1、Designation: D97 12Designation: 15/95Standard Test Method forPour Point of Petroleum Products1This standard is issued under the fixed designation D97; the number immediately following the designation indicates the year of originaladoption or, in the case of revision, the year of last revision.Anumbe
2、r in parentheses indicates the year of last reapproval.Asuperscriptepsilon () indicates an editorial change since the last revision or reapproval.This standard has been approved for use by agencies of the Department of Defense.1. Scope*1.1 This test method covers and is intended for use on anypetrol
3、eum product.2A procedure suitable for black specimens,cylinder stock, and nondistillate fuel oil is described in 8.8.Thecloud point procedure formerly part of this test method nowappears as Test Method D2500.1.2 Currently there is no ASTM test method for automatedTest Method D97 pour point measureme
4、nts.1.3 Several ASTM test methods offering alternative proce-dures for determining pour points using automatic apparatusare available. None of them share the same designation numberas Test Method D97. When an automatic instrument is used,the ASTM test method designation number specific to thetechniq
5、ue shall be reported with the results. A procedure fortesting the pour point of crude oils is described in Test MethodD5853.1.4 The values stated in SI units are to be regarded asstandard. No other units of measurement are included in thisstandard.1.5 WARNINGMercury has been designated by manyregula
6、tory agencies as a hazardous material that can causecentral nervous system, kidney and liver damage. Mercury, orits vapor, may be hazardous to health and corrosive tomaterials. Caution should be taken when handling mercury andmercury containing products. See the applicable product Ma-terial Safety D
7、ata Sheet (MSDS) for details and EPAswebsitehttp:/www.epa.gov/mercury/faq.htmfor addi-tional information. Users should be aware that selling mercuryand/or mercury containing products into your state or countrymay be prohibited by law.1.6 This standard does not purport to address all of thesafety con
8、cerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use.2. Referenced Documents2.1 ASTM Standards:3D117 Guide for Sampling, Test Methods,
9、 and Specificationsfor Electrical Insulating Oils of Petroleum OriginD396 Specification for Fuel OilsD2500 Test Method for Cloud Point of Petroleum ProductsD5853 Test Method for Pour Point of Crude OilsD6300 Practice for Determination of Precision and BiasData for Use in Test Methods for Petroleum P
10、roducts andLubricantsE1 Specification for ASTM Liquid-in-Glass Thermometers2.2 Energy Institute Standards:Specifications for IP Standard Thermometers43. Terminology3.1 Definitions:3.1.1 black oil, nlubricant containing asphaltic materials.Black oils are used in heavy-duty equipment applications, suc
11、has mining and quarrying, where extra adhesiveness is desired.3.1.2 cylinder stock, nlubricant for independently lubri-cated engine cylinders, such as those of steam engines and aircompressors. Cylinder stock are also used for lubrication ofvalves and other elements in the cylinder area.3.1.3 pour p
12、oint, nin petroleum products, the lowesttemperature at which movement of the test specimen isobserved under prescribed conditions of test.1This test method is under the jurisdiction of ASTM Committee D02 onPetroleum Products and Lubricants and is the direct responsibility of SubcommitteeD02.07 on Fl
13、ow Properties.Current edition approved Dec. 1, 2012. Published March 2013. Originallyapproved in 1927, replacing D47. Last previous edition approved in 2011 asD9711. DOI: 10.1520/D0097-12.In the IP, this test method is under the jurisdiction of the StandardizationCommittee. This test method was adop
14、ted as a joint ASTM-IP Standard in 1965.2Statements defining this test and its significance when applied to electricalinsulating oils of mineral origin will be found in Guide D117.3For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org
15、. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.4Methods forAnalysis and Testing, IP Standards for Petroleum and its Products,Part I, Vol 2.*A Summary of Changes section appears at the end of this standardCopyright ASTM Internati
16、onal, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States13.1.4 residual fuel, na liquid fuel containing bottomsremaining from crude distillation or thermal cracking; some-times referred to as heavy fuel oil.3.1.4.1 DiscussionResidual fuels comprise Grades 4, 5,and 6
17、fuel oils, as defined in Specification D396.4. Summary of Test Method4.1 After preliminary heating, the sample is cooled at aspecified rate and examined at intervals of 3C for flowcharacteristics. The lowest temperature at which movement ofthe specimen is observed is recorded as the pour point.5. Si
18、gnificance and Use5.1 The pour point of a petroleum specimen is an index ofthe lowest temperature of its utility for certain applications.6. Apparatus6.1 Test Jar, cylindrical, of clear glass, flat bottom, 33.2 to34.8-mm outside diameter, and 115 to 125 mm in height. Theinside diameter of the jar ca
19、n range from 30.0 to 32.4 mm,within the constraint that the wall thickness be no greater than1.6 mm. The jar shall have a line to indicate a sample height 546 3 mm above the inside bottom. See Fig. 1.6.2 Thermometers, having the following ranges and con-forming to the requirements prescribed in Spec
20、ification E1 forthermometers:Temperature ThermometerNumberThermometer Range ASTM IPHigh cloud and pour 38 to +50C 5C 1CLow cloud and pour 80 to +20C 6C 2CMelting point +32 to +127C 61C 63C6.2.1 Since separation of liquid column thermometers occa-sionally occurs and may escape detection, thermometers
21、should be checked immediately prior to the test and used onlyif they prove accurate within 61C (for example ice point).6.3 Cork, to fit the test jar, bored centrally for the testthermometer.6.4 Jacket, watertight, cylindrical, metal, flat-bottomed, 1156 3-mm depth, with inside diameter of 44.2 to 45
22、.8 mm. Itshall be supported in a vertical position in the cooling bath (see6.7) so that not more than 25 mm projects out of the coolingmedium, and shall be capable of being cleaned.6.5 Disk, cork or felt, 6 mm thick to fit loosely inside thejacket.6.6 Gasket, to fit snugly around the outside of the
23、test jarand loosely inside the jacket. The gasket may be made ofrubber, leather, or other material that is elastic enough to clingto the test jar and hard enough to hold its shape. Its purpose isto prevent the test jar from touching the jacket.6.7 Bath or Baths, maintained at prescribed temperatures
24、with a firm support to hold the jacket vertical. The requiredNOTE 1Dimensions are in millimetres (not to scale).FIG. 1 Apparatus for Pour Point TestD97122bath temperatures may be obtained by refrigeration ifavailable, otherwise by suitable cooling mixtures. Coolingmixtures commonly used for bath tem
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMD972012STANDARDTESTMETHODFORPOURPOINTOFPETROLEUMPRODUCTS 石油 产品 标准 试验 方法 PDF

链接地址:http://www.mydoc123.com/p-512606.html