ASTM B286-2007 Standard Specification for Copper Conductors for Use in Hookup Wire for Electronic Equipment《电气设备连接线用铜导线的标准规范》.pdf
《ASTM B286-2007 Standard Specification for Copper Conductors for Use in Hookup Wire for Electronic Equipment《电气设备连接线用铜导线的标准规范》.pdf》由会员分享,可在线阅读,更多相关《ASTM B286-2007 Standard Specification for Copper Conductors for Use in Hookup Wire for Electronic Equipment《电气设备连接线用铜导线的标准规范》.pdf(5页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: B 286 07Standard Specification forCopper Conductors for Use in Hookup Wire for ElectronicEquipment1This standard is issued under the fixed designation B 286; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the year of
2、last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon (e) indicates an editorial change since the last revision or reapproval.This standard has been approved for use by agencies of the Department of Defense.1. Scope1.1 This specification covers uninsulate
3、d metallic-coatedcopper conductors for use in hookup wire for electronicequipment.1.2 The SI values for density are to be regarded as standard.For all other properties, the inch-pound values are to beregarded as the standard.2. Referenced Documents2.1 The following documents of the issue in effect o
4、n dateof material purchase form a part of this specification to theextent referenced herein:2.2 ASTM Standards:2B33 Specification for Tinned Soft or Annealed CopperWire for Electrical PurposesB 189 Specification for Lead-Coated and Lead-Alloy-Coated Soft Copper Wire for Electrical PurposesB 193 Test
5、 Method for Resistivity of Electrical ConductorMaterialsB 258 Specification for Nominal Diameters and Cross-Sectional Areas of AWG Sizes of Solid Round Wires Usedas Electrical ConductorsB 298 Specification for Silver-Coated Soft or AnnealedCopper WireB 355 Specification for Nickel-Coated Soft or Ann
6、ealedCopper Wire3. Ordering Information3.1 Orders for material under this specification shall includethe following information:3.1.1 Quantity of each size, designation (Table 1) and type,3.1.2 Conductor size, designation, construction, and type(Table 1).3.1.3 Whether tin, lead alloy, silver-coated,
7、or nickel-coated(see 4.1).3.1.4 For silver-coated conductors and nickel-coated con-ductors, class of coating (see 4.1), and when required, unan-nealed (see 4.2),3.1.5 Desired constructions where alternates are given(Table 1, Type II and, 5.1, 6.1, and 6.2),3.1.6 Package size (Section 12).3.1.7 Speci
8、al package marking if required (Section 11), and3.1.8 Place of inspection (Section 10).4. General Requirements4.1 Coating of WiresThe coating of the solid conductorsand the wires composing stranded conductors (before strand-ing) shall conform to the coating requirements of ASTMSpecifications B 33, B
9、 189, B 298, and B 355, as indicated onthe purchase order.4.2 TemperUnless otherwise specified, all coated conduc-tors shall be furnished in the annealed temper. When sospecified, silver-coated conductors or nickel-coated conductorsshall be furnished unannealed (Explanatory Note 1).NOTE 1The term un
10、annealed as used in this specification meanscold-worked conductor as produced on commercial wire-drawing ma-chines.4.3 ElongationThe elongation of annealed Type I conduc-tors shall be as specified in Specifications B 33, B 189, B 298,and B 355 as applicable. The elongation of stranded conductorsshal
11、l be permitted to vary from the requirements of theapplicable Specifications: B 33, B 189, B 298, and B 355 bythe following amounts:4.3.1 For stranded conductors 22 AWG and smaller, the testshall be performed on the whole conductor and the elongationmeasured when the first strand of the conductor br
12、eaks. Theminimum average elongation shall not be less than 10 % withno individual specimen less than 5 %.1This specification is under the jurisdiction of ASTM Committee B01 onElectrical Conductors and is the direct responsibility of Subcommittee B01.04 onConductors of Copper and Copper Alloys.Curren
13、t edition approved Oct. 1, 2007. Published October 2007. Originallyapproved in 1954. Last previous edition approved in 2002 as B 286 02.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume in
14、formation, refer to the standards Document Summary page onthe ASTM website.1Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.4.3.2 For stranded conductors larger than 22 AWG, strandsshall be carefully removed from the conductor and tes
15、ted forelongation. The minimum average elongation shall not be lessthan 10 % with no individual strand less than 5 %.4.4 D-C ResistanceThe d-c resistance in ohms per 1000 ftof annealed solid and stranded conductor shall not exceed,before insulating, the appropriate values prescribed in Table 1(Expla
16、natory Note 2).5. Conductor Construction5.1 Solid conductors shall conform to the requirements forType I conductors prescribed in Table 1.5.2 Stranded conductors shall conform to the requirementsfor Type II conductors prescribed in Table 1. The method ofstranding for conductor size designations 32-7
17、 through 10-104inclusive shall be at the option of the manufacturer unlessotherwise specified. Stranded conductors size designation 10-105 and larger shall normally be furnished in a rope-lay-stranded construction consisting of either 7 or 19 bunch-stranded members.6. Lay of Stranded Conductors6.1 T
18、he direction of lay of the outside layer of strandedconductors shall be left-hand. The direction of lay of thebunch-stranded members composing rope-lay-stranded con-ductors shall be at the option of the manufacturer unlessotherwise specified.6.2 The direction of lay of the outer layer of rope-lay-st
19、randed conductors shall be lefthand. The direction of lay ofthe other layers shall be reversed in successive layers, unlessotherwise specified.6.3 The length of lay of the outside layer of strandedconductors in size designation 32-7 through 10-104, inclusive,shall conform to the values in Table 1 (E
20、xplanatory Note 3).For strand constructions containing more than one distinctlayer the length of lay of the inner layer shall not exceed themaximum value shown in Table 1 for the conductor inquestion. For rope-lay-stranded conductors size designation10-105 and larger, and size 49/0.0142, the length
21、of lay of thewires composing the bunch-stranded members shall be notmore than 30 times the diameter of the member, and the lengthof lay of the outer layer of rope-lay-stranded conductors shallbe not less than 8 nor more than 16 times the outside diameterof the completed conductor.7. Joints7.1 Necess
22、ary joints in the individual wires of conductorssize designation 32-7 through size designation 10-104, inclu-sive, may be silver soldered, brazed, or butt welded. (Explana-tory Note 4). Bunch-stranded members composing ropelay-stranded conductors may be joined as a unit by brazing andthese joints sh
23、all be at least two lay lengths apart and befinished off so that the conductor diameter is not increased atthe joint. Disposition of joints throughout the conductor shallbe such that the diameter, configuration, conductor resistance,flexibility, and mechanical strength are not substantially af-fecte
24、d.8. Physical and Electrical Tests8.1 Tests to determine conformance of the coating to therequirements of Specifications B 33, B 189, B 298, or B 355shall be performed on Type I conductors before insulating andon the individual wires of Type II conductors before stranding.8.2 Tests to determine conf
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMB2862007STANDARDSPECIFICATIONFORCOPPERCONDUCTORSFORUSEINHOOKUPWIREFORELECTRONICEQUIPMENT 电气设备 连接线

链接地址:http://www.mydoc123.com/p-460866.html