ASTM C939 C939M-2016a Standard Test Method for Flow of Grout for Preplaced-Aggregate Concrete (Flow Cone Method)《预置骨料混凝土灌浆流动的标准试验方法 (流动锥法)》.pdf
《ASTM C939 C939M-2016a Standard Test Method for Flow of Grout for Preplaced-Aggregate Concrete (Flow Cone Method)《预置骨料混凝土灌浆流动的标准试验方法 (流动锥法)》.pdf》由会员分享,可在线阅读,更多相关《ASTM C939 C939M-2016a Standard Test Method for Flow of Grout for Preplaced-Aggregate Concrete (Flow Cone Method)《预置骨料混凝土灌浆流动的标准试验方法 (流动锥法)》.pdf(3页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: C939/C939M 16aStandard Test Method forFlow of Grout for Preplaced-Aggregate Concrete (Flow ConeMethod)1This standard is issued under the fixed designation C939/C939M; the number immediately following the designation indicates the yearof original adoption or, in the case of revision, the
2、 year of last revision. A number in parentheses indicates the year of last reapproval.A superscript epsilon () indicates an editorial change since the last revision or reapproval.This standard has been approved for use by agencies of the U.S. Department of Defense.1. Scope*1.1 This test method cover
3、s a procedure, used both in thelaboratory and in the field, for determining the time of efflux ofa specified volume of fluid hydraulic cement grout through astandardized flow cone and used for preplaced-aggregate (PA)concrete; however, the test method may also be used for otherfluid grouts.1.2 It is
4、 for use with neat grout and with grouts containingfine aggregate all passing a 2.36-mm (No. 8) sieve.1.3 This test method is intended for use with grout havingan efflux time of 35 s or less.1.4 When efflux time exceeds 35 s, flowability is betterdetermined by flow table, found in Test Method C109/C
5、109M,using 5 drops in 3 s.1.5 The values stated in either SI units or inch-pound unitsare to be regarded separately as standard. The values stated ineach system may not be exact equivalents; therefore, eachsystem shall be used independently of the other. Combiningvalues from the two systems may resu
6、lt in non-conformancewith the standard. Some values have only SI units because theinch-pound equivalents are not used in practice (Note 1).NOTE 1Sieve size is identified by its standard designation in Speci-fication E11. The alternative designation given in parentheses is forinformation only and doe
7、s not represent a different standard sieve size.1.6 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of reg
8、ulatory limitations prior to use.2. Referenced Documents2.1 ASTM Standards:2C109/C109M Test Method for Compressive Strength ofHydraulic Cement Mortars (Using 2-in. or 50-mm CubeSpecimens)C125 Terminology Relating to Concrete and Concrete Ag-gregatesC219 Terminology Relating to Hydraulic CementC938 P
9、ractice for Proportioning Grout Mixtures forPreplaced-Aggregate ConcreteE11 Specification for Woven Wire Test Sieve Cloth and TestSieves3. Terminology3.1 Definitions:3.1.1 For definitions of terms used in this test method, referto Terminologies C125 and C219.4. Summary of Test Method4.1 The time of
10、efflux of a specified volume of grout from astandardized flow cone is measured.5. Significance and Use5.1 This test method is applicable to the determination ofthe fluidity of various fluid grout mixtures.6. Interferences6.1 The presence of solid particles retained on the 2.36-mm(No. 8) sieve or lum
11、ps of unmixed material in the grout maycause the grout to flow unevenly through the discharge tube ofthe flow cone or stop the flow completely. Uneven flow willresult in slower transit of the grout, thereby indicating a falseconsistency.1This test method is under the jurisdiction of ASTM Committe C0
12、9 on Concreteand Concrete Aggregates and is the direct responsibility of Subcommittee C09.41on Hydraulic Cement Grouts.Current edition approved Aug. 1, 2016. Published October 2016. Originallyapproved in 1981. Last previous edition approved in 2016 as C939 16. DOI:10.1520/C0939-16A.2For referenced A
13、STM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.*A Summary of Changes section appears at the end of this standardCopyright AST
14、M International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States17. Apparatus7.1 Flow Cone, with dimensions as shown in Fig. 1. Thedischarge tube shall be stainless steel. The body can bestainless steel, cast aluminum, or other essentially non-corroding metal.NOTE
15、 2Cones with high-density polyethylene bodies are acceptablefor field use in situations where precision as described in this test methodis not required.7.2 Receiving Container, capacity 2000 mL, minimum.7.3 Ring Stand or other device, capable of supporting theflow cone in a vertical, steady position
16、 over the receivingcontainer.7.4 Level, carpenters or similar.7.5 Stop Watch, least reading of not more than 0.2 s.7.6 Grout Mixer, conforming to Practice C938 or as requiredby the specifier of the tests (See Note 3).NOTE 3The type of mixer used will impact the test results of a givengrout mixture.8
17、. Test Sample8.1 The grout test sample shall be in excess of 1725 mL andshall be representative of the grout in the mixer.8.2 When sampling and testing is being done for thepurpose of proportioning or comparing mixes or for qualifyingmaterials, the temperature of the dry materials and mixingwater sh
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMC939C939M2016ASTANDARDTESTMETHODFORFLOWOFGROUTFORPREPLACEDAGGREGATECONCRETEFLOWCONEMETHOD 预置 骨料 混凝土

链接地址:http://www.mydoc123.com/p-508887.html