.27-m (50-in.) wide by 1.68-m (66-in.) long, orlarger test panel on a slope of 2:12 (17 %) and o
17、f maintaininga uniform temperature of 57 to 60C (135 to 140F).7. Test Samples7.1 The test panels shall be of plywood, tightly matchedsheathing boards, or other suitable decking material and notless than 1.27 by 1.68 m (50 by 66 in.) in size. They are to beof such rigidity that they will not twist or
18、 distort with normalhandling, or vibrate from the wind velocity during the test.7.2 Apply self-sealing shingles to duplicate panels, parallelto the short dimension of the panel, in the normal mannerrecommended by the manufacturer. Use roofing nails, properlypositioned in accordance with the manufact
19、urers instructions,to fasten each shingle, and no cement other than the factory-applied adhesive shall be used to fasten down the tabs. Do notapply pressure to the shingle tabs either during or afterapplication.7.3 Apply lock-type shingles to at least four panels, parallelto the short dimension of t
20、he panel, in accordance with themanufacturers instructions. Secure the shingles at the outeredge of the test panel by exposed nailing to simulate anchoringat the rake edges of a roof deck.7.4 Control the temperature at 27 6 8C (80 6 15F) andmaintain the slope of the panel at 2:12 (17 %) during appli
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMD31612008STANDARDTESTMETHODFORWINDRESISTANCEOFASPHALTSHINGLESFANINDUCEDMETHODPDF

链接地址:http://www.mydoc123.com/p-514187.html