1、Designation: D1125 95 (Reapproved 2009)D1125 14Standard Test Methods forElectrical Conductivity and Resistivity of Water1This standard is issued under the fixed designation D1125; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the
2、 year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.This standard has been approved for use by agencies of the U.S. Department of Defense.1. Scope1.1 These test methods cove
3、r the determination of the electrical conductivity and resistivity of water.The following test methodsare included:Range SectionsTest Method AField and Routine Laboratory 10 to 200 000 12 to 18Test Method AField and Routine Laboratory 10 to 200 000 12 to 18Measurement of Static (Non-Flowing)SamplesS
4、/cmTest Method BContinuous In-Line Measure 5 to 200 000 19 to 23Test Method BContinuous In-Line Measure 5 to 200 000 19 to 23ment S/cmment S/cm1.2 These test methods have been tested in reagent water. It is the users responsibility to ensure the validity of these testmethods for waters of untested m
5、atrices.1.3 For measurements below the range of these test methods, refer to Test Method D5391.1.4 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.1.5 This standard does not purport to address all of the safety concerns, if an
6、y, associated with its use. It is the responsibilityof the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatorylimitations prior to use.2. Referenced Documents2.1 ASTM Standards:2D1066 Practice for Sampling SteamD1129 Terminology Re
7、lating to WaterD1192 Guide for Equipment for Sampling Water and Steam in Closed Conduits (Withdrawn 2003)3D1193 Specification for Reagent WaterD2186 Test Methods for Deposit-Forming Impurities in SteamD2777 Practice for Determination of Precision and Bias of Applicable Test Methods of Committee D19
8、on WaterD3370 Practices for Sampling Water from Closed ConduitsD4519 Test Method for On-Line Determination of Anions and Carbon Dioxide in High Purity Water by Cation Exchange andDegassed Cation ConductivityD5391 Test Method for Electrical Conductivity and Resistivity of a Flowing High Purity Water
9、SampleE1E2251 Specification for ASTM Liquid-in-Glass ThermometersLiquid-in-Glass ASTM Thermometers with Low-HazardPrecision Liquids3. Terminology3.1 Definitions:1 These test methods are under the jurisdiction of Committee D19 on Water and are the direct responsibility of Subcommittee D19.03 on Sampl
10、ingWater andWater-FormedDeposits, Analysis of Water for Power Generation and Process Use, On-Line Water Analysis, and Surveillance of Water.Current edition approved May 1, 2009Feb. 1, 2014. Published June 2009March 2014. Originally approved in 1950. Last previous edition approved in 20052009 asD1125
11、 95 (2009). (2005). DOI: 10.1520/D1125-95R09.10.1520/D1125-14.2 For referencedASTM standards, visit theASTM website, www.astm.org, or contactASTM Customer Service at serviceastm.org. For Annual Book of ASTM Standardsvolume information, refer to the standards Document Summary page on the ASTM website
12、.3 The last approved version of this historical standard is referenced on www.astm.org.This document is not an ASTM standard and is intended only to provide the user of an ASTM standard an indication of what changes have been made to the previous version. Becauseit may not be technically possible to
13、 adequately depict all changes accurately, ASTM recommends that users consult prior editions as appropriate. In all cases only the current versionof the standard as published by ASTM is to be considered the official document.Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Cons
14、hohocken, PA 19428-2959. United States13.1.1 electrical conductivityconductivity, nthe reciprocal of the a-c resistance in ohms measured between opposite faces ofa centimetre cube of an aqueous solution at a specified temperature.NOTE 1The unit of electrical conductivity is siemens per centimetre. (
15、The previously used units of mhos/cm are numerically equivalent to S/cm.)The actual resistance of the cell, Rx, is measured in ohms. The conductance, 1/Rx, is directly proportional to the cross-sectional area, A (in cm 2), andinversely proportional to the length of the path, L (in cm):1/Rx 5KA/L3.1.
16、1.1 DiscussionThe unit of electrical conductivity is siemens per centimetre. (The previously used units of mhos/cm are numerically equivalentto S/cm.) The actual resistance of the cell, Rx, is measured in ohms. The conductance, 1/Rx, is directly proportional to thecross-sectional area, A (in cm2), a
17、nd inversely proportional to the length of the path, L (in cm):1/Rx 5KA/LThe conductance measured between opposite faces of a centimetre cube, K, is called conductivity. Conductivity values areusually expressed in microsiemens/centimetre or in siemens/centimetre at a specified temperature, normally
18、25C.The conductance measured between opposite faces of a centimetre cube, K, is called conductivity. Conductivity values areusually expressed in microsiemens/centimetre or in siemens/centimetre at a specified temperature, normally 25C.3.1.2 electrical resistivityresistivity, nthe a-c resistance in o
19、hms measured between opposite faces of a centimetre cube ofan aqueous solution at a specified temperature.NOTE 2The unit of electrical resistivity is ohm-centimetre. The actual resistance of the cell, Rx, is measured in ohms, and is directly proportionalto the length of the path, L (in cm), and inve
20、rsely proportional to the cross-sectional area, A (in cm 2):Rx 5RL/A3.1.2.1 DiscussionThe unit of electrical resistivity is ohm-centimetre. The actual resistance of the cell, Rx, is measured in ohms, and is directlyproportional to the length of the path, L (in cm), and inversely proportional to the
21、cross-sectional area, A (in cm2):Rx 5RL/AThe resistance measured between opposite faces of a centimetre cube, R, is called resistivity. Resistivity values are usuallyexpressed in ohmcentimetre, or in megohm centimetre, at a specified temperature, normally 25C.The resistance measured between opposite
22、 faces of a centimetre cube, R, is called resistivity. Resistivity values are usuallyexpressed in ohmcentimetre, or in megohm centimetre, at a specified temperature, normally 25C.3.1.3 For definitions of other terms used in these methods, refer to Terminology D1129.3.2 Symbols:3.2.1 Symbols used in
23、the equations in Sections 14 and 16 are defined as follows:J = cell constant, cm cm1,K = conductivity at 25C, S/cm,Kx = measured conductance, S,K1 = conductivity of the KCl in the reference solution at the temperature of measurement (Table 1), S/cm,K2 = conductivity of the water used to prepare the
24、reference solution, at the same temperature of measurement, S/cm,Q = temperature correction factor (see Section 11),R = resistivity at 25C, ohm cm,Rx = measured resistance, ohm.4. Significance and Use4.1 These test methods are applicable for such purposes as impurity detection and, in some cases, th
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMD11252014STANDARDTESTMETHODSFORELECTRICALCONDUCTIVITYANDRESISTIVITYOFWATER 电导 电阻率 标准 试验 方法 PDF

链接地址:http://www.mydoc123.com/p-509302.html