ASTM C697-2016 Standard Test Methods for Chemical Mass Spectrometric and Spectrochemical Analysis of Nuclear-Grade Plutonium Dioxide Powders and Pellets《核级二氧化钚粉末和颗粒的化学 质谱和光谱分析的标准试验.pdf
《ASTM C697-2016 Standard Test Methods for Chemical Mass Spectrometric and Spectrochemical Analysis of Nuclear-Grade Plutonium Dioxide Powders and Pellets《核级二氧化钚粉末和颗粒的化学 质谱和光谱分析的标准试验.pdf》由会员分享,可在线阅读,更多相关《ASTM C697-2016 Standard Test Methods for Chemical Mass Spectrometric and Spectrochemical Analysis of Nuclear-Grade Plutonium Dioxide Powders and Pellets《核级二氧化钚粉末和颗粒的化学 质谱和光谱分析的标准试验.pdf(25页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: C697 16Standard Test Methods forChemical, Mass Spectrometric, and SpectrochemicalAnalysis of Nuclear-Grade Plutonium Dioxide Powders andPellets1This standard is issued under the fixed designation C697; the number immediately following the designation indicates the year oforiginal adopti
2、on or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope1.1 These test methods cover procedures for the chemical,mass spectrometric, a
3、nd spectrochemical analysis of nuclear-grade plutonium dioxide powders and pellets to determinecompliance with specifications.1.2 The analytical procedures appear in the following order:SectionsPlutonium Sample Handling 8 to 10Plutonium by Controlled-Potential Coulometry2Plutonium by Ceric Sulfate T
4、itration3Plutonium by Amperometric Titration with Iron(II)2Plutonium by Diode Array Spectrophotometry3Nitrogen by Distillation Spectrophotometry Using NesslerReagent11 to 18Carbon (Total) by Direct CombustionThermal Conductivity 19 to 29Total Chlorine and Fluorine by Pyrohydrolysis 30 to 37Sulfur by
5、 Distillation Spectrophotometry 38 to 46Plutonium Isotopic Analysis by Mass Spectrometry4Rare Earth Elements by Spectroscopy 47 to 54Trace Elements by CarrierDistillation Spectroscopy 55 to 62(Alternative: Impurities by ICP-AES or ICP-MS)Impurity Elements by Spark-Source Mass Spectrography 63 to 69M
6、oisture by the Coulometric Electrolytic Moisture Analyzer 70 to 77Total Gas in Reactor-Grade Plutonium Dioxide Pellets5Plutonium-238 Isotopic Abundance by Alpha Spectrometry3Americium-241 in Plutonium by Gamma-Ray Spectrometry2Rare Earths By Copper Spark-Spectroscopy 78 to 87Plutonium Isotopic Analy
7、sis by Mass Spectrometry 88 to 96Oxygen-To-Metal Atom Ratio by Gravimetry 97 to 1041.3 The values stated in SI units are to be regarded asstandard. The values given in parentheses are for informationonly.1.4 This standard does not purport to address all of thesafety concerns, if any, associated with
8、 its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use. For specificprecautionary statements, see Sections 6, 16.2.5, 44.7, 51.9 and92.5.1.2. Referenced Documents2.1
9、ASTM Standards:6C757 Specification for Nuclear-Grade Plutonium DioxidePowder for Light Water ReactorsC852 Guide for Design Criteria for Plutonium GloveboxesC859 Terminology Relating to Nuclear MaterialsC1068 Guide for Qualification of Measurement Methods bya Laboratory Within the Nuclear IndustryC11
10、08 Test Method for Plutonium by Controlled-PotentialCoulometryC1165 Test Method for Determining Plutonium byControlled-Potential Coulometry in H2SO4at a PlatinumWorking ElectrodeC1168 Practice for Preparation and Dissolution of PlutoniumMaterials for AnalysisC1206 Test Method for Plutonium by Iron (
11、II)/Chromium(VI) Amperometric Titration (Withdrawn 2015)7C1233 Practice for Determining Equivalent Boron Contentsof Nuclear MaterialsC1235 Test Method for Plutonium by Titanium(III)/Cerium(IV) Titration (Withdrawn 2005)7C1268 Test Method for Quantitative Determination of241Am in Plutonium by Gamma-R
12、ay SpectrometryC1307 Test Method for Plutonium Assay by Plutonium (III)Diode Array SpectrophotometryC1415 Test Method for238Pu Isotopic Abundance By AlphaSpectrometryC1432 Test Method for Determination of Impurities inPlutonium: Acid Dissolution, Ion Exchange MatrixSeparation, and Inductively Couple
