ASTM C1248-2008 Standard Test Method for Staining of Porous Substrate by Joint Sealants《用接缝密封胶着色多孔衬底的标准试验方法》.pdf
《ASTM C1248-2008 Standard Test Method for Staining of Porous Substrate by Joint Sealants《用接缝密封胶着色多孔衬底的标准试验方法》.pdf》由会员分享,可在线阅读,更多相关《ASTM C1248-2008 Standard Test Method for Staining of Porous Substrate by Joint Sealants《用接缝密封胶着色多孔衬底的标准试验方法》.pdf(4页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: C 1248 08Standard Test Method forStaining of Porous Substrate by Joint Sealants1This standard is issued under the fixed designation C 1248; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the year of last revision. A n
2、umber in parentheses indicates the year of last reapproval. Asuperscript epsilon (e) indicates an editorial change since the last revision or reapproval.1. Scope1.1 This test method covers four types of laboratory tests todetermine if a joint sealant has a probability of staining aporous substrate (
3、such as marble, limestone, sandstone, andgranite). The tests are on compressed samples and include (1)storage under standard laboratory conditions, (2) storage in anoven, and (3) exposure in a fluorescent UV/condensationdevice, and (4) exposure in a xenon arc device.1.2 The values stated in SI units
4、 are to be regarded as thestandard. The values given in parentheses are for informationonly.1.3 This standard does not purport to address all of thesafety problems, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health pract
5、ices and determine the applica-bility of regulatory limitations prior to use.1.4 The committee with jurisdiction over this standard is notaware of any comparable standards published by other orga-nizations.2. Referenced Documents2.1 ASTM Standards:2C 717 Terminology of Building Seals and SealantsC 1
6、442 Practice for Conducting Tests on Sealants UsingArtificial Weathering ApparatusG113 Terminology Relating to Natural and ArtificialWeathering Tests of Nonmetallic MaterialsG 151 Practice for Exposing Nonmetallic Materials in Ac-celerated Test Devices that Use Laboratory Light SourcesG 154 Practice
7、 for Operating Fluorescent Light Apparatusfor UV Exposure of Nonmetallic MaterialsG 155 Practice for Operating Xenon Arc Light Apparatusfor Exposure of Non-Metallic Materials3. Terminology3.1 Definitions:3.1.1 Refer to Terminology C 717 and G113for definitionsof terms used in this test method.4. Sum
8、mary of Test Method4.1 In this test method standard joint specimens are com-pressed and clamped at the manufacturers rated movementcapability and subjected to the following treatments; (a) four ofthe specimens are stored at standard conditions while undercompression for up to 28 days; (b) four of th
9、e specimens areexposed in an oven while under compression for up to 28 days;(c) four of the specimens are exposed either in a fluorescentUV/condensation device or in a xenon arc device while undercompression for up to 28 days.4.1.1 This test method allows for additional exposure be-yond the minimum
10、28 day exposure period as described in 4.1.If it is desired to extend the exposure period beyond 28 days,prepare an additional six specimens for each extended expo-sure period. Of these six specimens prepared, two specimenseach should be stored as described in the three conditionsnamed in 4.1.4.2 Th
11、e effects of the test are evaluated by visual inspectionfor changes in surface appearance and average measurementsof any stain depth and stain width.4.3 This test method is applicable to any type of elastomericjoint sealant and any type of porous substrate.5. Significance and Use5.1 Staining of buil
12、ding materials is an aesthetically unde-sirable occurrence. This test method evaluates the likelihood ofa sealant causing an early stain on a porous substrate due toexudation of materials from the sealant. Since this is anaccelerated test, it does not necessarily predict that the testedsealants will
13、 not stain or discolor porous substrates over longerperiods of time.6. Apparatus6.1 Forced-Draft Oven.6.2 Exposure Apparatus:6.2.1 Fluorescent UV/condensation apparatus that conformsto the requirements in Practices G 151 and G 154 with UVA-340 type lamps.1This test method is under the jurisdiction o
14、fASTM Committee C24 on BuildingSeals and Sealants and is the direct responsibility of Subcommittee C24.40 onWeathering.Current edition approved April 1, 2008. Published April 2008. Originallyapproved in 1993. Last previous edition approved in 2006 as C 1248-06.2For referenced ASTM standards, visit t
15、he ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.1Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959,
16、 United States.6.2.2 Xenon-Arc apparatus that conforms to the require-ments in Practices G 151 and G 155 with daylight type filters.6.3 TFE-Fluorocarbon Spacers.6.4 Masking Tape.7. Test Specimens7.1 Substrates shall be 25 by 25 by 75 mm (1 by 1 by 3 in.).A total of 24 substrates are required to make
17、 the twelve testspecimens.7.1.1 If testing beyond the minimum 28 day exposureperiod, prepare an additional twelve substrates to make the sixadditional test specimens as required in 4.1.1.NOTE 1The precision and bias statement is based on Vermont whitemarble and Bethel white granite substrates.7.2 Pr
18、imersWhen a primer is recommended by the seal-ant manufacturer, apply the primer to one substrate block ofeach test specimen. Apply the primer where the sealant will bein contact with the substrate.7.3 Preparation of Test Specimens:7.3.1 Standard conditions of temperature and relative hu-midity used
19、 throughout this test method are defined as 23 62C (73.4 6 3.6F) and 50 6 5 %, respectively.7.3.2 Multi-Component SealantsPrepare twelve testspecimens for each substrate that is to be used in the test. Aftermaintaining the unopened sample for at least 24 h at standardconditions, mix thoroughly for 5
20、 min at least 250 g of basecompound with the appropriate amount of curing agent. Applya bead of sealant 13 by 13 by 50 mm (12 by12 by 2 in.)between parallel 25 by 75 mm (1 by 3 in.) faces of substrates(see Fig. 1). Use appropriate spacers to form the proper sizebead. Use adhesive tape, rubber bands,
21、 or clamps to hold thetest specimen together before and after filling it with thesealant. In the case of a self leveling sealant, use masking orother suitable tape to retain the sealant. Use masking tape onthe top surface of substrates to prevent sealant from curing onthe finished surface. Remove th
22、e tape immediately followingfilling of the specimen joint cavity.7.3.3 Single-Component SealantsPrepare the specimensas described in 7.3.2 except that no mixing is required.Condition the sealed cartridge or bulk container at standardconditions for at least 24 h before use.8. Conditioning8.1 Cure spe
23、cimens for 21 days at standard conditions.Separate the TFE-fluorocarbon spacers from the sealant assoon as practical during the curing period without damagingthe sealant.NOTE 2The producer may request conditions other than standardconditions for the curing of single-component sealants provided they
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMC12482008STANDARDTESTMETHODFORSTAININGOFPOROUSSUBSTRATEBYJOINTSEALANTS 接缝 密封胶 着色 多孔 衬底 标准 试验 方法 PDF

链接地址:http://www.mydoc123.com/p-463911.html