ASTM D2364-2001(2007)e1 Standard Test Methods for Hydroxyethylcellulose《羟基乙基纤维素的标准试验方法》.pdf
《ASTM D2364-2001(2007)e1 Standard Test Methods for Hydroxyethylcellulose《羟基乙基纤维素的标准试验方法》.pdf》由会员分享,可在线阅读,更多相关《ASTM D2364-2001(2007)e1 Standard Test Methods for Hydroxyethylcellulose《羟基乙基纤维素的标准试验方法》.pdf(5页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: D 2364 01 (Reapproved 2007)e1Standard Test Methods forHydroxyethylcellulose1This standard is issued under the fixed designation D 2364; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the year of last revision. A numbe
2、r in parentheses indicates the year of last reapproval. Asuperscript epsilon (e) indicates an editorial change since the last revision or reapproval.e1NOTESpecification E 1 was replaced with Specification E 2251 in Section 2 and 20.5 in June 2007.1. Scope1.1 These test methods cover the testing of h
3、ydroxyethyl-cellulose.1.2 The test procedures appear in the following order:SectionsMoisture 4-9Ash 10-17Viscosity 18-24Density 25-311.3 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to estab
4、lish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use.2. Referenced Documents2.1 ASTM Standards:2D 1193 Specification for Reagent WaterD 4794 Test Method for Determination of Ethoxyl or Hy-droxyethoxyl Substitution in Cellulose Ether Pr
5、oducts byGas ChromatographyE 2251 Specification for Liquid-in-Glass ASTM Thermom-eters with Low-Hazard Precision Liquids3. Purity of Reagents3.1 Reagent grade chemicals shall be used in all tests.Unless otherwise indicated, it is intended that all reagents shallconform to the specifications of the C
6、ommittee on AnalyticalReagents of the American Chemical Society,3where suchspecifications are available. Other grades may be used, pro-vided it is first ascertained that the reagent is of sufficientlyhigh purity to permit its use without lessening the accuracy ofthe determination.3.2 Unless otherwis
7、e indicated, reference to water shall beunderstood to mean reagent water, conforming to SpecificationD 1193.MOISTURE4. Scope4.1 This test method covers the determination of the volatilecontent of hydroxyethylcellulose.5. Significance and Use5.1 The results of this test are used for calculating the t
8、otalsolids in the sample; and, by common usage, all materialsvolatile at this test temperature are designated as moisture.5.2 Moisture analysis (along with sulfated ash) is a measureof the amount of active polymer in the material and must beconsidered when determining the amount of hydroxyethylcellu
9、lose to use in various formulations.6. Apparatus6.1 Oven, gravity-convection, capable of maintaining atemperature of 105 6 3C.6.2 Weighing Bottles, low-form, 50 mm in inside diameterby 30 mm in height, or equivalent.6.3 Analytical Balance.7. Procedure7.1 Weigh5gofsample to the nearest 0.001 g in a t
10、ared andcovered weighing bottle.7.2 Place it in an oven at 105C for 2 h with the coverremoved. Replace the cover, cool in a desiccator, and weigh.8. Calculation8.1 Calculate the percent moisture, M, as follows:M 5 A/B! 3 100 (1)1These test methods are under the jurisdiction of ASTM Committee D01 onP
11、aint and Related Coatings, Materials, and Applications and are the directresponsibility of Subcommittee D01.36 on Cellulose and Cellulose Derivatives.Current edition approved June 1, 2007. Published July 2007. Originally approvedin 1965. Last previous edition approved in 2001 as D 2364 01.2For refer
12、enced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.3Reagent Chemicals, American Chemical Society Specifications, AmericanC
13、hemical Society, Washington, DC. For suggestions on the testing of reagents notlisted by the American Chemical Society, see Analar Standards for LaboratoryChemicals, BDH Ltd., Poole, Dorset, U.K., and the United States Pharmacopeiaand National Formulary, U.S. Pharmacopeial Convention, Inc. (USPC), R
14、ockville,MD.1Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.where:A = mass loss on heating, g, andB = sample used, g.9. Precision and Bias9.1 Statistical analysis of intralaboratory (repeatability) testresults on samples containing f
15、rom about 3.5 % moistureindicate a precision of 60.5 % absolute at the 95 % confidencelevel.9.2 No statement on bias can be made as no suitablereference material is available as a standard.ASHAS SULFATE10. Scope10.1 This test method covers the determination of theresidue on ignition of hydroxyethylc
16、ellulose after a specimenhas been treated with sulfuric acid.11. Summary of Test Method11.1 A specimen is moistened with sulfuric acid, the excessacid evaporated, the carbonaceous matter burned off, and theresidue ignited in a muffle furnace, cooled, and weighed.12. Significance and Use12.1 Excessiv
17、e ash can affect solution clarity and filmproperties. The ash (along with moisture) is a measure of theamount of active polymer in the material and must be consid-ered when determining the amount of hydroxyethyl cellulose touse in various formulations.13. Apparatus13.1 Dishes, platinum, 50 to 75-mL
18、capacity.13.2 Muffle Furnace, maintained at 825 6 25C.14. Reagents14.1 Sulfuric Acid (sp gr 1.84)Concentrated sulfuric acid(H2SO4).15. Procedure15.1 Weigh, to the nearest 0.0001 g, about2gofthedriedsample into a tared platinum dish. Moisten the entire specimenwith about 2 mL of H2SO4. Then cautiousl
19、y heat over a smallflame until sulfur trioxide (SO3) fumes cease to be evolved.15.2 Increase the heat, ignite the specimen, and heat asnecessary to burn off the volatile matter. Avoid spattering.15.3 Place the dish in a 825C muffle furnace for 1 h, orlonger if required, to burn all of the carbon.15.
20、4 Remove the dish, allow to cool somewhat, place in adesiccator, and cool to room temperature. Weigh the dish andresidue to the nearest 0.0001 g.16. Calculation16.1 Calculate the percent of ash (as sulfate), C, as follows:C 5 A/B!3 100 (2)where:A = ash, g, andB = sample used, g.17. Precision and Bia
21、s17.1 Statistical analysis of interlaboratory (reproducibility)test results on samples containing 2 to 5 % ash (as sulfate)indicates a precision of 60.3 % absolute at the 95 % level.17.2 No statement on bias can be made as no suitablereference material is available as a standard.VISCOSITY18. Scope18
22、.1 This test method is an arbitrary method of determiningthe viscosity of aqueous solutions of hydroxyethylcellulose inthe viscosity range from 10 to 10 000 cP at 25C.18.2 The concentration to be used for the test shall beagreed upon between the purchaser and the seller. It shall besuch that the vis
23、cosity of the solution will fall within the rangeof this test.18.3 The results for the viscosity of hydroxyethylcelluloseby this test method will not necessarily check with results fromother types of instruments used for viscosity measurements.18.4 The determinations are run on a calculated dry basi
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMD236420012007E1STANDARDTESTMETHODSFORHYDROXYETHYLCELLULOSE 羟基 乙基 纤维素 标准 试验 方法 PDF

链接地址:http://www.mydoc123.com/p-512754.html