ASTM D1412 D1412M-2017a Standard Test Method for Equilibrium Moisture of Coal at 96 to 97 Percent Relative Humidity and 30&x2009 &xb0 C《相对湿度96%至97%和30℃的煤炭平衡湿度的标准试验方法》.pdf
《ASTM D1412 D1412M-2017a Standard Test Method for Equilibrium Moisture of Coal at 96 to 97 Percent Relative Humidity and 30&x2009 &xb0 C《相对湿度96%至97%和30℃的煤炭平衡湿度的标准试验方法》.pdf》由会员分享,可在线阅读,更多相关《ASTM D1412 D1412M-2017a Standard Test Method for Equilibrium Moisture of Coal at 96 to 97 Percent Relative Humidity and 30&x2009 &xb0 C《相对湿度96%至97%和30℃的煤炭平衡湿度的标准试验方法》.pdf(7页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: D1412/D1412M 17D1412/D1412M 17aStandard Test Method forEquilibrium Moisture of Coal at 96 to 97 Percent RelativeHumidity and 30 C1This standard is issued under the fixed designation D1412/D1412M; the number immediately following the designation indicates theyear of original adoption or,
2、 in the case of revision, the year of last revision. A number in parentheses indicates the year of lastreapproval. A superscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope Scope*1.1 This test method covers determination of the equilibrium moisture of coal
3、 in an atmosphere over a saturated solution ofpotassium sulfate at 30 C.NOTE 1For information concerning the experimental work on which this test method is based, see (1-5).21.2 The values stated in either SI units or inch-pound units are to be regarded separately as standard. The values stated in e
4、achsystem may not be exact equivalents; therefore, each system shall be used independently of the other. Combining values from thetwo systems may result in non-conformance with the standard.1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It
5、is the responsibilityof the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatorylimitations prior to use.1.4 This international standard was developed in accordance with internationally recognized principles on standardizationestabl
6、ished in the Decision on Principles for the Development of International Standards, Guides and Recommendations issuedby the World Trade Organization Technical Barriers to Trade (TBT) Committee.2. Referenced Documents2.1 ASTM Standards:3D121 Terminology of Coal and CokeD388 Classification of Coals by
7、 RankD2013 Practice for Preparing Coal Samples for AnalysisD2234/D2234M Practice for Collection of a Gross Sample of CoalD3172 Practice for Proximate Analysis of Coal and CokeD3173 Test Method for Moisture in the Analysis Sample of Coal and CokeD3302 Test Method for Total Moisture in CoalD4596 Pract
8、ice for Collection of Channel Samples of Coal in a MineE177 Practice for Use of the Terms Precision and Bias in ASTM Test MethodsE691 Practice for Conducting an Interlaboratory Study to Determine the Precision of a Test Method3. Significance and Use3.1 This test method affords a means of estimating
9、the inherent moisture of either coal that is wet and shows visible surfacemoisture or coal that may have lost some moisture. It may be used for estimating the surface, or extraneous moisture of wet coal,such moisture being the difference between the total moisture as determined by Test Method D3302
10、and the equilibrium moisture.3.2 When samples are collected in conformity with Classification D388, the equilibrium moisture is considered to be equal tobed moisture with the exception of some low rank coals that yield equilibrium moisture values below bed moisture.3.3 The results obtained by this t
11、est method are sensitive to many influences, and therefore, raw (uncorrected) equilibriummoisture data may be of limited value in and of themselves. When working with low rank coals, the results yielded by this test1 This test method is under the jurisdiction of ASTM Committee D05 on Coal and Coke a
12、nd is the direct responsibility of Subcommittee D05.21 on Methods of Analysis.Current edition approved June 1, 2017Aug. 1, 2017. Published June 2017August 2017. Originally approved in 1956. Last previous edition approved in 20152017 asD1412 15.D1412/D1412M 17. DOI: 10.1520/D1412_D1412M-17.10.1520/D1
