ASTM C1639-2016 Standard Specification for Fabrication Of Cellular Glass Pipe And Tubing Insulation《多孔玻璃管和管绝缘制造的标准规格》.pdf
《ASTM C1639-2016 Standard Specification for Fabrication Of Cellular Glass Pipe And Tubing Insulation《多孔玻璃管和管绝缘制造的标准规格》.pdf》由会员分享,可在线阅读,更多相关《ASTM C1639-2016 Standard Specification for Fabrication Of Cellular Glass Pipe And Tubing Insulation《多孔玻璃管和管绝缘制造的标准规格》.pdf(4页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: C1639 16Standard Specification forFabrication Of Cellular Glass Pipe And Tubing Insulation1This standard is issued under the fixed designation C1639; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the year of last rev
2、ision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope1.1 This specification covers fabrication techniques forcellular glass block into billets to fabricate pipe and tubinginsulation.
3、All materials shall be in accordance with Specifi-cation C552.1.2 The purpose of this specification is to optimize thethermal performance of installed cellular glass insulationsystems. This is best achieved by limiting the number of joints,in particular through joints.1.3 The values stated in inch-p
4、ound units are to be regardedas standard. The values given in parentheses are mathematicalconversions to SI units that are provided for information onlyand are not considered standard.1.4 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is ther
5、esponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use.2. Referenced Documents2.1 ASTM Standards:2C168 Terminology Relating to Thermal InsulationC450 Practice for Fabrication of Thermal
6、Insulating FittingCovers for NPS Piping, and Vessel LaggingC552 Specification for Cellular Glass Thermal InsulationC585 Practice for Inner and Outer Diameters of ThermalInsulation for Nominal Sizes of Pipe and TubingD312 Specification for Asphalt Used in Roofing2.2 ASTM Adjuncts:3ADJC0450A ASTM Reco
7、mmended Dimensional Standardsfor Fabrication of Thermal Insulation Fitting Covers3. Terminology3.1 Terminology C168 shall be considered as applying tothe terms in this specification.3.2 Definitions of Terms Specific to This Standard:3.2.1 billet / buna single piece of insulation made up froma number
8、 of smaller blocks held together with an adhesive.3.2.2 lagspieces of insulation typically curved or taperedused for insulating pipes, tanks and other cylindrical equip-ment.3.2.3 precision cut V-grooved pipe insulation, nrigid in-sulation pieces cut into 4-sided polygons, of two parallelsurfaces an
9、d two non-parallel surfaces of equal angles = 180/ N, such that when N number of these sections are assembled,they form an approximate circle and can be installed around apipe.3.2.3.1 DiscussionThe adjective precision refers to thefact that when these N sections are installed onto a pipe, theyfit ex
10、actly with no appreciable gaps between sections.3.2.4 bond joint, nthe joint formed by the adhered matingsurfaces of several thicknesses of cellular glass block orfabricated cellular glass insulation pieces that are used to createa cellular glass insulation billet, bun, or pipe and tubinginsulation
11、segments. See Fig. 1.3.2.4.1 DiscussionA bond joint is created during thefabrication of cellular glass pipe and tubing insulation and ismade with a full depth (100 % coverage) of an approvedadhesive. (See 3.2.1 and 8.4).3.2.5 fabrication joints see bond joint, nthe joint be-tween adhered mating surf
12、aces of cellular glass pipe and tubinginsulation segments formed by fabricated segments or sectionsof cellular glass insulation that are assembled in the fabricationshop, facility, or jobsite, to produce the cellular glass pipe andtubing insulation. See Figs. 2-4.3.2.5.1 DiscussionA fabrication join
13、t is created at a fab-rication shop or facility and is made with a full depth (100 %coverage) of an approved adhesive.3.2.6 field joints, nmating surfaces of cellular glass insu-lation created during the installation process.3.2.6.1 DiscussionField joints shall be formed with fulldepth adhesive, ful
14、l depth of sealant or from the matingsurfaces of the cellular glass insulation.1This specification is under the jurisdiction of ASTM Committee C16 onThermal Insulation and is the direct responsibility of Subcommittee C16.40 onInsulation Systems.Current edition approved Sept. 1, 2016. Published Octob
15、er 2016. Originallyapproved in 2007. Last previous edition approved in 2010 as C1639 10a. DOI:10.1520/C1639-16.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the s
16、tandards Document Summary page onthe ASTM website.3Available from ASTM International Headquarters. Order Adjunct No.ADJC0450A.Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States13.2.7 non-through joints, nbond or fabrication joints thatst
17、art at the outside circumference of fabricated insulation andrun continuously in a straight line to the opposite sideterminating at the outside circumference of the pipe insulation.(See Fig. 2.)3.2.7.1 DiscussionNon-through joints do not intersect thepipe insulations inside diameter (ID).3.2.8 throu
18、gh joints, nbond or fabrication joints that startat the outside circumference of fabricated insulation and runcontinuously in a straight line through the fabricated piece andterminates at the pipe insulations inside diameter (ID) (SeeFig. 3.)3.2.8.1 DiscussionThrough joints intersect the pipe/insula
19、tion interface.3.2.9 beveled lag, nrigid insulation pieces cut into isosce-les trapezoid shape used to form a 360 circle that is installedaround pipe or tubing.3.2.9.1 DiscussionBeveled lags differ from precision cutV-grooved in that pieces are a minimum of 8 in. (203 mm)wide and are not bonded to a
20、 scrim, fabric or jacketing.4. Classification4.1 Specification C552 defines Type I and Type II materials.The same classifications shall be used in this standard.5. Workmanship, Finish, and Appearance5.1 The insulation shall have no visible defects that willadversely affect its performance.6. Standar
21、d Sizes, Dimensions, and FabricationConfigurations of Cellular Glass Pipe and TubingInsulation6.1 Cellular glass pipe and tubing insulation shall be fabri-cated in lengths as agreed to by the purchaser and the supplier.Typical lengths are 2312 in. (597 mm), 2358 in. (600 mm), 24in. (610 mm), 3512 in
22、. (902 mm), or 36 in. (914 mm).6.2 Cellular glass pipe and tubing insulation with outerdiameters that are 658 in. (168 mm) shall be made to aminimum thickness of 1-in. (25 mm). Pipe insulation withouter diameter that is 658 in. (168 mm) shall be made to aminimum 112-in. (38 mm) thickness. Sizes shal
23、l conform toPractice C585.6.3 Cellular glass pipe insulation with outer diameters thatare 30 in. (762 mm) shall be furnished as curved sidewallsegments (see Fig. 5) which shall be fabricated in equal sizesegments such that no additional field cuts are required.6.6 For operating temperatures above am
24、bient, circular cutsegmented fabrication as shown in Fig. 5, beveled lags, orprecision cut V-grooved pipe insulation, as shown in Fig. 6,specifically cut to fit the required diameter, are acceptablealternatives.FIG. 1 Cellular Glass Insulation BilletFIG. 2 Non-through JointsFIG. 3 Through JointsFIG.
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMC16392016STANDARDSPECIFICATIONFORFABRICATIONOFCELLULARGLASSPIPEANDTUBINGINSULATION 多孔 玻璃管 绝缘 制造 标准

链接地址:http://www.mydoc123.com/p-465384.html