ASTM D2532-2010 Standard Test Method for Viscosity and Viscosity Change After Standing at Low Temperature of Aircraft Turbine Lubricants《航空涡轮发动机用润滑剂在低温条件下的粘度和粘度变化的标准试验方法》.pdf
《ASTM D2532-2010 Standard Test Method for Viscosity and Viscosity Change After Standing at Low Temperature of Aircraft Turbine Lubricants《航空涡轮发动机用润滑剂在低温条件下的粘度和粘度变化的标准试验方法》.pdf》由会员分享,可在线阅读,更多相关《ASTM D2532-2010 Standard Test Method for Viscosity and Viscosity Change After Standing at Low Temperature of Aircraft Turbine Lubricants《航空涡轮发动机用润滑剂在低温条件下的粘度和粘度变化的标准试验方法》.pdf(4页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: D2532 10Standard Test Method forViscosity and Viscosity Change After Standing at LowTemperature of Aircraft Turbine Lubricants1This standard is issued under the fixed designation D2532; the number immediately following the designation indicates the year oforiginal adoption or, in the ca
2、se of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.This standard has been approved for use by agencies of the Department of Defense.1. Scope*1.1 This tes
3、t method covers the determination of the kine-matic viscosity of aircraft turbine lubricants at low tempera-ture, and the percent change of viscosity after a 3-h and a 72-hstanding period at low temperature.1.2 The values stated in SI units are to be regarded asstandard. No other units of measuremen
4、t are included in thisstandard.1.2.1 The SI units for Kinematic Viscosity are mm2/s. Foruser reference, 1 mm2/s=10-6m2/s = 1 cSt.1.3 WARNINGMercury has been designated by manyregulatory agencies as a hazardous material that can causecentral nervous system, kidney and liver damage. Mercury, orits vap
5、or, may be hazardous to health and corrosive tomaterials. Caution should be taken when handling mercury andmercury containing products. See the applicable product Ma-terial Safety Data Sheet (MSDS) for details and EPAswebsitehttp:/www.epa.gov/mercury/faq.htmfor addi-tional information. Users should
6、be aware that selling mercuryand/or mercury containing products into your state or countrymay be prohibited by law.1.4 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate
7、safety and health practices and determine the applica-bility of regulatory limitations prior to use. For specific hazardstatements, see Section 6.2. Referenced Documents2.1 ASTM Standards:2D445 Test Method for Kinematic Viscosity of Transparentand Opaque Liquids (and Calculation of Dynamic Viscos-it
8、y)E1 Specification for ASTM Liquid-in-Glass Thermometers3. Summary of Test Method3.1 Kinematic viscosity is measured at low temperature inaccordance with Test Method D445 and at time intervals of 3 hand 72 h.NOTE 1This test method was developed and the precision establishedon tests at 53.9C (65F). I
9、t is also applied at 40C (40F) and maybe used at other temperatures. Viscosities may be measured and reportedat other intervals as agreed by the contracting parties.4. Significance and Use4.1 Aircraft turbine lubricants, upon standing at low tem-peratures for prolonged periods of time, may show an i
10、ncreasein kinematic viscosity. This increase may cause lubricationproblems in aircraft engines. Thus, this test method is used toensure that the kinematic viscosity does not exceed themaximum kinematic viscosity in certain specifications foraircraft turbine lubricants.5. Apparatus5.1 Viscometers, dr
11、ying tubes, low-temperature bath, ther-mometer, timer, secondary viscosity standard, filter, and clean-ing supplies are described in detail in Test Method D445.5.2 ViscometerThe viscometer shall meet the require-ments of Test Method D445 and be of the type in which thesample can be rerun without cle
12、aning the viscometer. Suitableholders should be used. For convenience it is recommendedthat the viscometer size be chosen to keep the efflux timebetween 200 and 1000 s.5.3 Drying TubesFit the viscometer openings with dryingtubes filled with indicating silica gel, using cotton at top andbottom to hol
13、d the loosely packed desiccant in place. Providea cross-connection on the viscometer side of the drying tubes(which can be closed by a pinch clamp or stopcock while liquidis being drawn into the efflux bulb) so that the restriction to air1This test method is under the jurisdiction of ASTM Committee
14、D02 onPetroleum Products and Lubricants and is the direct responsibility of SubcommitteeD02.07 on Flow Properties.Current edition approved July 1, 2010. Published July 2010. Originally approvedin 1966. Last previous edition approved in 2003 as D253203. DOI: 10.1520/D2532-10.2For referenced ASTM stan
15、dards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.1*A Summary of Changes section appears at the end of this standard.Copyright ASTM Inte
16、rnational, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.flow will not cause error. Replace the silica gel when alavender color is noticeable.5.4 Viscosity Temperature BathThe constant-temperaturebath must be capable of holding several viscometers at once. Itmus
17、t have adequate stirring of the liquid medium (Note 2) andbalance between heat losses such that the bath temperature canbe maintained at the required temperature 60.03C (60.05F).NOTE 2Isopropanol or other clear, low-freezing liquid may be used asa bath liquid.5.5 Low-Temperature Storage CabinetIf it
18、 is desired toexercise the option described in Note 3 (7.4), a low-temperature storage cabinet or bath shall be provided which iscapable of holding the required temperature with a variationnot to exceed 60.3C (60.5F).5.6 Bath ThermometerCalibrated ASTM Kinematic Vis-cosity Test Thermometer such as 7
19、3F or 74F conforming to therequirements as prescribed in Specification E1. Other cali-brated thermometric devices are permissible provided theiraccuracy, precision, and sensitivity are equal to or better thanthe above thermometers.5.7 Secondary Viscosity Standards.36. Procedure for Cleaning Viscomet
20、ers and Filter Screen6.1 Apply air pressure or suction to the viscometer toremove any previous test specimen. Allow the viscometer todrain for 5 min.6.1.1 Wash the viscometer four times, inside and out, withfresh toluene (WarningFlammable) using suction as re-quired. Allow the viscometer to drain.6.
21、1.2 Wash the viscometer four times, inside and out, withacetone, and allow to drain for 5 min. Then dry with suction.6.1.3 Clean the viscometer thoroughly by filling it com-pletely with glass cleaning solution. Allow to drain for 5 min.6.1.4 Rinse viscometer inside and out with distilled wateruntil
22、all traces of the cleaning solution are completely re-moved. Allow to drain for 5 min.6.1.5 Dry in oven at approximately 100C (212F).6.2 Clean the filter screen by first disassembling the screen(if practicable).6.2.1 Rinse thoroughly with fresh toluene (WarningFlammable).6.2.2 Rinse thoroughly with
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMD25322010STANDARDTESTMETHODFORVISCOSITYANDVISCOSITYCHANGEAFTERSTANDINGATLOWTEMPERATUREOFAIRCRAFTTURBINELUBRICANTS

链接地址:http://www.mydoc123.com/p-513048.html