ASTM D1229-2003(2008) Standard Test Method for Rubber Property-Compression Set at Low Temperatures《橡胶特性 在低温时压缩率的标准试验方法》.pdf
《ASTM D1229-2003(2008) Standard Test Method for Rubber Property-Compression Set at Low Temperatures《橡胶特性 在低温时压缩率的标准试验方法》.pdf》由会员分享,可在线阅读,更多相关《ASTM D1229-2003(2008) Standard Test Method for Rubber Property-Compression Set at Low Temperatures《橡胶特性 在低温时压缩率的标准试验方法》.pdf(3页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: D 1229 03 (Reapproved 2008)Standard Test Method forRubber PropertyCompression Set at Low Temperatures1This standard is issued under the fixed designation D 1229; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the year
2、 of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.This standard has been approved for use by agencies of the Department of Defense.1. Scope1.1 This test method covers evaluatio
3、n of the ability ofvulcanized rubbers that have been compressed at room tem-perature and then subjected to low temperature (air or carbondioxide atmosphere), to recover from deformation when takenfrom the clamping device while still at the low temperature.1.2 The values stated in SI units are to be
4、regarded as thestandard. The values given in parentheses are for informationonly.1.3 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and de
5、termine the applica-bility of regulatory limitations prior to use.2. Referenced Documents2.1 ASTM Standards:2D 395 Test Methods for Rubber PropertyCompressionSetD 832 Practice for Rubber Conditioning For Low Tempera-ture TestingD 3767 Practice for RubberMeasurement of DimensionsD 4483 Practice for E
6、valuating Precision for Test MethodStandards in the Rubber and Carbon Black ManufacturingIndustries3. Summary of Test Method3.1 At room temperature, a test specimen is compressed to25 % of its original thickness and exposed for a specified timeat a specified low temperature.3.2 Upon release from com
7、pression, the specimen is al-lowed to recover while remaining at the test temperature.3.3 The residual deformation of the specimen is measured10 s and 30 min after removal from the compressive device.3.4 Compression set of the specimen is calculated accordingto the equations in 9.1.4. Significance a
8、nd Use4.1 Rubber products, such as hydraulic seals on aircraft,submarine hatch gaskets, and hydraulic brake cups, may beexposed to varying temperature extremes. This test methodprovides a means of determining the extent to which recoveryfrom compression at normal ambient temperatures is inhibitedupo
9、n release of the compressive force during subsequentexposure at low temperatures.5. Compression Set5.1 For the purpose of this test method, compression set ofvulcanizates shall be the loss in thickness of the specimenexpressed as a percentage of the original deflection. This set,unlike conventional
10、compression set at elevated temperatures,is temporary since the specimen will regain its originaldimensions when brought back to room temperature or slightlyabove.6. Apparatus6.1 Compression Set Jigs, with suitable steel spacer bars inaccordance with Method B of Test Methods D 395.6.2 Dial Micromete
11、r, as described in Practice D 3767.6.3 Cold Box, cooled by solid carbon dioxide (Dry Ice),liquid carbon dioxide, liquid nitrogen, or mechanically refrig-erated, preferably by the top-opening type, and capable oftemperature control within 61C (1.8F) of the specifiedtesting temperature as prescribed i
12、n Practice D 832. The testchamber shall be equipped with a vise, “C” clamp, or othersuitable device for holding the compression set jig.7. Test Specimen7.1 The standard test specimen shall be a cylindrical disk29.0 6 0.5 mm (1.14 6 0.02 in.) in diameter and 12.5 6 0.5mm (0.49 6 0.02 in.) in thicknes
13、s, as specified in Test MethodsD 395.8. Procedure8.1 Original Thickness MeasurementMeasure the originalthickness, to, at the center of the specimen to the nearest 0.02mm (0.001 in.).1This test method is under the jurisdiction of ASTM Committee D11 on Rubberand is the direct responsibility of Subcomm
14、ittee D11.14 on Time and Temperature-Dependent Physical Properties.Current edition approved May 1, 2008. Published June 2008. Originallyapproved in 1952. Last previous edition approved in 2003 as D 1229 03.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer
15、Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.1Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.8.2 Application of LoadPlace a test spec
16、imen betweenclean, unlubricated plates of the compression device with thespacers on each side of it. Use only one specimen with eachpair of steel plates, and place in the center between the plates.Tighten the bolts so as to draw the plates together uniformlyuntil they are in contact with the spacers
17、. The compressionemployed shall be 25 % for all hardnesses.8.3 Within 30 min after the jigs are loaded, place them in thelow-temperature cabinet, and maintain at the service tempera-ture for which the vulcanizates are being evaluated. In theevent the service temperature is unknown, the followingtemp
18、eratures are suggested: 40C (40F) and 55C(67F). The conditioning period shall be either 22 or 94 h. Atleast 1 h before the conditioning period is over, place the dialmicrometer in the test chamber and clamp one of the set jigs inthe vise or “C” clamp provided in the low-temperature cham-ber. Use sui
19、table gloves for all operations in the test chamber.At the end of the conditioning period, remove the nuts from thejig, after which release the vise or “C” clamp, and start the stopwatch simultaneously. Measure the thickness of the specimens10 s and again 30 min after release from the vise or “C” cl
20、ampand record as t10and t30, respectively. Since the test isconducted at a specific temperature, within 61C (1.8F), theschedule of opening the jigs shall be such that the test chamberwill stay within the permissible variations in temperature.NOTE 1It is convenient when conducting many tests to have
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMD122920032008STANDARDTESTMETHODFORRUBBERPROPERTYCOMPRESSIONSETATLOWTEMPERATURES 橡胶 特性 低温 压缩率 标准 试验

链接地址:http://www.mydoc123.com/p-509475.html