1、Designation: C1822 15Standard Specification forInsulating Covers on Accessible Lavatory Piping1This standard is issued under the fixed designation C1822; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the year of last revision. A
2、number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope1.1 This specification covers insulating covers for use onexposed drain and water supply piping under accessiblelavatories and sinks. The i
3、nsulating covers shall have thermalinsulating properties to protect people with disabilities fromburns and physical harm from contact with exposed watersupply and waste piping under accessible lavatories and sinks.Insulating covers shall be removable and reusable.1.2 Included are criteria for classi
4、fying removable andreusable protective covers on exposed drain and water supplypiping under lavatories and sinks and requirements and testmethods for materials and workmanship. Methods of markingare also given.1.3 The products covered by this specification are intendedfor use on water supply and dra
5、in or waste piping underlavatories and sinks only.1.4 The values stated in inch-pound units shall be regardedas the standard. The values given in parentheses are mathemati-cal conversions to SI units that are provided for informationonly and are not considered standard.1.5 This specification does no
6、t establish the criteria requiredin the design of the equipment over which removable insulat-ing covers are used, nor does this specification establish orrecommend the applicability of removable insulating coversover all surfaces.1.6 This standard does not apply to shrouds under lavatoriesand sinks.
7、1.7 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use.2. Referenced D
8、ocuments2.1 ASTM Standards:2C168 Terminology Relating to Thermal InsulationC177 Test Method for Steady-State Heat Flux Measure-ments and Thermal Transmission Properties by Means ofthe Guarded-Hot-Plate ApparatusC1045 Practice for Calculating Thermal Transmission Prop-erties Under Steady-State Condit
9、ionsD570 Test Method for Water Absorption of PlasticsD635 Test Method for Rate of Burning and/or Extent andTime of Burning of Plastics in a Horizontal PositionE84 Test Method for Surface Burning Characteristics ofBuilding MaterialsG21 Practice for Determining Resistance of Synthetic Poly-meric Mater
10、ials to Fungi2.2 Department of Justice Document:32010 Americans with Disabilities Act Standard for Acces-sible Design Section 606.52.3 ICC/ANSI Standard:4A117.1 Standard for Accessible and Usable Buildings andFacilities, Section 606.62.4 ASME Standard:5A112 18.9 Protectors/Insulators for Exposed Was
11、te and Sup-plies on Accessible Fixtures3. Terminology3.1 For definitions of terms used in this specification, referto Terminology C168.3.2 Definitions of Terms Specific to This Standard:1This specification is under the jurisdiction of ASTM Committee C16 onThermal Insulation and is the direct respons
12、ibility of Subcommittee C16.40 onInsulation Systems.Current edition approved Oct. 1, 2015. Published October 2015. DOI: 10.1520/C1822-15.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume i
13、nformation, refer to the standards Document Summary page onthe ASTM website.3Available from the U.S. Department of Justice, 950 Pennsylvania Ave., NWWashington, DC, 20530-0001, www.ada.gov.4Available from American National Standards Institute (ANSI), 25 W. 43rd St.,4th Floor, New York, NY 10036, htt
14、p:/www.ansi.org.5Available from American Society of Mechanical Engineers (ASME), ASMEInternational Headquarters, Two Park Ave., New York, NY 10016-5990, http:/www.asme.org.Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States13.2.1 accessib
15、leable to be accessed or approached by awheelchair or by people with disabilities.3.2.2 accessible lavatory or sinklavatories or sinks in-stalled to provide access for wheelchairs and people withdisabilities.3.2.3 insulating covermaterial or assembly of materialsthat is applied over piping to provid
16、e thermal protection fromhot and cold temperatures, and physical protection frombruising, abrasion, and cutting from sharp, hard, or abrasivesurfaces.3.2.4 lavatorya fixed washbasin used for personal hygienethat requires a water supply and discharges wastewater to thedrainage systems.3.2.5 removable
17、 and reusablean insulating cover whichcan be installed and then removed and reinstalled for mainte-nance and cleaning.3.2.6 shroudsa cover under a lavatory or sink that isattached to a cabinet or wall and not to piping.3.2.7 sinka fixed bowl or basin for general uses thatrequires a water supply and
18、discharges wastewater to thedrainage system.3.2.8 tepid waterdomestic water with temperature be-tween 60 to 100F (15.6 to 37.8C).3.2.9 waste pipingpiping and pipe fittings under lavatoriesor sinks that drain waste water.3.2.10 water supplypiping and pipe fitting that distributespotable water to a la
19、vatory or sink.4. Significance and Use4.1 Accessibility design standards require water suppliesand drain pipes under lavatories and sink are to be insulated orotherwise configured to protect people with disabilities fromcontact with exposed pipes. No sharp or abrasive surfaces areallowed under lavat
20、ories or sinks.4.2 People in wheelchairs and people with physical disabili-ties are part of the most at risk group for scalding, severereaction, bruising and cuts from exposed piping under lavato-ries and sinks. These groups, which also include youngchildren, the elderly, and the infirm sometimes re
21、quire differentsafety regulation due to but not limited to slower reaction time,physical disabilities, mobility impairments; and medical con-ditions which can increase exposure contact time and increasedvulnerability to severe reaction, discomfort, burns, bruises,abrasions, and cuts of the skin.4.3
22、This specification is intended to cover products whichwill satisfy the requirements of theAmericans with DisabilitiesAct 4.19.4, the Department of Justice: 2010 Americans withDisabilities Act Standard for Accessible Design Section 606.5,ICC/ANSI A117.1 2012 (Standard for Accessible and UsableBuildin
23、gs and Facilities - for Persons with Physical Disabili-ties) section 606.6 (Exposed Pipes and Surfaces).5. Classification5.1 Removable and reusable insulating covers covered bythis specification are classified into four types based upon thefire performance as follows:5.1.1 Type ITest Method E84 Flam
24、e spread/smoke devel-oped indices of 25/450.5.1.2 Type IITest Method E84 Flame spread/smoke devel-oped indices of 200/450.5.1.3 Type IIITest Method D635 Rate of Burning, maxi-mum 1 in. (25 mm).5.1.4 Type IVNo fire performance determined or required.6. Materials and Manufacture6.1 Insulating cover ma
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMC18222015STANDARDSPECIFICATIONFORINSULATINGCOVERSONACCESSIBLELAVATORYPIPING 使用 盥洗室 绝缘 标准 规格 PDF

链接地址:http://www.mydoc123.com/p-465889.html