ASTM C878 C878M-2003 Standard Test Method for Restrained Expansion of Shrinkage-Compensating Concrete.pdf
《ASTM C878 C878M-2003 Standard Test Method for Restrained Expansion of Shrinkage-Compensating Concrete.pdf》由会员分享,可在线阅读,更多相关《ASTM C878 C878M-2003 Standard Test Method for Restrained Expansion of Shrinkage-Compensating Concrete.pdf(5页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: C 878/C 878M 03Standard Test Method forRestrained Expansion of Shrinkage-CompensatingConcrete1This standard is issued under the fixed designation C 878/C 878M; the number immediately following the designation indicates the yearof original adoption or, in the case of revision, the year o
2、f last revision. A number in parentheses indicates the year of last reapproval.A superscript epsilon (e) indicates an editorial change since the last revision or reapproval.1. Scope1.1 This test method covers the determination of the expan-sion of concrete made with shrinkage-compensating cement.1.2
3、 The values stated in either SI units or inch-pound unitsare to be regarded separately as standard. The values stated ineach system may not be exact equivalents; therefore, eachsystem shall be used independently of the other. Combiningvalues from the two systems may result in non-conformancewith the
4、 standard.1.3 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use.2. Re
5、ferenced Documents2.1 ASTM Standards:C 125 Terminology Relating to Concrete and ConcreteAggregates2C 157/C 157M Test Method for Length Change of Hard-ened Hydraulic Cement, Mortar, and Concrete2C 192/C 192M Practice for Making and Curing ConcreteTest Specimens in the Laboratory2C 219 Terminology Rel
6、ating to Hydraulic Cement3C 403/C 403M Test Method for Time of Setting of ConcreteMixtures by Penetration Resistance2C 490 Practice for Use of Apparatus for the Determinationof Length Change of Hardened Cement Paste, Mortar, andConcrete3C 670 Practice for Preparing Precision and Bias Statementsfor T
7、est Methods for Construction Materials2C 806 Test Method for Restrained Expansion of ExpansiveCement Mortar3C 845 Specification for Expansive Hydraulic Cement32.2 ACI Standards and Committee Reports:4116-R-90 Cement and Concrete Terminology223-83 Standard Practice for the Use of Shrinkage-Compensati
8、ng Concrete3. Terminology3.1 Terms used in this test method are defined in Terminol-ogy C 219, Terminology C 125, and ACI 116-R-90.4. Significance and Use4.1 Since the potential for expansion, under conditions ofcontrolled restraint, of concrete made with shrinkage-compensating cement cannot always
9、be satisfactorily predictedfrom tests of mortars made in accordance with Test MethodC 806, a need has been recognized for a test method in whichconcrete specimens are tested.4.2 This test method can also be adapted readily to studiesof expansion involving degrees of restraint, comparisons ofcements,
10、 effects of cement contents, mixture proportions,schedules, or environmental treatments that differ from thestandard procedures prescribed by this test method.5. Apparatus5.1 Molds, for casting test specimens, when used in con-junction with the restraining cage described in 4.2, shallprovide for for
11、ming prisms 76 mm 3 in. square with a gagelength of 250 mm 10 in. The molds shall otherwise conformto the requirements for molds in Practice C 490, except that thestud holder, gage studs, and spacer screws described in thatpractice will not be used.5.2 Restraining Cage, consisting of a threaded low-
12、carbonsteel rod (plain or zinc-coated) with steel end plates held inplace by hex nuts as shown in Fig. 1. The hex nuts outside thecage shall be of stainless steel. Stainless steel cap nuts shall beput on each end of the rod. When tested in tension, within theelastic range, the rod shall have a strai
13、n of 2800 kN 0.0012 60.0001/630 lbf of load (Note 1).NOTE 1It is intended that all rods used meet the indicated requirement1This method is under the jurisdiction of ASTM Committee C09 on Concreteand Concrete Aggregates and is the direct responsibility of SubcommitteeC09.68 on Volume Change.Current e
14、dition approved Jan. 10, 2003. Published April 2003. Originallyapproved in 1978. Last previous edition approved in 1995 as C 87895a.2Annual Book of ASTM Standards, Vol 04.02.3Annual Book of ASTM Standards, Vol 04.01.4Available from American Concrete Institute (ACI), P.O. Box 9094, FarmingtonHills, M
15、I 48333.1Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.for strain. When a large number of rods are obtained as a single lot,exercise judgment as to whether or not all must be tested. The designation“10-24” is used in ordinary rods h
16、aving the desired properties.5.3 Length Comparator, conforming to and to be used inaccordance with the requirements of Practice C 490. Use areference bar complying with the description given in PracticeC 490. If the terminals of the comparator are fitted with collars,they shall be such that the cap
17、nuts on the ends of the threadedrod of the specimen do not rest on the collar during themeasuring (see Figs. 2 and 3).5.4 Tamping RodThe tamping rod shall be a straight steelrod, 10 mm 38in. in diameter, and no less than 250 mm 10in. in length, having at least the tamping end rounded to ahemispheric
18、al tip of the same diameter.5.5 Vibrators, conforming to the requirements for externalvibrators prescribed in Practice C 192/C 192M.6. Test Specimen6.1 The test specimen shall be a prism: 75 mm 3 in. squarewith a gage length of 250 mm 10 in. and an overall length(including the length of the rod and
19、cap nuts) of approximately290 mm 11.5 in. At least three specimens shall be preparedfor each test.MeasurementDimensionsin. mmA119166116 294 6 1.6B 10 254 (gage length)C3 7D231326132 75 6 1E112 38F13164 37.7G38 10H316 5NOTE 1All material is mild steel, except for stainless steel cap nuts.FIG. 1 Restr
20、aining CageC 878/C 878M 032NOTE 2Use of aggregates of nominal maximum size greater than 25.0mm 1 in. may adversely affect the test results.7. Preparation and Assembly of Specimen Molds andRestaining Cage7.1 Install the cap nuts firmly in place on the ends of therestraining rods using a suitable adhe
21、sive to keep them fromloosening when comparator readings are made (Note 3). Thecap nuts should not be removed after the initial comparatorreading of a specimen is made. Measure the restraining cageassembly length, including the cap nuts, while it is at 23.0 62C 73.5 6 3.5F. This is to ensure it is 3
22、0 6 2mm119166116 in. The measurement taken at this time is used only toensure that comparator readings can be made.NOTE 3A rapid-setting epoxy has been found suitable.7.2 Thinly cover the edges of the restraining cage end platesthat contact the sides and bottom of the mold with a heavymineral oil or
23、 light cup grease such as petrolatum. Afterassembly of the molds, place a restraining cage in each moldcompartment. Seal the contact lines between the outer sidesand base plate of the molds with paraffin or micro-crystallinewax. Thinly cover the interior faces of the molds with mineraloil and remove
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMC878C878M2003STANDARDTESTMETHODFORRESTRAINEDEXPANSIONOFSHRINKAGECOMPENSATINGCONCRETEPDF

链接地址:http://www.mydoc123.com/p-508634.html