ASTM B193-2002(2008) Standard Test Method for Resistivity of Electrical Conductor Materials《导电体材料电阻率的标准试验方法》.pdf
《ASTM B193-2002(2008) Standard Test Method for Resistivity of Electrical Conductor Materials《导电体材料电阻率的标准试验方法》.pdf》由会员分享,可在线阅读,更多相关《ASTM B193-2002(2008) Standard Test Method for Resistivity of Electrical Conductor Materials《导电体材料电阻率的标准试验方法》.pdf(5页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: B 193 02 (Reapproved 2008)Standard Test Method forResistivity of Electrical Conductor Materials1This standard is issued under the fixed designation B 193; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the year of las
2、t revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.This standard has been approved for use by agencies of the Department of Defense.1. Scope1.1 This test method covers the determinatio
3、n of the elec-trical resistivity of metallic electrical conductor material. Itprovides for an accuracy of 60.30 % on test specimens havinga resistance of 0.00001 V (10 V) or more. Weight resistivityaccuracy may be adversely affected by possible inaccuracies inthe assumed density of the conductor.1.2
4、 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use.2. Referenced Docu
5、ments2.1 ASTM Standards:2A 111 Specification for Zinc-Coated (Galvanized) “Iron”Telephone and Telegraph Line WireA 326 Specification for Zinc-Coated (Galvanized) HighTensile Steel Telephone and Telegraph Line Wire3B9 Specification for Bronze Trolley WireB 105 Specification for Hard-Drawn Copper Allo
6、y Wiresfor Electric ConductorsB 298 Specification for Silver-Coated Soft or AnnealedCopper WireB 355 Specification for Nickel-Coated Soft or AnnealedCopper WireB 415 Specification for Hard-Drawn Aluminum-Clad SteelWireB 566 Specification for Copper-Clad Aluminum WireB 800 Specification for 8000 Seri
7、es Aluminum Alloy Wirefor Electrical PurposesAnnealed and Intermediate Tem-pers2.2 NIST Document:NBS Handbook 100 Copper Wire Tables43. Resistivity3.1 Resistivity (Explanatory Note 1) is the electrical resis-tance of a body of unit length, and unit cross-sectional area orunit weight.3.2 Volume Resis
8、tivity is commonly expressed in ohms fora theoretical conductor of unit length and cross-sectional area;in inch-pound units in Vcmil/ft and in acceptable metric unitsin Vmm2/m. It may be calculated by the following equation:rv5 A/L!Rwhere:rv= volume resistivity, Vcmil/ft or Vmm2/m,A = cross-sectiona
9、l area, cmil or mm2,L = gage length, used to determine R,ftorm,andR = measured resistance, V.3.3 Weight Resistivity is commonly expressed in ohms for atheoretical conductor of unit length and weight. The methodfor calculating weight resistivity, based on resistance, length,and weight measurements, o
10、f a test specimen is given inExplanatory Note 2.4. Apparatus4.1 Resistance shall be measured with a circuit configura-tion and instrumentation that has a resistance measurementcapability of 60.15 % accuracy.5. Test Specimen5.1 The test specimen may be in the form of a wire, strip,rod, bar, tube, or
11、shape. It shall be of uniform cross sectionthroughout its length within 60.75 % of the cross-sectionalarea. Wherever possible it shall be the full cross section of thematerial it represents, if the full cross section is such that theuniformity of the cross-sectional area can be accurately deter-mine
12、d.5.2 The test specimen shall have the following characteris-tics:5.2.1 A resistance of at least 0.00001 V (10 V) in the testlength between potential contacts,1This test method is under the jurisdiction of ASTM Committee B01 onElectrical Conductors and is the direct responsibility of Subcommittee B0
13、1.02 onMethods of Test and Sampling Procedure.Current edition approved Sept. 1, 2008. Published September 2008. Originallyapproved in 1944. Last previous edition approved in 2002 as B 193 02.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serv
14、iceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.3Withdrawn4Available from National Institute of Standards and Technology (NIST), 100Bureau Dr., Stop 1070, Gaithersburg, MD 20899-1070, http:/www.nist.gov.1Copyright ASTM
15、 International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.5.2.2 A test length of at least 1 ft or 300 mm,5.2.3 A diameter, thickness, width, or other dimensionsuitable to the limitations of the resistance measuring instru-ment,5.2.4 No surface cracks or defe
16、cts visible to the unaidednormal eye, and substantially free from surface oxide, dirt, andgrease, and5.2.5 No joints or splices.6. Procedure6.1 Make all determinations of the dimensions and weightof the test specimen using instruments accurate to 60.05 %. Inorder to assure this accuracy in measuring
17、 the length betweenpotential contacts, the surface in contact with the test specimenshall be a substantially sharp knife-edge when using a Kelvin-type bridge or a potentiometer.6.2 The cross-sectional dimensions of the specimen may bedetermined by micrometer measurements, and a sufficientnumber of m
18、easurements shall be made to obtain the meancross section to within 60.10 %. In case any dimension of thespecimen is less than 0.100 in. and cannot be measured to therequired accuracy, determine the cross-section from the weight,density, and length of the specimen.6.3 When the density is unknown, de
19、termine the density byweighing a specimen first in air and then in a liquid of knowndensity at the test temperature, which shall be room tempera-ture to avoid errors due to convection currents. Exercise care inremoving all air bubbles from the specimen when weighing itin the liquid. Calculate the de
20、nsity from the following equa-tion:d5Wa3 d!/Wa2 Wl!where:d = density of the specimen, g/cm3;Wa= weight of the specimen in air, g;Wl= weight of the specimen in the liquid, g; andd = density of the liquid at the test temperature, g/cm3.6.4 When potential leads are used, make sure the distancebetween e
21、ach potential contact and the corresponding currentcontact is at least equal to 112 times the cross-sectionalperimeter of the specimen. Make sure the yoke resistance(between reference standard and test specimen) is appreciablysmaller than that of either the reference standard or the testspecimen unl
22、ess a suitable lead compensation method is used,or it is known that the coil and lead ratios are sufficientlybalanced so that variation in yoke resistance will not decreasethe bridge accuracy below stated requirements.6.5 Make resistance measurements to an accuracy of60.15 %. To ensure a correct rea
23、ding, allow the referencestandard and the test specimen to come to the same temperatureas the surrounding medium. (If the reference standard is madeof manganin it is possible to obtain correct readings with thetest specimen at reference temperatures other than roomtemperature). In all resistance mea
24、surements, the measuringcurrent raises the temperature of the medium. Therefore, takecare to keep the magnitude of the current low, and the time ofits use short enough so that the change in resistance cannot bedetected with the galvanometer. To eliminate errors due tocontact potential, take two read
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMB19320022008STANDARDTESTMETHODFORRESISTIVITYOFELECTRICALCONDUCTORMATERIALS 导电 材料 电阻率 标准 试验 方法 PDF

链接地址:http://www.mydoc123.com/p-460571.html