ACI ITG-7M-2009 Specification for Tolerances for Precast Concrete (Incorporates Errata November 13 2017)《预制混凝土公差规范》.pdf
《ACI ITG-7M-2009 Specification for Tolerances for Precast Concrete (Incorporates Errata November 13 2017)《预制混凝土公差规范》.pdf》由会员分享,可在线阅读,更多相关《ACI ITG-7M-2009 Specification for Tolerances for Precast Concrete (Incorporates Errata November 13 2017)《预制混凝土公差规范》.pdf(41页珍藏版)》请在麦多课文档分享上搜索。
1、ACI ITG-7M-09Specification for Tolerancesfor Precast ConcreteAn ACI StandardReported by ACI Innovation Task Group 7American Concrete InstituteAdvancing concrete knowledgeSpecification for Tolerances for Precast ConcreteFirst printingNovember 2009ISBN 978-0-87031-355-4Copyright by the American Concre
2、te Institute, Farmington Hills, MI. All rights reserved. This materialmay not be reproduced or copied, in whole or part, in any printed, mechanical, electronic, film, or otherdistribution and storage media, without the written consent of ACI.The technical committees responsible for ACI committee rep
3、orts and standards strive to avoid ambiguities,omissions, and errors in these documents. In spite of these efforts, the users of ACI documents occasionallyfind information or requirements that may be subject to more than one interpretation or may beincomplete or incorrect. Users who have suggestions
4、 for the improvement of ACI documents arerequested to contact ACI. Proper use of this document includes periodically checking for errata atwww.concrete.org/committees/errata.asp for the most up-to-date revisions.ACI committee documents are intended for the use of individuals who are competent to eva
5、luate thesignificance and limitations of its content and recommendations and who will accept responsibility for theapplication of the material it contains. Individuals who use this publication in any way assume all risk andaccept total responsibility for the application and use of this information.A
6、ll information in this publication is provided “as is” without warranty of any kind, either express or implied,including but not limited to, the implied warranties of merchantability, fitness for a particular purpose ornon-infringement.ACI and its members disclaim liability for damages of any kind,
7、including any special, indirect, incidental,or consequential damages, including without limitation, lost revenues or lost profits, which may resultfrom the use of this publication.It is the responsibility of the user of this document to establish health and safety practices appropriate tothe specifi
8、c circumstances involved with its use. ACI does not make any representations with regard tohealth and safety issues and the use of this document. The user must determine the applicability of allregulatory limitations before applying the document and must comply with all applicable laws and regulatio
9、ns,including but not limited to, United States Occupational Safety and Health Administration (OSHA) healthand safety standards.Order information: ACI documents are available in print, by download, on CD-ROM, through electronicsubscription, or reprint and may be obtained by contacting ACI.Most ACI st
10、andards and committee reports are gathered together in the annually revised ACI Manual ofConcrete Practice (MCP).American Concrete Institute38800 Country Club DriveFarmington Hills, MI 48331U.S.A.Phone: 248-848-3700Fax: 248-848-3701www.concrete.orgACI ITG-7M-09 was adopted August 13, 2009, and publi
11、shed November 2009.Copyright 2009, American Concrete Institute.All rights reserved including rights of reproduction and use in any form or by anymeans, including the making of copies by any photo process, or by electronic ormechanical device, printed, written, or oral, or recording for sound or visu
12、al reproduc-tion or for use in any knowledge or retrieval system or device, unless permission inwriting is obtained from the copyright proprietors.ITG-7M-1Specification for Tolerances for Precast ConcreteAn ACI StandardReported by ACI Innovation Task Group 7ACI ITG-7M-09This Reference Specification
13、provides standard tolerances for precastconcrete construction. It covers dimensional tolerances for precastconcrete members used in building construction, and it covers erectiontolerances for these members. This document is intended to be adopted byreference in Contract Documents. The Specifier supp
14、lements the provi-sions of this Reference Specification as needed by specifying project-specific requirements in Contract Documents.Keywords: alignment; construction; erection tolerances; precast concrete;prestressed concrete; product tolerances; reinforcement; specification.CONTENTS(mandatory porti
15、on follows)Section 1General requirements, p. ITG-7M-21.1Scope1.2Requirements1.3Definitions1.4Referenced standardsSection 2Structural product tolerances,p. ITG-7M-52.1Scope2.2TolerancesSection 3Structural product erection tolerances, p. ITG-7M-213.1Scope3.2TolerancesSection 4Nonstructural architectur
16、al product tolerances, p. ITG-7M-294.1Scope4.2TolerancesSection 5Nonstructural architectural product erection tolerances, p. ITG-7M-355.1Scope5.2Tolerances(nonmandatory portion follows)Notes to Specifier, p. ITG-7M-37General notesForeword to checklists, p. ITG-7M-37Mandatory Requirements Checklist,
17、p. ITG-7M-37Optional Requirements Checklist, p. ITG-7M-37(mandatory portion follows)Charles S. HanskatChairNicholas J. Carino W. Calvin McCallNed M. Cleland David N. PetersonHarry A. Gleich Eldon G. TippingITG-7M-2 ACI STANDARDSECTION 1GENERAL REQUIREMENTS1.1Scope1.1.1 Work specifiedThis Specificati
18、on designatesstandard tolerances for structural and architectural precastconcrete members. Tolerances are provided for individualmembers and their erection. The indicated tolerances governunless otherwise specified.1.1.2 Work not specifiedInterface tolerances betweenprecast concrete members and cast
19、-in-place concreteconstruction are specified in ACI 117.1.1.3 UnitsValues in this specification are stated in SIunits. A companion specification in inch-pound units is alsoavailable.1.2Requirements1.2.1 Accumulation of tolerancesTolerances are notcumulative. Accumulations of individual tolerances on
20、 a singleitem shall not be used to increase an established tolerance.Individual tolerances are unique to their specific applicationand shall not be combined with other tolerances to form atolerance envelope. The most restrictive tolerance controls.1.2.2 Sign definitionPlus (+) tolerance increases th
21、edimension or elevation to which it applies. Minus () tolerancedecreases the dimension or elevation to which it applies.1.2.3 Exceeding tolerancesIf the product and erectiontolerances in this document are exceeded, the member or themodified assembly shall be accepted if the followingconditions are m
22、et:(a) The Licensed Design Professional determines thatthe structural requirements have been satisfied.(b) The Owner or Architect accepts the appearance ofexposed surfaces.1.3DefinitionsArchitect/Engineerthe architect, engineer, architecturalfirm, or engineering firm developing Contract Documents or
23、administering the Work under Contract Documents, or both.bearing width overhangdistance from the side ofprecast concrete member to side of bearing media, that is,pad or shim, measured perpendicular to the direction of thespan, as shown in Fig. 1.1.blockoutopening through the member for conduit,pipin
24、g, ductwork, connections, or structural framing.bowingthe deviation of the edge or surface of a planarwall member, in the out-of-plane direction, from a linepassing through any two corners of the member, as shown inFig. 1.2.camberdeviation of the bottom of the member from aline between the bottom en
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ACIITG7M2009SPECIFICATIONFORTOLERANCESFORPRECASTCONCRETEINCORPORATESERRATANOVEMBER132017 预制 混凝土 公差 规范

链接地址:http://www.mydoc123.com/p-401417.html