1、Designation: C1623 11C1623 16Standard Specification forManufactured Concrete Masonry Lintels1This standard is issued under the fixed designation C1623; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the year of last revision. A nu
2、mber in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope*1.1 This specification covers concrete masonry lintels (beams) that are solid in cross-section, are reinforced for flexure, and aremade from
3、 hydraulic cement, water, and mineral aggregates with or without the inclusion of other materials. These lintels aresuitable for both loadbearing and nonloadbearing applications.NOTE 1This specification covers only concrete masonry lintels containing reinforcement. Due to building code imposed limit
4、ations on the design ofmasonry lintels, all lintels must contain reinforcement. Concrete masonry lintels are not typically manufactured using shear reinforcement (stirrups orother vertical reinforcement). Therefore, this standard does not address issues related to such. For further guidance, refer t
5、o Building Code Requirementsfor Masonry Structures, TMS 402TMS 402.ACI 530ASCE 5. Prestressed concrete lintels are not covered by this standard.1.2 Lintels are manufactured using a no-slump concrete mix to provide a surface texture similar to that of concrete masonry.This specification applies to bo
6、th machine-made and hand-tamped concrete masonry lintels intended for use in concrete masonryapplications.1.3 Concrete masonry lintels covered by this specification are made from lightweight or normal weight aggregates, or both.1.4 This specification does not address the design or analysis of lintel
7、 capacity. Structural evaluations must be performedseparately. The strength of a lintel is a function of factors including, but not limited to, the characteristics of the materials usedin manufacturing (concrete materials and reinforcement), the amount and location of reinforcement, and the manufact
8、uring andcuring procedures. For design and analysis methods, refer to Building Code Requirements for Masonry Structures,TMS 402TMS 402.ACI 530ASCE 5.1.5 This specification does not cover U-shaped lintels or those of other cross-sections that are not 100 % solid.1.6 This specification does not cover
9、lintels of grouted concrete masonry lintels, or precast or cast-in-place lintels of slumpconcrete.1.7 The text of this standard references notes and footnotes that provide explanatory material. These notes and footnotes(excluding those in tables and figures) shall not be considered as requirements o
10、f the standard.1.8 The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematicalconversions to SI units that are provided for information only and are not considered standard.2. Referenced Documents2.1 ASTM Standards:2A615/A615M Specification
11、for Deformed and Plain Carbon-Steel Bars for Concrete ReinforcementA706/A706M Specification for Deformed and Plain Low-Alloy Steel Bars for Concrete ReinforcementA996/A996M Specification for Rail-Steel and Axle-Steel Deformed Bars for Concrete ReinforcementC33 Specification for Concrete AggregatesC1
12、40 Test Methods for Sampling and Testing Concrete Masonry Units and Related UnitsC150 Specification for Portland CementC331 Specification for Lightweight Aggregates for Concrete Masonry UnitsC595 Specification for Blended Hydraulic CementsC618 Specification for Coal Fly Ash and Raw or Calcined Natur
13、al Pozzolan for Use in Concrete1 This specification is under the jurisdiction of ASTM Committee C15 on Manufactured Masonry Units and is the direct responsibility of Subcommittee C15.03 onConcrete Masonry Units and Related Units.Current edition approved Dec. 15, 2011Dec. 15, 2016. Published January
14、2012January 2017. Originally approved in 2005. Last previous edition approved in 20062011as C1623 06.C1623 11. DOI: 10.1520/C1623-11.2 For referencedASTM standards, visit theASTM website, www.astm.org, or contactASTM Customer Service at serviceastm.org. For Annual Book of ASTM Standardsvolume inform
15、ation, refer to the standards Document Summary page on the ASTM website.This document is not an ASTM standard and is intended only to provide the user of an ASTM standard an indication of what changes have been made to the previous version. Becauseit may not be technically possible to adequately dep
16、ict all changes accurately, ASTM recommends that users consult prior editions as appropriate. In all cases only the current versionof the standard as published by ASTM is to be considered the official document.*A Summary of Changes section appears at the end of this standardCopyright ASTM Internatio
17、nal, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States1C979 Specification for Pigments for Integrally Colored ConcreteC989 Specification for Slag Cement for Use in Concrete and MortarsC1157 Performance Specification for Hydraulic CementC1232 Terminology of MasonryC1
18、240 Specification for Silica Fume Used in Cementitious MixturesC1262 Test Method for Evaluating the Freeze-Thaw Durability of Dry-Cast Segmental Retaining Wall Units and RelatedConcrete Units2.2 Other StandardsStandards:3TMS 402ACI 530ASCE 5 Building Code Requirements for Masonry StructuresTMS 602AC
19、I 530.1ASCE 6 Specification for Masonry Structures3. Terminology3.1 Terminology defined in Terminology C1232 shall apply for this specification.4. Material4.1 Cementitious MaterialsMaterials shall conform to the following applicable specifications: 4.1.1 Portland CementSpecification C150.4.1.1 Portl
20、and CementSpecification C150.4.1.2 Modified Portland CementPortland cement conforming to Specification C150, modified as follows:(1) Limestone If calcium carbonate is added to the cement, the CaCO3 content shall be not less than 85 %.(1) LimestoneIf calcium carbonate is added to the cement, the CaCO
21、3 content shall be not less than 85 %.(2) Limitation on Insoluble Residue1.5 %.(3) Limitation on Air Content of MortarVolume percent, 22 % max.(4) Limitation on Loss on Ignition7 %.(2) Limitation on Insoluble Residue1.5 %.(3) Limitation on Air Content of MortarVolume percent, 22 % max.(4) Limitation
22、 on Loss on Ignition7 %.4.1.3 Blended Hydraulic CementsSpecification C5954.1.4 Hydraulic CementSpecification C1157.4.1.5 PozzolansSpecification C618.4.1.6 Ground Granulated Blast Furnace SlagSpecification C989.4.1.7 Silica FumeSpecification C1240.4.2 AggregatesAggregates shall conform to the followi
23、ng specifications, except that grading requirements shall notnecessarily apply:4.2.1 Normal Weight AggregatesSpecification C33.4.2.2 Lightweight AggregatesSpecification C331.4.3 Pigments for Integrally Colored ConcreteSpecification C979.4.4 Steel ReinforcementSteel reinforcement shall consist of def
24、ormed bars conforming to Specifications A615/A615M,A706/A706M, or A996/A996M.4.5 Other ConstituentsAir-entraining agents, integral water repellents, and other constituents shall be previously establishedas suitable for use in concrete masonry lintels and shall conform to applicable ASTM standards or
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMC16232016STANDARDSPECIFICATIONFORMANUFACTUREDCONCRETEMASONRYLINTELSPDF

链接地址:http://www.mydoc123.com/p-465342.html