ASTM D971-1999a(2004) Standard Test Method for Interfacial Tension of Oil Against Water by the Ring Method《采用环法测定油水界面张力的标准试验方法》.pdf
《ASTM D971-1999a(2004) Standard Test Method for Interfacial Tension of Oil Against Water by the Ring Method《采用环法测定油水界面张力的标准试验方法》.pdf》由会员分享,可在线阅读,更多相关《ASTM D971-1999a(2004) Standard Test Method for Interfacial Tension of Oil Against Water by the Ring Method《采用环法测定油水界面张力的标准试验方法》.pdf(3页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: D 971 99a (Reapproved 2004)Standard Test Method forInterfacial Tension of Oil Against Water by the Ring Method1This standard is issued under the fixed designation D 971; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision,
2、the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon (e) indicates an editorial change since the last revision or reapproval.This standard has been approved for use by agencies of the Department of Defense.1. Scope1.1 This test method covers
3、the measurement of the inter-facial tension between mineral oil and water, under non-equilibrium conditions.1.2 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety
4、and health practices and determine the applica-bility of regulatory limitations prior to use.2. Referenced Documents2.1 ASTM Standards:2D 117 Guide to Test Methods and Specifications for Elec-trical Insulating Oils of Petroleum OriginD 923 Test Method for Sampling Electrical Insulating Liq-uidsD 228
5、5 Test Method for Interfacial Tension of ElectricalInsulating Oils of Petroleum Origin Against Water by theDrop-Weight Method3. Summary of Test Method3.1 Interfacial Tension is determined by measuring theforce necessary to detach a planar ring of platinum wire fromthe surface of the liquid of higher
6、 surface tension, that is,upward from the water-oil interface. To calculate the interfacialtension, the force so measured is corrected by an empiricallydetermined factor which depends upon the force applied, thedensities of both oil and water, and the dimensions of the ring.Measurements are made und
7、er rigidly standardized nonequi-librium conditions in which the measurement is completedwithin 60 s after formation of the interface.4. Significance and Use4.1 Interfacial tension measurements on electrical insulatingoils provide a sensitive means of detecting small amounts ofsoluble polar contamina
8、nts and products of oxidation. A highvalue for new mineral insulating oil indicates the absence ofmost undesirable polar contaminants. The test is frequentlyapplied to service-aged oils as an indication of the degree ofdeterioration.5. Apparatus (Figs. 1 and 2)5.1 Tensiometer3Force measurement on th
9、e tensiometermay be made using a torsion wire, load cell, or any other meansof linearly determining tension in the range of 0 to 100 mN/m.5.1.1 Horizontal platform to hold the sample containershould be capable of movement upward or downward using amechanical screw, lever mechanism, electronic drive,
10、 or anyother means of precisely changing vertical position of thesample.5.2 Rings made of platinum or platinum-iridium alloy maybe used. The ring should be welded into a continuous circle andattached to at least two parallel stirrups. Circumference of thering should be minimum 40 mm and diameter of
11、the ring wireshould be about 0.3 mm. Ratio of the ring major radius (R) andthe wire radius (r) should be known (R/r) to at least threesignificant figures. Stirrups should be at least 25 mm long.5.2.1 The ring may be suspended from or rigidly fixed intothe tensiometer force measuring system.5.3 Sampl
12、e ContainerGlass beaker or clear cylindricalcontainer having a minimum diameter of 45 mm.6. Reagents6.1 Purity of ReagentsReagent grade chemicals shall beused in the test.6.2 Purity of WaterUnless otherwise indicated, referencesto water shall be understood to mean distilled water or water ofequal pu
13、rity.1This test method is under the jurisdiction of ASTM Committee D27 onElectrical Insulating Liquids and Gases and is the direct responsibility of Subcom-mittee D27.07 on Physical Test.Current edition approved Oct. 1, 2004. Published November 2004. Originallyapproved in 1948 as D 971 48 T. Last pr
14、evious edition approved in 1999 asD 971 99a.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.3Tensiometers tha
15、t use the Du Nouy principle for measuring interfacial andsurface tension should be used.1Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.7. Preparation of Apparatus7.1 Glass containers can be cleaned by rinsing in xylene,hexane or ano
16、ther suitable hydrocarbon solvent, followed by arinse in acetone or methyl ethyl ketone. Following these rinsesthey can be cleaned using detergent in hot water and rinsedthoroughly with tap and then distilled water. Dry the glassvessel if not for immediate use.7.2 The ring should be cleaned by immer
17、sing it in a smallcontainer of xylene, hexane or another suitable hydrocarbonsolvent for at least 5 s while spinning the ring back and forth.Next, repeat this rinse using a container filled with acetone ormethyl ethyl ketone. Flame the ring in a gas flame, againspinning it to obtain rapid, uniform h
18、eating. The ring shouldbarely glow orange and should be heated for no more than 5 s.Clean the ring immediately before each measurement.7.3 The tensiometer should be leveled by placing a bubblelevel device on the sample platform, if not equipped with one,and adjusting the tensiometer base until the p
19、latform is level.8. Calibration of Apparatus8.1 Calibrate the tensiometer against known weights andadjust its zero point according to the procedure of its manu-facturer. Make certain that all portions of the ring are in thesame horizontal plane.9. Procedure9.1 Preparation of Test Specimens:9.1.1 Obt
20、ain a representative test specimen of liquid, at least25 mL, to be studied in accordance with Test Method D 923.9.1.2 Obtain a fresh aliquot of distilled water (50 to 75 mL)for interfacial tension measurements.9.1.3 Test specimens should be covered, capped, or sealedimmediately after they are obtain
21、ed. Atmospheric dust andvapor can easily contaminate water, as can the growth ofbacteria. Store test specimen in the dark at ambient tempera-ture.9.2 Determination of Test Specimen Density:9.2.1 Determine test specimen density at 25 6 1C using aliquid pycnometer or other density measuring device to6
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMD9711999A2004STANDARDTESTMETHODFORINTERFACIALTENSIONOFOILAGAINSTWATERBYTHERINGMETHOD 采用 测定 油水 界面

链接地址:http://www.mydoc123.com/p-512612.html