ASTM D1876-2008 Standard Test Method for Peel Resistance of Adhesives (T-Peel Test)《胶粘剂的抗剥离性的标准试验方法(T型剥离试验)》.pdf
《ASTM D1876-2008 Standard Test Method for Peel Resistance of Adhesives (T-Peel Test)《胶粘剂的抗剥离性的标准试验方法(T型剥离试验)》.pdf》由会员分享,可在线阅读,更多相关《ASTM D1876-2008 Standard Test Method for Peel Resistance of Adhesives (T-Peel Test)《胶粘剂的抗剥离性的标准试验方法(T型剥离试验)》.pdf(3页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: D 1876 08Standard Test Method forPeel Resistance of Adhesives (T-Peel Test)1This standard is issued under the fixed designation D 1876; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the year of last revision. A numbe
2、r in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.This standard has been approved for use by agencies of the Department of Defense.INTRODUCTIONThe accuracy of the results of strength tests of adhesive b
3、onds will depend on the conditions underwhich the bonding process is carried out. Unless otherwise agreed upon by the manufacturer and thepurchaser, the bonding conditions shall be prescribed by the manufacturer of the adhesive. In order toensure that complete information is available to the individ
4、ual conducting the tests, the manufacturerof the adhesive shall furnish numerical values and other specific information for each of the followingvariables:(1) Procedure for preparation of the surfaces prior to application of the adhesive, the cleaning anddrying of metal surfaces, and special surface
5、 treatments such as sanding, which are not specificallylimited by the pertinent test method.(2) Complete mixing directions for the adhesive.(3) Conditions for application of the adhesive, including the rate of spread or thickness of film,number of coats to be applied, whether to be applied to one or
6、 both surfaces, and the conditions ofdrying where more than one coat is required.(4) Assembly conditions before application of pressure, including the room temperature, length oftime, and whether open or closed assembly is to be used.(5) Curing conditions, including the amount of pressure to be appl
7、ied, the length of time underpressure, and the temperature of the assembly when under pressure. It should be stated whether thistemperature is that of the glue line, or of the atmosphere at which the assembly is to be maintained.(6) Conditioning procedure before testing, unless a standard procedure
8、is specified, including thelength of time, temperature, and relative humidity.Arange may be prescribed for any variable by the manufacturer of the adhesive, if it can be assumedby the test operator that any arbitrarily chosen value within such a range or any combination of suchvalues for several var
9、iables will be acceptable to both the manufacturer and the purchaser of theadhesive.1. Scope1.1 This test method is primarily intended for determiningthe relative peel resistance of adhesive bonds between flexibleadherends by means of a T-type specimen.1.2 The values stated in SI units are to be reg
10、arded as thestandard. The values given in parentheses are provided forinformation purposes only.1.3 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health p
11、ractices and determine the applica-bility of regulatory limitations prior to use.2. Referenced Documents2.1 ASTM Standards:2B 209 Specification for Aluminum and Aluminum-AlloySheet and PlateD 907 Terminology of Adhesives1This test method is under the jurisdiction of ASTM Committee D14 onAdhesives an
12、d is the direct responsibility of D14.80 on Metal Bonding Adhesives.Current edition approved Oct. 1, 2008. Published October 2008. Originallyapproved in 1961. Last previous edition approved in 2001 as D 1876 01.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Cust
13、omer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.1Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.3. Terminology3.1 DefinitionsMany t
14、erms in this test method are definedin Terminology D 907.3.1.1 peel strength, nthe average load per unit width ofbondline required to separate progressively a flexible memberfrom a rigid member or another flexible member.3.1.1.1 DiscussionFlexible has different meanings in dif-ferent peel tests, suc
15、h as “T,” 180-degree, floating-roller, orclimbing-drum. The angle between the members varies withthe type of peel test.3.2 Definitions of Terms Specific to This Standard:3.2.1 flexible, adjindicates that the adherends shall havesuch dimensions and physical properties as to permit bendingthem through
16、 any angle up to 90 without breaking or cracking.3.2.2 T-peel strength, nthe average load per unit width ofbond line required to produce progressive separation of twobonded, flexible adherends, under conditions designated in thistest method.4. Apparatus4.1 Tension Testing Machine, capable of applyin
17、g a tensileload having the following prescribed conditions:4.1.1 The machine and loading range selected that themaximum load on the specimen falls between 15 and 85 % ofthe upper limit of the loading range.4.1.2 The rate of movement between heads essentiallyconstant under fluctuating loads.NOTE 1It
18、is difficult to meet this requirement when loads aremeasured with a spring-type or pendulum-type weighing device.4.1.3 The machine equipped with suitable grips capable ofclamping the specimens firmly and without slippage through-out the tests.4.1.4 The machine shall be autographic, giving a chart th
19、atcan be read in terms of inches of separation as one coordinateand applied load as the other coordinate.4.1.5 The applied tension as measured and recorded accu-rate to 61 % of any reading when calibrated in compliancewith Practices E 4 requirements.4.2 Conditioning Room or DesiccatorsThe conditioni
20、ngroom or desiccators (Note 2) shall be capable of maintaining arelative humidity of 50 6 2 % at 23 6 1C (73.4 6 1.8F).NOTE 2A saturated solution of calcium nitrate will give approxi-mately 51 % relative humidity at the testing temperature.5. Test Specimen5.1 Laminated test panels (see Fig. 1) consi
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMD18762008STANDARDTESTMETHODFORPEELRESISTANCEOFADHESIVESTPEELTEST 胶粘剂 剥离 标准 试验 方法 PDF

链接地址:http://www.mydoc123.com/p-510613.html