《ASTM B78-1990(2007) Standard Test Method of Accelerated Life of Iron-Chromium-Aluminum Alloys for Electrical Heating《电加热用铁铬铝合金的加速寿命的试验方法》.pdf》由会员分享,可在线阅读,更多相关《ASTM B78-1990(2007) Standard Test Method of Accelerated Life of Iron-Chromium-Aluminum Alloys for Electrical Heating《电加热用铁铬铝合金的加速寿命的试验方法》.pdf(5页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: B 78 90 (Reapproved 2007)Standard Test Method ofAccelerated Life of Iron-Chromium-Aluminum Alloys forElectrical Heating1This standard is issued under the fixed designation B 78; the number immediately following the designation indicates the year of originaladoption or, in the case of re
2、vision, the year of last revision. A number in parentheses indicates the year of last reapproval. A superscriptepsilon (e) indicates an editorial change since the last revision or reapproval.1. Scope1.1 This test method covers the determination of the resis-tance to oxidation of iron-chromium-alumin
3、um electrical heat-ing alloys at elevated temperatures under intermittent heatingusing a constant-temperature cycle test. This test is used forinternal comparative purposes only.1.2 The values stated in inch-pound units are to be regardedas the standard. The metric equivalents of inch-pound unitsmay
4、 be approximate.1.3 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to become familiarwith all hazards including those identified in the appropriateMaterial Safety Data Sheet (MSDS) for this pr
5、oduct/materialas provided by the manufacturer, to establish appropriatesafety and health practices, and determine the applicability ofregulatory limitations prior to use.2. Significance and Use2.1 This test method is used by producers of electricalheating alloys to measure the cyclic oxidation resis
6、tance ofthese alloys.2.2 Because of the effect of environment, design and use,the life values obtained from this test method may not correlatewith that of an appliance or industrial heating unit.3. Test Panel3.1 Size and LocationThe dimensions of the test panelshall be similar to those shown in Fig.
7、 1. The test panel shall belocated in a position free from drafts of air.3.1.1 The enclosure shall fit tightly on the panel and theglass slide shall fit snugly to prevent leakage of air at this pointduring the operation of the test, as even a slight draft of air incontact with the specimen will caus
8、e excessive variation inlength of life. A screen of 40 wire mesh, 0.010-in. (0.025 mm)wire diameter, market grade, may be used as a cover over theindividual stations.3.2 TerminalsThe two terminals shall be spaced 2 in.(50.8 mm) apart, center to center and shall be so positioned thatthe wire specimen
9、 when secured therein shall be in a U-shapedpattern as described in Section 5. The specimen terminaljunctions shall be 3 in. (76.2 mm) lower than the plane of thetop of the enclosure.4. Apparatus4.1 The apparatus shall be similar to the requirementsspecified in 4.2 to 4.8, inclusive, and shall be co
10、nnected asshown in Fig. 2.4.2 Power SupplyThe transformer or motor generator setshall be capable of delivering a controlled voltage of from 10to 35 V to the circuit. It shall have a continuous currentcapacity of at least 20 A/specimen.4.3 Voltage ControlThe automatic voltage control shall becapable
11、of maintaining across the bus bars a constant voltagewithin 60.5 %.NOTE 1It has been found impossible to make accurate tests withoutvoltage control, as changes in line voltage are sufficient to causeconsiderable variation in the results obtained (see Annex A1).4.4 Variable TransformerThe variable tr
12、ansformer shallbe capable of adjusting the voltage across the specimen towithin approximately 0.25 % of any desired value within theworking range and shall have a continuous current rating ofapproximately 25 A.NOTE 2A variable transformer having a working range of adjustabil-ity from approximately 0
13、 to 20 V, provides for testing wires within aconsiderable range of size and resistivity.4.5 Ammeter and VoltmeterThe ammeter and voltmetershall have an accuracy of 1 % of normal test deflection(approximately 15 A and 15 V respectively). For alternatingcurrent the range shall be such as to give a rea
14、ding above thelower fifth of the scale range. The ammeter has appreciableresistance. A compensating resistance shall be cut into thecircuit to replace the resistance of the ammeter so that theover-all resistance of the circuit is not changed. This resistanceshall be inserted in series with the conta
15、ct of the upper switchshown in Fig. 2.4.6 Optical Pyrometer or Infrared ThermometerThe op-tical system shall be such as to provide a magnification of atleast four diameters. This may be accomplished by means of a1This test method is under the jurisdiction of ASTM Committee B02 onNonferrous Metals an
16、d Alloys and is the direct responsibility of SubcommitteeB02.10 on Thermostat Metals and Electrical Resistance Heating Materials.Current edition approved May 1, 2007. Published May 2007. Originallyapproved in 1959. Last previous edition approved in 2001 as B 78 90 (2001).1Copyright ASTM Internationa
17、l, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.special lens or combination of two standard lenses in theobjective to provide a short focal length and the desiredmagnification (seeAnnexA1). These instruments must have anaccuracy of 610F (5.5C) and UBS traceabil
18、ity.NOTE 3It is highly important that the temperatures of the testspecimen be adjusted as accurately as possible, as small variations intemperature result in considerable variation in length of life. Opticalpyrometer or infrared pycnometer makes it possible to determine thetemperature at any particu
19、lar point on the wire, and with the arrangementdescribed, the temperature of a comparatively small wire may be takenquite readily.4.7 InterrupterSome form of apparatus shall be used asan interrupter to open and close the circuit.4.8 Apparatus for Recording Time of BurnoutIf no appa-ratus is availabl
20、e for recording the time of burnout, arrange-ments shall be made for hourly observations for burnouts.5. Test Specimen5.1 The test specimen shall be 0.0254 in. (0.645 mm) indiameter. The length of the wire selected for test shall be suchas to give a test length of approximately 10 in. (254 mm).5.2 T
21、he test specimen shall be representative with regard tothe surface of the average of the coil or spool of wire which hasbeen selected for test. Particular care shall be taken to see thatthe specimen selected is free from kinks. This precaution isnecessary, since a kink, even though later removed may
22、 causeburnout at that point.NOTE 4It is also very desirable to select and keep as a referencestandard for comparison, a spool or coil of wire that is uniform in crosssection from one end to the other. Tests may then be made at any time onthe reference standard, and if conditions have changed they wi
23、ll be notedMetric Equivalentsin. mm12 12.75532 131.0714 184.22112 54622 55952 132164 1626FIG. 1 Test PanelB 78 90 (2007)2by the length of life of the standard. Comparisons between tests made atdifferent times on the standards and other wires may be correlated in thismanner (see Annex).6. Mounting Sp
24、ecimen6.1 A straight length of the specimen shall be shaped into a“U” pattern, 10 in. (254 mm) of which shall be mountedbetween the terminals described in 2.2. The “U” pattern shallconsist of two parallel legs and a semicircle of 1-in. (25.4-mm)radius, the plane of which is parallel to and equidista
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMB7819902007STANDARDTESTMETHODOFACCELERATEDLIFEOFIRONCHROMIUMALUMINUMALLOYSFORELECTRICALHEATING 加热

链接地址:http://www.mydoc123.com/p-462251.html