1、Designation: C1713 15C1713 17Standard Specification forMortars for the Repair of Historic Masonry1This standard is issued under the fixed designation C1713; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the year of last revision.
2、 A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope1.1 This specification covers mortar for the repair of masonry that was constructed with methods and materials that pre-date theoriginat
3、ion of current standards of construction that are compatible with it. The mortar may be used for non-structural purposessuch as repointing of the masonry, or for structural purposes such as, but not restricted to, re-construction or repair of mortar jointsthat contribute to the structural integrity
4、of the masonry.1.2 Masonry includes the following units laid in mortar: (1) cast stone, (2) clay masonry unitsbrick and clay tile, (3) concretemasonry units, (4) natural stone, and (5) terra cotta.1.3 This specification may be used to pre-qualify mortar for a project.1.4 Mortars tested using this sp
5、ecification are laboratory-prepared mortars and do not represent in-place, site mortars.1.5 Use of this specification should be based on a thorough understanding of the function, maintenance, and repair requirementsfor the preservation and continued performance of the masonry in the context of the b
6、uilding structure and long-term performance.The user of this specification is responsible for examining all criteria and selecting the appropriate mortar formulation andproperties required.1.6 The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are m
7、athematicalconversions to SI units that are provided for information only and are not considered standard.1.7 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibilityof the user of this standard to establish appropriate safety an
8、d health practices and determine the applicability of regulatorylimitations prior to use.1.8 This international standard was developed in accordance with internationally recognized principles on standardizationestablished in the Decision on Principles for the Development of International Standards,
9、Guides and Recommendations issuedby the World Trade Organization Technical Barriers to Trade (TBT) Committee.2. Referenced Documents2.1 ASTM Standards:2C5 Specification for Quicklime for Structural PurposesC10 Specification for Natural CementC61 Specification for Gypsum Keenes CementC91 Specificatio
10、n for Masonry CementC109/C109M Test Method for Compressive Strength of Hydraulic Cement Mortars (Using 2-in. or 50-mm Cube Specimens)C110 Test Methods for Physical Testing of Quicklime, Hydrated Lime, and LimestoneC136 Test Method for Sieve Analysis of Fine and Coarse AggregatesC141 Specification fo
11、r Hydraulic Hydrated Lime for Structural PurposesC144 Specification for Aggregate for Masonry MortarC150 Specification for Portland CementC207 Specification for Hydrated Lime for Masonry PurposesC216 Specification for Facing Brick (Solid Masonry Units Made from Clay or Shale)1 This specification is
12、under the jurisdiction of ASTM Committee C12 on Mortars and Grouts for Unit Masonry and is the direct responsibility of Subcommittee C12.03on Specifications for Mortars.Current edition approved Dec. 1, 2015June 1, 2017. Published January 2016July 2017. Originally approved in 2010. Last previous edit
13、ion approved in 20122015 asC1713 12.C1713 15. DOI: 10.1520/C171315.10.1520/C171317.2 For referencedASTM standards, visit theASTM website, www.astm.org, or contactASTM Customer Service at serviceastm.org. For Annual Book of ASTM Standardsvolume information, refer to the standards Document Summary pag
14、e on the ASTM website.This document is not an ASTM standard and is intended only to provide the user of an ASTM standard an indication of what changes have been made to the previous version. Becauseit may not be technically possible to adequately depict all changes accurately, ASTM recommends that u
15、sers consult prior editions as appropriate. In all cases only the current versionof the standard as published by ASTM is to be considered the official document.Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States1C270 Specification for Mor
16、tar for Unit MasonryC305 Practice for Mechanical Mixing of Hydraulic Cement Pastes and Mortars of Plastic ConsistencyC511 Specification for Mixing Rooms, Moist Cabinets, Moist Rooms, and Water Storage Tanks Used in the Testing of HydraulicCements and ConcretesC595 Specification for Blended Hydraulic
17、 CementsC780 Test Method for Preconstruction and Construction Evaluation of Mortars for Plain and Reinforced Unit MasonryC948 Test Method for Dry and Wet Bulk Density, Water Absorption, and Apparent Porosity of Thin Sections of Glass-FiberReinforced ConcreteC979 Specification for Pigments for Integr
18、ally Colored ConcreteC1072 Test Methods for Measurement of Masonry Flexural Bond StrengthC1093 Practice for Accreditation of Testing Agencies for MasonryC1157 Performance Specification for Hydraulic CementC1180 Terminology of Mortar and Grout for Unit MasonryC1329 Specification for Mortar CementC138
19、4 Specification for Admixtures for Masonry MortarsC1400 Guide for Reduction of Efflorescence Potential in New Masonry WallsC1403 Test Method for Rate of Water Absorption of Masonry MortarsC1489 Specification for Lime Putty for Structural PurposesC1506 Test Method for Water Retention of Hydraulic Cem
20、ent-Based Mortars and PlastersC1707 Specification for Pozzolanic Hydraulic Lime for Structural PurposesE96/E96M Test Methods for Water Vapor Transmission of MaterialsE2260 Guide for Repointing (Tuckpointing) Historic Masonry3. Terminology3.1 The terms used in this specification are identified in Ter
21、minology C1180.3.2 Definitions of Terms Specific to This Standard:3.2.1 aggregate, nmaterial as defined in Terminology C1180, but limited to the material groups listed under Section 4 of thisspecification.3.2.2 binder, nmaterial as defined in Terminology C1180, but limited to the cementitious materi
22、al groups listed under Section4 of this specification to be mixed with potable water.3.2.3 curing, nprocess by which a mortar gains its long-term, final-state properties.3.2.4 curing time (CT), nnumber of days in which a hardened state sample is cured before testing.3.2.5 historic masonry, nmasonry
23、that may have been constructed with methods and materials that pre-date the originationof current standards.3.3 Properties, as determined by Section 8 of this specification:3.3.1 absorption rate (AR), na measure of the hardened mortars ability to absorb water from a dry condition, measured asthe ini
24、tial flow of water into the mortar, as defined under Test Method C1403 and evaluated at the specified curing time (CT).3.3.2 air content, ncumulative volume of air in a mortar, as a percentage of the total volume of mortar in its plastic state.3.3.3 flexural bond strength (FBS), nmaximum flexural te
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMC17132017STANDARDSPECIFICATIONFORMORTARSFORTHEREPAIROFHISTORICMASONRY 古迹 修复 灰浆 标准 规格 PDF

链接地址:http://www.mydoc123.com/p-465621.html