《ASTM C1244-2011 Standard Test Method for Concrete Sewer Manholes by the Negative Air Pressure (Vacuum) Test Prior to Backfill《回填前使用负气压(真空)测试混凝土排水管检修孔的标准试验方法》.pdf》由会员分享,可在线阅读,更多相关《ASTM C1244-2011 Standard Test Method for Concrete Sewer Manholes by the Negative Air Pressure (Vacuum) Test Prior to Backfill《回填前使用负气压(真空)测试混凝土排水管检修孔的标准试验方法》.pdf(4页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: C1244 11Standard Test Method forConcrete Sewer Manholes by the Negative Air Pressure(Vacuum) Test Prior to Backfill1This standard is issued under the fixed designation C1244; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revis
2、ion, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope1.1 This test method covers procedures for testing precastconcrete manhole sections when using the vacuum
3、 test methodto demonstrate the integrity of the installed materials and theconstruction procedures. This test method is used for testingconcrete manhole sections utilizing mortar, mastic, or gasketedjoints.1.2 This test method is intended to be used as a preliminarytest to enable the installer to de
4、monstrate the condition of theconcrete manholes prior to backfill. Users are hereby cautionedthat misuse or misapplication of the test criteria containedherein can cause permanent damage to the system being tested.NOTE 1Vacuum test criteria presented in this test method are similarto those in genera
5、l use. The test and criteria have been widely andsuccessfully used in testing manholes.NOTE 2The user of this test method is advised that no correlation hasbeen found between vacuum (air) and hydrostatic tests.1.3 This test method is the companion to metric TestMethod C1244M; therefore, no SI equiva
6、lents are shown inthis test method.1.4 This standard does not purport to address all of thesafety problems, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limit
7、ations prior to use.2. Referenced Documents2.1 ASTM Standards:2C822 Terminology Relating to Concrete Pipe and RelatedProductsC924 Practice for Testing Concrete Pipe Sewer Lines byLow-Pressure Air Test MethodC969 Practice for Infiltration and Exfiltration AcceptanceTesting of Installed Precast Concre
8、te Pipe Sewer LinesC1244M Test Method for Concrete Sewer Manholes by theNegative Air Pressure (Vacuum) Test Prior to Backfill(Metric)3. Terminology3.1 For definitions of terms relating to manholes, seeTerminology C822.4. Summary of Practice4.1 All lift holes and any pipes entering the manhole are to
9、be plugged.Avacuum will be drawn and the vacuum drop overa specified time period is used to determine the acceptability ofthe manhole.5. Significance and Use5.1 This is not a routine test. The values recorded areapplicable only to the manhole being tested and at the time oftesting.6. Preparation of
10、the Manhole6.1 All lift holes shall be plugged.6.2 All pipes entering the manhole shall be temporarilyplugged, taking care to securely brace the pipes and plugs toprevent them from being drawn into the manhole.7. Procedure7.1 The test head shall be placed at the top of the manholein accordance with
11、the manufacturers recommendations.7.2 A vacuum of 10 in. Hg shall be drawn on the manhole,the valve on the vacuum line of the test head closed, and thevacuum pump shut off. The time shall be measured for thevacuum to drop to 9 in. Hg.1This test method is under the jurisdiction of ASTM Committee C13
12、onManholes and Specials.Current edition approved Nov. 1, 2011. Published November 2011. Originallyapproved in 1993. Last previous edition approved in 2005 as C1244 05a1. DOI:10.1520/C1244-11.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serv
13、iceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.1Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.7.3 The manhole is acceptable if the time for the vacuu
14、mreading to drop from 10 in. Hg to 9 in. Hg meets or exceeds thevalues indicated in Table 1.7.4 If the manhole fails the initial test, the manhole shall berepaired by an approved method until a satisfactory test isobtained.7.5 Use or failure of this vacuum test shall not precludeacceptance by approp
15、riate water infiltration or exfiltrationtesting, (see Practice C969), or other means.8. Precision and Bias8.1 No justifiable statement is presently capable of beingmade either on the precision or bias of this procedure, since thetest result merely states whether there is conformance to thecriteria f
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMC12442011STANDARDTESTMETHODFORCONCRETESEWERMANHOLESBYTHENEGATIVEAIRPRESSUREVACUUMTESTPRIORTOBACKFILL

链接地址:http://www.mydoc123.com/p-463896.html