13、412_D1412M-17a.2 The boldface numbers in parentheses refer to a list of references at the end of this standard.3 For referencedASTM standards, visit theASTM website, www.astm.org, or contactASTM Customer Service at serviceastm.org. For Annual Book of ASTM Standardsvolume information, refer to the st
14、andards Document Summary page on the ASTM website.This document is not an ASTM standard and is intended only to provide the user of an ASTM standard an indication of what changes have been made to the previous version. Becauseit may not be technically possible to adequately depict all changes accura
15、tely, ASTM recommends that users consult prior editions as appropriate. In all cases only the current versionof the standard as published by ASTM is to be considered the official document.*A Summary of Changes section appears at the end of this standardCopyright ASTM International, 100 Barr Harbor D
16、rive, PO Box C700, West Conshohocken, PA 19428-2959. United States1method require critical assessments. It is recommended that the procedure outlined in the Appendix X1 be applied, and the resultscorrected before use in situations where a more reliable estimation inherent or bed moisture for low ran
17、k coals is required. TheAppendix also provides useful quality assurance information which is applicable to coals of all ranks.4. Apparatus4.1 Water Bath or Insulated Air CabinetThe bath or cabinet shall be of sufficient size to accommodate several vacuum-typedesiccators, and shall be provided with a
18、 temperature regulator to maintain a uniform temperature of 30.0 C 30.0 C 6 0.2 C.4.2 Moisture OvenThe oven shall be so constructed as to have a uniform temperature in all parts and a minimum of air space.It may be of the type shown in the Apparatus section of Test Method D3173. Provision shall be m
19、ade for renewing the air (or, ifdesired, dry oxygen-free nitrogen for subbituminous and lignitic coals) in the oven at a rate of two times per minute, with the airdried as defined in 5.1.4.3 Mechanical Vacuum Pump.4.4 Crusher, laboratory, coffee-mill type.4.5 Sieve, 203 mm 8 in. diameter, with 2.36
20、mm No. 8 openings.4.6 Shaking Machine.4.7 Desiccators:4.7.1 High Vacuum DesiccatorSmall vacuum-type desiccator, approximately 160 mm in diameter, when used in conjunctionwith a saturated K2SO4 solution provides the necessary humidity for the test conditions (see Fig. 1).4.7.2 Cooling DesiccatorCabin
21、et-type desiccator, when used with any of the desiccants (5.2.1 5.2.3) allows the dried testsample to cool to room temperature without substantial regain in mass from adsorption of atmospheric moisture.4.8 Weighing Bottles, glass, low-form, flat-bottom, cylindrical, 70 mm in diameter, with well-fitt
22、ing covers.4.9 Filter Pump, aspirator.4.10 Buchner-Type Funnel, approximately 64 mm 212 in. in diameter.5. Reagents5.1 Drying AtmospheresThe atmosphere used to purge the drying oven is either dry air or dry nitrogen as specified in 5.1.1or 5.1.2.FIG. 1 Vacuum-Type DesiccatorD1412/D1412M 17a25.1.1 Dr
23、y AirAir with a moisture content of content of 1.9 mgL or less passed through a drying column containing any ofthe appropriate desiccants listed in 5.2.5.1.2 Dry NitrogenCompressed nitrogen gas certified having an oxygen content less than 30 L/Land passed through a dryingcolumn containing any of the
24、 appropriate desiccants listed in 5.2.5.2 DesiccantsMaterials suitable for use in the desiccator may be chosen from the following:5.2.1 Anhydrous Calcium Sulfate (0.004 mg/L).5.2.2 Silica Gel.5.2.3 Magnesium Perchlorate (0.0005 mg/L).5.2.4 Sulfuric Acid, Concentrated (0.003 mg/L).5.2.5 The desiccant
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMD1412D1412M2017ASTANDARDTESTMETHODFOREQUILIBRIUMMOISTUREOFCOALAT96TO97PERCENTRELATIVEHUMIDITYAND30X2009XB0C

链接地址:http://www.mydoc123.com/p-509756.html