ASTM D696-2008 Standard Test Method for Coefficient of Linear Thermal Expansion of Plastics Between -30&176C and 30&176C With a Vitreous Silica Dilatometer《用玻璃硅膨胀计测定塑料在-30℃和30℃之间的线.pdf
《ASTM D696-2008 Standard Test Method for Coefficient of Linear Thermal Expansion of Plastics Between -30&176C and 30&176C With a Vitreous Silica Dilatometer《用玻璃硅膨胀计测定塑料在-30℃和30℃之间的线.pdf》由会员分享,可在线阅读,更多相关《ASTM D696-2008 Standard Test Method for Coefficient of Linear Thermal Expansion of Plastics Between -30&176C and 30&176C With a Vitreous Silica Dilatometer《用玻璃硅膨胀计测定塑料在-30℃和30℃之间的线.pdf(5页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: D 696 08Standard Test Method forCoefficient of Linear Thermal Expansion of PlasticsBetween 30C and 30C with a Vitreous Silica Dilatometer1This standard is issued under the fixed designation D 696; the number immediately following the designation indicates the year oforiginal adoption or
2、, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.This standard has been approved for use by agencies of the Department of Defense.1. Scope*1
3、.1 This test method covers determination of the coefficientof linear thermal expansion for plastic materials having coef-ficients of expansion greater than 1 3 106/C by use of avitreous silica dilatometer. At the test temperatures and underthe stresses imposed, the plastic materials shall have a neg
4、li-gible creep or elastic strain rate or both, insofar as theseproperties would significantly affect the accuracy of the mea-surements.NOTE 1There is no similar or equivalent ISO standard.1.1.1 Test Method E 228 shall be used for temperaturesother than 30C to 30C.1.1.2 This test method shall not be
5、used for measurementson materials having a very low coefficient of expansion (lessthan 1 3 106/C). For materials having very low coefficient ofexpansion, interferometer or capacitance techniques are rec-ommended.1.2 The thermal expansion of a plastic is composed of areversible component on which are
6、 superimposed changes inlength due to changes in moisture content, curing, loss ofplasticizer or solvents, release of stresses, phase changes andother factors. This test method is intended for determining thecoefficient of linear thermal expansion under the exclusion ofthese factors as far as possib
7、le. In general, it will not bepossible to exclude the effect of these factors completely. Forthis reason, the test method can be expected to give only anapproximation to the true thermal expansion.1.3 The values stated in SI units are to be regarded asstandard. The values in parentheses are for info
8、rmation only.1.4 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use.2.
9、 Referenced Documents2.1 ASTM Standards:2D 618 Practice for Conditioning Plastics for TestingD 883 Terminology Relating to PlasticsD 4065 Practice for Plastics: Dynamic Mechanical Proper-ties: Determination and Report of ProceduresE 228 Test Method for Linear Thermal Expansion of SolidMaterials With
10、 a Push-Rod DilatometerE 691 Practice for Conducting an Interlaboratory Study toDetermine the Precision of a Test MethodE 831 Test Method for Linear Thermal Expansion of SolidMaterials by Thermomechanical Analysis3. Terminology3.1 DefinitionsDefinitions are in accordance with Termi-nology D 883 unle
11、ss otherwise specified.4. Summary of Test Method4.1 This test method is intended to provide a means ofdetermining the coefficient of linear thermal expansion ofplastics which are not distorted or indented by the thrust of thedilatometer on the specimen. For materials that indent, see 8.4.The specime
12、n is placed at the bottom of the outer dilatometertube with the inner one resting on it. The measuring devicewhich is firmly attached to the outer tube is in contact with thetop of the inner tube and indicates variations in the length ofthe specimen with changes in temperature. Temperaturechanges ar
13、e brought about by immersing the outer tube in aliquid bath or other controlled temperature environment main-tained at the desired temperature.5. Significance and Use5.1 The coefficient of linear thermal expansion, a, betweentemperatures T1and T2for a specimen whose length is L0atthe reference tempe
14、rature, is given by the following equation:1This test method is under the jurisdiction ofASTM Committee D20 on Plasticsand is the direct responsibility of Subcommittee D20.30 on Thermal Properties(Section D20.30.07).Current edition approved Nov. 1, 2008. Published November 2008. Originallyapproved i
15、n 1942. Last previous edition approved in 2003 as D 696 03.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.1*
16、A Summary of Changes section appears at the end of this standard.Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.a5L22 L1!/L0T22T1!# 5DL/L0DTwhere L1and L2are the specimen lengths at temperatures T1and T2, respectively. a is, therefor
17、e, obtained by dividing thelinear expansion per unit length by the change in temperature.5.2 The nature of most plastics and the construction of thedilatometer make 30 to +30C (22F to +54F) a convenienttemperature range for linear thermal expansion measurementsof plastics. This range covers the temp
18、eratures in whichplastics are most commonly used. Where testing outside of thistemperature range or when linear thermal expansion character-istics of a particular plastic are not known through thistemperature range, particular attention shall be paid to thefactors mentioned in 1.2 and special prelim
19、inary investigationsby thermo-mechanical analysis, such as that prescribed inPractice D 4065 for the location of transition temperatures,may be required to avoid excessive error. Other ways oflocating phase changes or transition temperatures using thedilatometer itself may be employed to cover the r
20、ange oftemperatures in question by using smaller steps than 30C(54F) or by observing the rate of expansion during a steadyrise in temperature of the specimen. Once such a transitionpoint has been located, a separate coefficient of expansion fora temperature range below and above the transition point
21、 shallbe determined. For specification and comparison purposes, therange from 30C to +30C (22F to +86F) (provided it isknown that no transition exists in this range) shall be used.6. Apparatus6.1 Fused-Quartz-Tube Dilatometer suitable for this testmethod is illustrated in Fig. 1. A clearance of appr
22、oximately 1mm is allowed between the inner and outer tubes.6.2 Device for measuring the changes in length (dial gage,LVDT, or the equivalent) is fixed on the mounting fixture sothat its position may be adjusted to accommodate specimens ofvarying length (see 8.2). The accuracy shall be such that thee
23、rror of indication will not exceed 61.0 m (4 3 105in.) forany length change. The weight of the inner silica tube plus themeasuring device reaction shall not exert a stress of more than70 kPa (10 psi) on the specimen so that the specimen is notdistorted or appreciably indented.6.3 Scale or Caliper ca
24、pable of measuring the initial lengthof the specimen with an accuracy of 60.5 %.6.4 Controlled Temperature Environment to control thetemperature of the specimen. Arrange the bath so a uniformFIG. 1 Quartz-Tube DilatometerD696082temperature is assured over the length of the specimen. Meansshall be pr
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMD6962008STANDARDTESTMETHODFORCOEFFICIENTOFLINEARTHERMALEXPANSIONOFPLASTICSBETWEEN30176CAND30176CWITHAVITREOUSSILICADILATOMETER

链接地址:http://www.mydoc123.com/p-512058.html