13、d Plasma-AtomicEmission Spectroscopic (ICP/AES) Analysis1These test methods are under the jurisdiction of ASTM Committee C26 onNuclear Fuel Cycle and are the direct responsibility of Subcommittee C26.05 onMethods of Test.Current edition approved June 1, 2016. Published July 2016. Originally approved
14、in 1972. Last previous edition approved in 2010 as C697 10. DOI: 10.1520/C0697-16.2Discontinued as of November 15, 1992.3Discontinued as of January 1, 2004.4Discontinued as of May 30, 1980.5Discontinued as of June 2016.6For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact A
15、STM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.7The last approved version of this historical standard is referenced onwww.astm.org.Copyright ASTM International, 100 Barr Harbor Drive, PO Bo
16、x C700, West Conshohocken, PA 19428-2959. United States1C1625 Test Method for Uranium and Plutonium Concentra-tions and Isotopic Abundances by Thermal IonizationMass SpectrometryC1637 Test Method for the Determination of Impurities inPlutonium Metal:Acid Digestion and Inductively CoupledPlasma-Mass
17、Spectroscopy (ICP-MS) AnalysisC1672 Test Method for Determination of Uranium or Pluto-nium Isotopic Composition or Concentration by the TotalEvaporation Method Using a Thermal Ionization MassSpectrometerD1193 Specification for Reagent WaterD4327 Test Method for Anions in Water by Suppressed IonChrom
18、atographyE60 Practice for Analysis of Metals, Ores, and RelatedMaterials by SpectrophotometryE115 Practice for Photographic Processing in Optical Emis-sion Spectrographic Analysis (Withdrawn 2002)7E116 Practice for Photographic Photometry in Spectro-chemical Analysis (Withdrawn 2002)7E130 Practice f
19、or Designation of Shapes and Sizes ofGraphite Electrodes (Withdrawn 2013)73. Terminology3.1 Except as otherwise defined herein, definitions of termsare as given in Terminology C859.4. Significance and Use4.1 Plutonium dioxide is used in mixtures with uraniumdioxide as a nuclear-reactor fuel. In orde
20、r to be suitable for thispurpose, the material must meet certain criteria for plutoniumcontent, isotopic composition, and impurity content. These testmethods are designed to show whether or not a given materialmeets the specifications for these items as described in Speci-fication C757.4.1.1 An assa
21、y is performed to determine whether thematerial has the minimum plutonium content specified on a dryweight basis.4.1.2 Determination of the isotopic content of the plutoniumin the plutonium dioxide powder is made to establish whetherthe effective fissile content is in compliance with the purchas-ers
22、 specifications.4.1.3 Impurity content is determined to ensure that themaximum concentration limit of certain impurity elements isnot exceeded. Determination of impurities is also required forcalculation of the equivalent boron content (EBC) as describedin Practice C1233.4.2 Fitness for Purpose of S
23、afeguards and Nuclear SafetyApplicationsMethods intended for use in safeguards andnuclear safety applications shall meet the requirements speci-fied by Guide C1068 for use in such applications.5. Reagents5.1 Purity of ReagentsReagent grade chemicals shall beused in all tests. Unless otherwise indica
24、ted, it is intended thatall reagents shall conform to the specifications of the Commit-tee on Analytical Reagents of the American Chemical Society,where such specifications are available.8Other grades may beused, provided it is first ascertained that the reagent is ofsufficiently high purity to perm
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMC6972016STANDARDTESTMETHODSFORCHEMICALMASSSPECTROMETRICANDSPECTROCHEMICALANALYSISOFNUCLEARGRADEPLUTONIUMDIOXIDEPOWDERSANDPELLETS

链接地址:http://www.mydoc123.com/p-508047.html