1、Designation: D1691 02 (Reapproved 2007)1D1691 12Standard Test Methods forZinc in Water1This standard is issued under the fixed designation D1691; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the year of last revision. A number i
2、n parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.This standard has been approved for use by agencies of the Department of Defense.1 NOTEPractice D2777 98 was editorially changed throughout to D2777 06 in
3、August 2007.1. Scope Scope*1.1 These test methods cover the determination of zinc in water. Two test methods are given as follows:Test Method ConcentrationRangeSectionsAAtomic Absorption, Direct 0.05 to 2 mg/L 8-16BAtomic Absorption,Chelation-Extraction20 to 200 g/L 17-251.2 Either dissolved or tota
4、l recoverable zinc may be determined.1.3 These test methods have been used successfully with reagent grade water. See the specific test method for applicability toother matrices. It is the users responsibility to assure the validity of these test methods in other matrices.1.4 The values stated in ei
5、ther SI units or inch-pound units are to be regarded separately as standard. The values stated in eachsystem are mathematical conversions and may not be exact equivalents; therefore, each system shall be used independently of theother.1.5 This standard does not purport to address all of the safety c
6、oncerns, if any, associated with its use. It is the responsibilityof the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatorylimitations prior to use. For specific hazard statements, see Section 6 and Note 56, Note 810, and Note 131
7、6.1.6 Two former colorimetric test methods were discontinued. Refer to Appendix X1 for historical information.2. Referenced Documents2.1 ASTM Standards:2D858 Test Methods for Manganese in WaterD1066 Practice for Sampling SteamD1068 Test Methods for Iron in WaterD1129 Terminology Relating to WaterD11
8、92 Guide for Equipment for Sampling Water and Steam in Closed Conduits (Withdrawn 2003)3D1193 Specification for Reagent WaterD1687 Test Methods for Chromium in WaterD1688 Test Methods for Copper in WaterD1886 Test Methods for Nickel in WaterD2777 Practice for Determination of Precision and Bias of A
9、pplicable Test Methods of Committee D19 on WaterD3370 Practices for Sampling Water from Closed ConduitsD3557 Test Methods for Cadmium in WaterD3558 Test Methods for Cobalt in WaterD3559 Test Methods for Lead in WaterD4841 Practice for Estimation of Holding Time for Water Samples Containing Organic a
10、nd Inorganic Constituents1 These test methods are under the jurisdiction of ASTM Committee D19 on Water and are the direct responsibility of Subcommittee D19.05 on Inorganic Constituentsin Water.Current edition approved Aug. 1, 2007Sept. 1, 2012. Published August 2007September 2012. Originally appro
11、ved in 1959. Last previous edition approved in 2002 asD1691 02.D1691 02(2007)E01. DOI: 10.1520/D1691-02R07E01.10.1520/D1691-12.2 For referencedASTM standards, visit theASTM website, www.astm.org, or contactASTM Customer Service at serviceastm.org. For Annual Book of ASTM Standardsvolume information,
12、 refer to the standards Document Summary page on the ASTM website.This document is not an ASTM standard and is intended only to provide the user of an ASTM standard an indication of what changes have been made to the previous version. Becauseit may not be technically possible to adequately depict al
13、l changes accurately, ASTM recommends that users consult prior editions as appropriate. In all cases only the current versionof the standard as published by ASTM is to be considered the official document.*A Summary of Changes section appears at the end of this standardCopyright ASTM International, 1
14、00 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States1D5810 Guide for Spiking into Aqueous SamplesD5847 Practice for Writing Quality Control Specifications for Standard Test Methods for Water Analysis3. Terminology3.1 DefinitionsFor definitions of terms used in these tes
15、t methods, refer to Terminology D1129.3.2 Definitions:3.2.1 total recoverable zinczinc, nan arbitrary analytical term relating to the recoverable form of zinc that is determinableby the digestion method whichthat is included in the Procedure.4. Significance and Use4.1 Zinc is an essential and benefi
16、cial element in body growth. Concentrations above 5 mg/L can cause a bitter astringent tasteand opalescence in alkaline waters. The zinc concentration of U.S. drinking waters varies between 0.06 and 7.0 mg/L with a meanof 1.33 mg/L. Zinc most commonly enters the domestic water supply from deteriorat
17、ion of galvanized iron and dezincification ofbrass. Zinc in water also may result from industrial water pollution.35. Purity of Reagents5.1 Reagent grade chemicals shall be used in all tests. Unless otherwise indicated, it is intended that all reagents shall conformto the specifications of the Commi
18、ttee on Analytical Reagents of the American Chemical Society, where such specifications areavailable.4 Other grades may be used, provided it is first ascertained that the reagent is of sufficiently high purity to permit its usewithout lessening the accuracy of the determination.5.2 Purity of WaterUn
19、less otherwise indicated, references to water shall be understood to mean reagent water conforming toSpecification D1193, Type I. Other reagent water types may be used, provided it is first ascertained that the water is of sufficientlyhigh purity to permit its use without adversely affecting the bia
20、s and precision of the test method. Type II water was specified atthe time of round-robin testing of this test method.6. Hazards6.1 Although zinc is nontoxic to man, these test methods require the use of certain other toxic and hazardous reagents andmaterials. Each should be used with care and exert
21、ing proper precautions.7. Sampling7.1 Collect the sample in accordance with Practice D1066, Specification D1192, and Practices D3370, as applicable.7.2 Samples shall be preserved with nitric acid (HNO3) (sp gr 1.42) to a pH of 2 or less immediately at the time of collection,normally about 2 mL/L of
22、HNO3. If only dissolved zinc is to be determined, the sample, shall be filtered through a 0.45-mmembrane filter before acidification. The holding time for samples may be calculated in accordance with Practice D4841.NOTE 1Alternatively, the pH may be adjusted in the laboratory if the sample is return
23、ed within 14 days. This could reduce hazards of working withacids in the field when appropriate.TEST METHOD AATOMIC ABSORPTION, DIRECT8. Scope8.1 This test method covers the determination of dissolved and total recoverable zinc in most waters and wastewaters.8.2 This test method is applicable in the
24、 range from 0.05 to 2.0 mg/L of zinc. The range may be extended to concentrationsgreater than 2.0 mg/L by dilution of the sample.8.3 This test method has been used successfully with reagent grade water, river water, wastewater, ground water, tap water, lakewater, refinery effluent. The information o
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMD16912012STANDARDTESTMETHODSFORZINCINWATER 水中 标准 试验 方法 PDF

链接地址:http://www.mydoc123.com/p-510310.html