ASTM D2532-2003 Standard Test Method for Viscosity and Viscosity Change After Standing at Low Temperature of Aircraft Turbine Lubricants《航空汽轮机润滑剂承受低温后粘度和粘度变化的标准测试方法》.pdf
《ASTM D2532-2003 Standard Test Method for Viscosity and Viscosity Change After Standing at Low Temperature of Aircraft Turbine Lubricants《航空汽轮机润滑剂承受低温后粘度和粘度变化的标准测试方法》.pdf》由会员分享,可在线阅读,更多相关《ASTM D2532-2003 Standard Test Method for Viscosity and Viscosity Change After Standing at Low Temperature of Aircraft Turbine Lubricants《航空汽轮机润滑剂承受低温后粘度和粘度变化的标准测试方法》.pdf(3页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: D 2532 03An American National StandardStandard Test Method forViscosity and Viscosity Change After Standing at LowTemperature of Aircraft Turbine Lubricants1This standard is issued under the fixed designation D 2532; the number immediately following the designation indicates the year of
2、original adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon (e) indicates an editorial change since the last revision or reapproval.This standard has been approved for use by agencies of the Department
3、of Defense.1. Scope*1.1 This test method covers the determination of the kine-matic viscosity of aircraft turbine lubricants at low tempera-ture, and the percent change of viscosity after a 3-h and a 72-hstanding period at low temperature.1.2 This test method uses the millimetre squared per second(m
4、m2/s) as the unit of kinematic viscosity. For information, theequivalent cgs unit, the centistokes, is shown in parentheses.1.3 The values stated in SI units are to be regarded as thestandard. The values given in parentheses are for informationonly.1.4 This standard does not purport to address all o
5、f thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use. For specific hazardstatements, see Section 6.2. Referenced Docume
6、nts2.1 ASTM Standards:2D 445 Test Method for Kinematic Viscosity of Transparentand Opaque Liquids (the Calculation of Dynamic Viscos-ity)E1 Specification for ASTM Thermometers3. Summary of Test Method3.1 Kinematic viscosity is measured at low temperature inaccordance with Test Method D 445 and at ti
7、me intervals of 3 hand 72 h.NOTE 1This test method was developed and the precision establishedon tests at 53.9C (65F). It is also applied at 40C (40F) and maybe used at other temperatures. Viscosities may be measured and reportedat other intervals as agreed by the contracting parties.4. Significance
8、 and Use4.1 Aircraft turbine lubricants, upon standing at low tem-peratures for prolonged periods of time, may show an increasein kinematic viscosity. This increase may cause lubricationproblems in aircraft engines. Thus, this test method is used toensure that the kinematic viscosity does not exceed
9、 themaximum kinematic viscosity in certain specifications foraircraft turbine lubricants.5. Apparatus5.1 Viscometers, drying tubes, low-temperature bath, ther-mometer, timer, secondary viscosity standard, filter, and clean-ing supplies are described in detail in Test Method D 445.5.2 ViscometerThe v
10、iscometer shall meet the require-ments of Test Method D 445 and be of the type in which thesample can be rerun without cleaning the viscometer. Suitableholders should be used. For convenience it is recommendedthat the viscometer size be chosen to keep the efflux timebetween 200 and 1000 s.5.3 Drying
11、 TubesFit the viscometer openings with dryingtubes filled with indicating silica gel, using cotton at top andbottom to hold the loosely packed desiccant in place. Providea cross-connection on the viscometer side of the drying tubes(which can be closed by a pinch clamp or stopcock while liquidis bein
12、g drawn into the efflux bulb) so that the restriction to airflow will not cause error. Replace the silica gel when alavender color is noticeable.5.4 Viscosity Temperature BathThe constant-temperaturebath must be capable of holding several viscometers at once. Itmust have adequate stirring of the liq
13、uid medium (Note 2) andbalance between heat losses such that the bath temperature canbe maintained at the required temperature 60.03C (60.05F).NOTE 2Isopropanol or other clear, low-freezing liquid may be used asa bath liquid.5.5 Low-Temperature Storage CabinetIf it is desired toexercise the option d
14、escribed in Note 3 (7.4), a low-temperature storage cabinet or bath shall be provided which is1This test method is under the jurisdiction of ASTM Committee D02 onPetroleum Products and Lubricants and is the direct responsibility of SubcommitteeD02.07 on Flow Properties.Current edition approved Dec.
15、1, 2003. Published January 2004. Originallyapproved in 1966. Last previous edition approved in 1998 as D 253293 (1998).2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer
16、to the standards Document Summary page onthe ASTM website.1*A Summary of Changes section appears at the end of this standard.Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.capable of holding the required temperature with a variationn
17、ot to exceed 60.3C (60.5F).5.6 Bath ThermometerCalibrated ASTM Kinematic Vis-cosity Test Thermometer such as 73F or 74F conforming to therequirements as prescribed in Specification E1. Other cali-brated thermometric devices are permissible provided theiraccuracy, precision, and sensitivity are equal
18、 to or better thanthe above thermometers.5.7 Secondary Viscosity Standards.36. Procedure for Cleaning Viscometers and Filter Screen6.1 Apply air pressure or suction to the viscometer toremove any previous test specimen. Allow the viscometer todrain for 5 min.6.1.1 Wash the viscometer four times, ins
19、ide and out, withfresh toluene (WarningFlammable) using suction as re-quired. Allow the viscometer to drain.6.1.2 Wash the viscometer four times, inside and out, withacetone, and allow to drain for 5 min. Then dry with suction.6.1.3 Clean the viscometer thoroughly by filling it com-pletely with glas
20、s cleaning solution. Allow to drain for 5 min.6.1.4 Rinse viscometer inside and out with distilled wateruntil all traces of the cleaning solution are completely re-moved. Allow to drain for 5 min.6.1.5 Dry in oven at approximately 100C (212F).6.2 Clean the filter screen by first disassembling the sc
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMD25322003STANDARDTESTMETHODFORVISCOSITYANDVISCOSITYCHANGEAFTERSTANDINGATLOWTEMPERATUREOFAIRCRAFTTURBINELUBRICANTS

链接地址:http://www.mydoc123.com/p-513047.html